Table 2—

Lung function before and after exposure in a swine house# in subjects treated with placebo or fluticasone propionate

Subjects nPre-exposure VC % predPost-exposure ΔVC %Pre-exposure FEV1 % predPost-exposure ΔFEV1 %
Placebo889.1±10.0−3.6±2.9**95.1±7.3−7.8±4.1**
Fluticasone propionate797.1±7.9−1.9±1.5*99.9±12.0−4.9±2.6**
Between-group p-value0.40.4
  • Data are presented as mean±sd

  • There was no significant difference between the groups (t-test)

  • VC: vital capacity

  • Δ: change

  • FEV1: forced expiratory volume in one second

  • #: before medication and 7 h after exposure

  • : for 2 weeks prior to exposure

  • *: p<0.05

  • **: p<0.01 versus pre-exposure values