TY - JOUR T1 - Improvement of oxygen delivery in severe hypoxaemia by a reservoir cannula JF - European Respiratory Journal JO - Eur Respir J SP - 778 LP - 781 DO - 10.1183/09031936.93.02080778 VL - 2 IS - 8 AU - P Collard AU - F Wautelet AU - JP Delwiche AU - J Prignot AU - P Dubois Y1 - 1989/09/01 UR - http://erj.ersjournals.com/content/2/8/778.abstract N2 - In 36 severely hypoxaemic patients (arterial oxygen tension (PaO2) less than 7.3 kPa or 55 mmHg), candidates for long-term oxygen therapy, we compared the effectiveness of three oxygen-delivery systems, the standard nasal prongs, a so-called oxygen-conserving reservoir device ("Oxymizer Pendant") and the reference pharyngeal catheter, at a preset flow rate of 2 l.min-1. After 30 min, the conserving device (OX) was at least as efficient as the pharyngeal catheter (PC) and did significantly better than the nasal prongs (NP), the mean increments in PaO2 and arterial oxygen saturation (SaO2) being, respectively, 1.1 kPa (8.1 mmHg) and 1.3% higher with OX than with NP. Twenty patients did not reach the target level of 8.6 kPa (65 mmHg) PaO2 with the nasal prongs, but the reservoir cannula allowed nine of these "refractory" patients to hit this therapeutic goal, a result indicating a clear trend towards improved immediate oxygen response. Although initially designed to spare gas, we suggest that a reservoir cannula could serve another purpose, namely to optimize oxygenation in patients treated by an oxygen concentrator. Indeed, since the oxygen flow rate cannot be reliably increased over 3 l.min-1 with the available oxygen concentrators, the reservoir device could be more effective in some selected patients whose hypoxaemia cannot be adequately corrected by standard nasal prongs. ER -