Fungal and endotoxin measurements in dust associated with respiratory symptoms in a water-damaged office building

Indoor Air. 2006 Jun;16(3):192-203. doi: 10.1111/j.1600-0668.2005.00415.x.

Abstract

We investigated the associations of fungal and endotoxin levels in office dust with respiratory health in 888 (67% participation) occupants of a water-damaged building. We analyzed floor and chair dusts from 338 workstations for culturable fungi and endotoxin. Based on averages, we ranked each floor of the building as low, medium, or high for occupants' exposure to each of these agents. Multivariate logistic regression models for building-related symptoms included this ranking of fungi and endotoxin, age, gender, race, smoking status, and duration of occupancy. Using floor dust measures, we found significantly increased odds for lower respiratory symptoms [wheeze, chest tightness, attacks of shortness of breath, and attacks of cough: odds ratios (OR) = 1.7 (95% confidence interval (CI): 1.02-2.77) to 2.4 (95% CI: 1.29-4.59)], throat irritation [OR = 1.7, (95% CI: 1.06-2.82)], and rash/itchy skin [OR = 3.0, (95% CI: 1.47-6.19)] in the highest fungal exposure group compared to the lowest, with generally linear exposure-response relationships. Nonlinear relationships were observed for many of these symptoms and endotoxin in floor dust. Interaction models showed that endotoxin modified effects of fungi on respiratory symptoms. Our findings of exposure interactions and exposure-response relationships of fungal and endotoxin with increased risk of building-related symptoms contribute to an understanding of the role of microbial agents in building-related asthma and respiratory and systemic symptoms.

Practical implications: Our demonstration of exposure-response relationships between measurements of fungi and/or endotoxin in floor dusts and building-related symptoms implies that microbial agents in floor dust may be a good surrogate measure for dampness-related bioaerosol exposure, considering that measurements of microbial agents in air often fail to demonstrate the associations between exposure and health. In addition, our finding that endotoxin exposure may change the effect of fungal exposure (and vice versa) on respiratory heath suggests that exposure to both fungi and endotoxin should be assessed in epidemiological investigations examining the effect of fungal or endotoxin exposure on respiratory health in indoor environments.

MeSH terms

  • Air Pollution, Indoor / analysis*
  • Antigens, Fungal / analysis*
  • Dust / analysis*
  • Endotoxins / analysis*
  • Environmental Monitoring / methods*
  • Epidemiological Monitoring
  • Fungi / isolation & purification*
  • Housing
  • Humans
  • Occupational Exposure
  • Respiratory Hypersensitivity / diagnosis
  • Respiratory Hypersensitivity / epidemiology
  • Respiratory Hypersensitivity / microbiology
  • Water

Substances

  • Antigens, Fungal
  • Dust
  • Endotoxins
  • Water