A specific point-of-care screen for infectious pleural effusions using reagent strips
- *Depts of Internal Medicine
- #Laboratory Medicine, Pleural Diseases Unit, Arnau de Vilanova University Hospital, Unitat de Recerca Biomèdica de Lleida, Lleida, Spain
- J.M. Porcel, Dept of Internal Medicine, Arnau de Vilanova University Hospital, Avda Alcalde Rovira Roure 80, 25198 Lleida, Spain. E-mail: jporcelp{at}yahoo.es
To the Editors:
The timely diagnosis of infectious pleural effusions may be challenging [1]. Infection should be suspected in patients with radiographic pleural opacities and fever. However, fever is often present not only in parapneumonics, but also in tuberculous and, less commonly, other exudative effusions. Pleural fluid analysis is the appropriate tool to aid in the differential diagnosis, but it may not be available on an emergency basis.
The dipstick leukocyte esterase test is intended to detect leukocytes in urine, but it has also been applied to other biological specimens for the rapid diagnosis of infection. The test uses the ability of the esterase enzyme present in the polymorphonuclear leukocytes of the sample to split heterocyclic carboxylates and form a pyrrole. The latter reacts with a diazonium salt producing a violet colour in the reagent strip. We hypothesised that testing pleural fluid with leukocyte esterase reagent strips may help to rule in or out a bacterial aetiology (mostly parapneumonic effusions) in just a few minutes. If this were the case, the test would be of interest to emergency departments, war-time military medical units and countries with limited medical facilities [2].
We prospectively evaluated all consecutive patients who underwent a diagnostic thoracentesis at the Arnau de Vilanova University Hospital (Lleida, Spain) from September 2009 to November 2010. The ethics committee approved the study and all patients gave written informed consent.
After the pleural tap, the fluid was sent for routine biochemical, microbiological and cytological analyses and immediately tested with Combi-Screen® (Analyticon Biotechnologies AG, Lichtenfels, Germany) reagent strips designed for urine, by an investigator blinded to the clinician diagnosis. Similarly, the clinicians were unaware of the dipstick results until the end of the study. A drop of non-centrifuged pleural fluid collected in heparinised tubes was applied to the leukocyte label of the reagent strip. Then the colour change was visually read against the colour scale on the container at precisely 2 min. The results were recorded as: 0 (no change), 1+, 2+ or 3+. The finding of 1+ or more was considered a positive test. The price of each strip was €0.32.
The aetiology of pleural effusions was established by standard clinical criteria [1]. Patients were divided into three groups, namely, nonmycobacterial infectious, tuberculous and noninfectious effusions. Complicated parapneumonic effusions refer to those non-purulent effusions associated with bacterial pneumonia which require a tube thoracostomy for cure. Empyema was defined as pus in the pleural space. Between-group comparisons of qualitative and quantitative variables were made by the Fischer exact test and Kruskal–Wallis test, respectively. The discriminative properties of reagent strips were evaluated using receiver operating characteristic curve analysis. We calculated measures of test efficacy, such as sensitivity, specificity and likelihood ratios (LR). If the 2×2 contingency contained any zeros, resulting in likelihood estimates of zero or infinity, 0.5 was added to all the counts for calculating the LR and the respective confidence intervals. The correlation between semi-quantitative dipstick results and the number of leukocytes and neutrophils in the pleural fluid was performed using the Spearman correlation coefficient. In a small subgroup of patients, weighted κ was used to assess the level of agreement on dipstick readings.
