Variability in densitometric assessment of pulmonary emphysema with computed tomography

Invest Radiol. 2005 Dec;40(12):777-83. doi: 10.1097/01.rli.0000186418.31139.21.

Abstract

Objectives: The objectives of this study were to investigate whether computed tomography (CT) densitometry can be applied consistently in different centers; and to evaluate the reproducibility of densitometric quantification of emphysema by assessment of different sources of variation, ie, intersite, interscan and inter- and intraobserver variability, in comparison with intersubject variability.

Materials and methods: In 5 different hospitals, 119 patients with emphysema were scanned using standardized protocols. In each site, an observer performed a quantitative densitometric analysis (including blood recalibration) on the corresponding patient group (n=23-25) and one observer analyzed the entire group of 119 patients. After several months, the latter observer analyzed all data for a second time. Subsequently, different sources of variation were assessed by variance component analysis with and without volume correction of the data.

Results: Inter- and intraobserver variability marginally contributes to the total variability (<0.001%). The interscan variability was 0.02% of the total variation after application of volume correction. The intersite variability was 48% as a result of one deviating CT scanner. Air recalibration normalized deviating air densities in CT scanners. Within sites, the intersubject variability ranged between 93% and 99% based on the analysis of 2 subsequent CT scans of the patients.

Conclusions: Almost all variability in the density measurement of emphysema originates from differences between scanners and from differences in severity of emphysema between patients. Lung densitometry with multislice CT scanners is a highly reproducible measurement, especially if corrected for lung volume, because this reduces interscan variability.

Publication types

  • Clinical Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Absorptiometry, Photon / methods
  • Absorptiometry, Photon / statistics & numerical data*
  • Adult
  • Aged
  • Europe / epidemiology
  • Female
  • Humans
  • Incidence
  • Lung Volume Measurements / methods
  • Male
  • Middle Aged
  • Observer Variation
  • Pulmonary Emphysema / diagnostic imaging*
  • Pulmonary Emphysema / epidemiology*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods
  • Tomography, X-Ray Computed / statistics & numerical data*