Accuracy of echocardiographic right ventricular parameters in patients with different end-stage lung diseases prior to lung transplantation

J Heart Lung Transplant. 2000 Feb;19(2):145-54. doi: 10.1016/s1053-2498(99)00121-7.

Abstract

Background: Because there are few data available on the accuracy of 2D-echocardiography to assess right ventricular (RV) size and function in patients with far-advanced lung disease, in this prospective study, we compared various echocardiographic RV parameters with RV volumes derived from magnetic resonance imaging (MRI).

Methods: In 32 patients (18 male, 17 female) presenting for lung transplantation, we measured RV end-diastolic and end-systolic area as well as derived RV fractional area change, long-axis diameter, short-axis diameter, tricuspid valve anulus diameter (using 2D apical or sub-costal 4-chamber view), and RV end-diastolic diameter (using M-mode in the parasternal short-axis view). These values were compared with RV end-diastolic and end-systolic volumes derived by MRI, serving as the gold standard.

Results: Right ventricular end-diastolic area was the most accurate echocardiographic parameter of RV size (correlation to MRI: r = 0.88, p < 0.001), followed by RV end-diastolic short-axis diameter (r = 0.75, p < 0.001), long axis diameter (r = 0.66, p < 0.001), and tricuspid valve anulus diameter (r = 0.63, p < 0.001). In contrast, M-mode measurement of RV end-diastolic diameter was possible in only 24/35 (68%) patients and showed a weak correlation to MRI-derived RV end-diastolic volume (r = 0.56, p = 0.004). Right ventricular fractional area change correlated well with MRI-derived RV ejection fraction (r = 0.84, p < 0.0001). In a sub-group analysis, patients with vascular lung disease showed best agreement between both methods for RV end-diastolic area and RV fractional area change compared with patients with restrictive or obstructive lung disease.

Conclusion: This study shows that in patients with far-advanced lung diseases, RV end-diastolic area demonstrated the best correlation with MRI-derived measurement of RV end-diastolic volume, and RV fractional area change compared favorably with MRI-derived ejection fraction. Despite reduced image quality, especially in patients with obstructive lung disease, these parameters can yield clinically valuable information.

MeSH terms

  • Adult
  • Female
  • Heart Ventricles / diagnostic imaging*
  • Hemodynamics
  • Humans
  • Hypertrophy, Right Ventricular / diagnostic imaging
  • Lung Diseases / diagnostic imaging*
  • Lung Diseases / physiopathology
  • Lung Diseases / surgery
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Prospective Studies
  • Respiratory Function Tests
  • Stroke Volume
  • Ultrasonography
  • Ventricular Function, Right*