Out of 145 patients recruited during the study period, 17 were excluded due to the presence of extremely bloody fluids, which make test strips uninterpretable, or because of an uncertain cause of the pleural effusion. The aetiological distribution of the final 128 pleural effusion patients, of whom 85 were males and 43 females with a median (quartiles) age of 69 (50–81) yrs, were as follows: 42 infectious (34 parapneumonics and eight non-parapneumonics), 15 tuberculous and 71 noninfectious fluids. The pleural fluid culture was positive in six patients from the first group (three parapneumonics and three non-parapneumonic infections). Pleural fluid reagent strip analysis is presented in table 1. The diagnostic performance of the leukocyte esterase for identifying nonmycobacterial infections against the remaining causes of pleural effusion was: sensitivity 42% (95% CI 27–57%); specificity 100% (95% CI 97–100%); positive LR 74.8 (95% CI 4.6–1212); negative LR 0.57 (95% CI 0.44–0.74); and area under the curve 0.71 (95% CI 0.61–0.82). In parapneumonic effusions, test sensitivity was unrelated to the infectious stage, whether simple, complicated or empyema. The positivity of reagent strips correlated with the number of neutrophils (r = 0.591, p<0.001) and leukocytes (r = 0.584, p<0.001) in the pleural fluid. Finally, the two-observer inter-rater agreement for the last 22 dipstick readings produced a κ statistic of 0.95 (0.89–0.99, p<0.001).
It was found that leukocyte esterase activity testing by dipstick may help rule in a nonmycobacterial infectious effusion due to its high specificity. The overall discriminatory properties of this simple and cheap test compare favourably with those of some biomarkers of pleural infection in use, such as C-reactive protein [1]. Only two previous studies have evaluated the ability of urine test strips when applied to pleural fluid specimens for identifying infectious effusions [3, 4]. However, they were performed on very selected populations. In the first study, Azoulay et al. [3] tested commercially available reagent strips (Multistix 8SG®; Bayer, Leverkusen, Germany) on 78 patients who had been admitted to an intensive care unit, including 35 with infectious effusions, 23 with noninfectious exudates and 20 transudates. A leukocyte esterase grade ≥2 on a six-grade scale, read by a colorimeter, displayed a sensitivity of 42%, specificity of 91%, positive LR of 4.9 and negative LR of 0.63 for the detection of infectious effusions among exudates. Nevertheless, the infectious group was a mixture of two tuberculous pleuritis, 21 parapneumonic and 14 empyema patients. Most importantly, 12 out of the 15 patients with infectious effusions and a leukocyte esterase test result grade of ≥2 had empyemas (defined as a positive pleural fluid culture). The plausible purulent appearance of most of these empyemas would have made the diagnosis clear without the use of reagent strips. In the second study, Castellote et al. [4] evaluated the performance of a reagent strip for leukocyte esterase (Aution®; Menarini Diagnostics, Firenze, Italy) to diagnose spontaneous bacterial pleuritis in 47 pleural fluid samples from patients with hepatic hydrothorax. When a test result cut-off of ≥2 on a five-grade scale was considered positive, reagent strips exhibited the following accuracy: sensitivity 91%, specificity 80%, positive LR 4.58 and negative LR 0.10. However, if the cut-off was set at ≥3, these figures were 83%, 100%, 58.1 and 0.17, respectively. Our study extends the applicability of dipstick tests to all patients with pleural effusion admitted to a general ward and notably reveals the negativity of reagent strips in pleural tuberculosis.
This study should be interpreted in the light of certain limitations. First, we used a visual reading rather than a colorimeter to make dipsticks more clinically applicable at the expense of a potentially less accurate interpretation. Extremely bloody fluids (>50,000 red blood cells·μL−1), an appearance which is present in 14% of 423 parapneumonics and 4% of 239 tuberculous effusions according to our unpublished database, preclude adequate recognition of colour field changes. Secondly, reagent strips did not discriminate between complicated and uncomplicated parapneumonic effusion, which is a more clinically relevant concern than the infectious or noninfectious differentiation. Thirdly, it seems unlikely that this test would be able to separate parapneumonic effusions from other neutrophil-rich effusions, including the 10% of tuberculous pleuritis which have this characteristic [5]. Because of the absence of such a comparator group in our series, further confirmatory studies are needed. Finally, it should be stressed that reagent strips should not be viewed as a substitute for biochemical analysis.
To conclude, reagent strips may speed up the bedside diagnosis of infectious effusions. As the value of a diagnostic test lies in its ability to distinguish between otherwise commonly confused disorders, it is thought by the authors that the main application for this use of dipsticks is bacterial-mycobacterial effusion discrimination, particularly in the setting of resource-limited healthcare systems. However, where access to standard biochemical pleural fluid analysis, including adenosine deaminase [5], is available, dipstick tests add little value to current practice.