Validation of new pulsed Doppler echocardiographic techniques for assessment of pulmonary hemodynamics

Chest. 1993 May;103(5):1348-53. doi: 10.1378/chest.103.5.1348.

Abstract

In preparation for a vasodilator study on chronic obstructive pulmonary disease (COPD), we investigated the reliability of recently described pulsed Doppler techniques for estimating pulmonary artery pressure (PAP) and cardiac output (CO). Our aims were to determine the following: (1) the imaging success rate for pulsed Doppler measurements; (2) the repeatability of the measurements, and interobserver and intraobserver variability; and (3) the accuracy of Doppler compared with catheter measurements. Doppler studies were attempted in 81 patients (cardiac disease [23], COPD [22], sleep apnea [32], and normal subjects [4]). Suitable images were obtained in 68 subjects (84 percent) and in 76 subjects (94 percent) for PAP and CO estimations, respectively. The lowest imaging success rates were in COPD patients (68 percent for PAP and 86 percent for CO estimation). Repeatability of the techniques was assessed in four cardiac patients and three healthy volunteers by performing four replicate studies in each subject over 1 h. Intrasubject coefficient of variation was < 10 percent for PAP and < 5 percent for CO. The intraobserver variability for Doppler estimation of systolic and mean PAP was 5.5 percent and 5.8 percent, respectively. The corresponding values for interobserver variability were 6.7 percent and 6.2 percent. Intraobserver and interobserver variability for "nongeometric" method of estimating CO was 5.1 percent and 5.9 percent, respectively. Agreement was good between catheter-measured and Doppler-estimated PAP in the 27 patients tested (cardiac [19] and COPD [8]) for both mean and systolic pressures (r = 0.96 and r = 0.97, respectively). The correlations between thermodilution and Doppler estimations of CO in eight COPD patients were 0.77 ("geometric" technique) and 0.97 ("nongeometric" technique). We conclude that pulsed Doppler techniques can be used to obtain accurate and reproducible quantitative information on pulmonary hemodynamics in a wide range of patients. Suitable Doppler images can be obtained in more than two thirds of COPD patients.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Blood Pressure
  • Cardiac Output*
  • Echocardiography, Doppler / methods*
  • Female
  • Heart Diseases / diagnostic imaging
  • Heart Diseases / physiopathology
  • Humans
  • Lung Diseases, Obstructive / diagnostic imaging
  • Lung Diseases, Obstructive / physiopathology*
  • Male
  • Middle Aged
  • Observer Variation
  • Pulmonary Artery / diagnostic imaging
  • Pulmonary Artery / physiology*
  • Reproducibility of Results
  • Sleep Apnea Syndromes / diagnostic imaging
  • Sleep Apnea Syndromes / physiopathology