Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions

Non-asphyxiating tracheobronchial foreign bodies in adults

RS Lan
European Respiratory Journal 1994 7: 510-514; DOI: 10.1183/09031936.94.07030510
RS Lan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

The presentations of 47 adult patients with a non-asphyxiating tracheobronchial foreign body were reviewed. The duration of residence of the foreign body was 1 week or less in nine ("acute group"); 1 month or more in 29 ("chronic group"), uncertain in four ("uncertain group"); and the foreign body was a broncholith in five patients ("broncholith group"). In the chronic and uncertain groups, no precipitating factor was found and bone was the most common foreign body. In the chronic group, a choking history was obtained before bronchoscopy in only 15 patient. Clinical manifestations and roentgenograms were nonspecific in most cases, except in the acute group. In the chronic group, the mean duration of residence of the foreign body was 25.8 months. The diagnosis was delayed due to absence of a choking history and invisibility of the foreign body on chest films in 12, due to patient's ignorance in 14, due to physician's ignorance in 1, and due to previous unsuccessful retrieval attempts in 2 patients. The main indication for bronchoscopy in the acute group was a choking history or a visible foreign body on the chest film. In the chronic group, a choking history or conditions leading to "suspicion of an endobronchial lesion" were the main indications. The foreign body was removed with a fibreoptic bronchoscope in over 90% of patients. It is concluded that the most important diagnostic factor is a high clinical index of suspicion and that flexible fibreoptic bronchoscopy provides a valuable therapeutic option in selected conditions.

PreviousNext
Back to top
Vol 7 Issue 3 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Non-asphyxiating tracheobronchial foreign bodies in adults
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Non-asphyxiating tracheobronchial foreign bodies in adults
RS Lan
European Respiratory Journal Mar 1994, 7 (3) 510-514; DOI: 10.1183/09031936.94.07030510

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Non-asphyxiating tracheobronchial foreign bodies in adults
RS Lan
European Respiratory Journal Mar 1994, 7 (3) 510-514; DOI: 10.1183/09031936.94.07030510
Reddit logo Technorati logo Twitter logo Connotea logo Facebook logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Identifying early PAH biomarkers in systemic sclerosis
  • Viable virus aerosol propagation by PAP circuit leak
  • Ambulatory management of secondary spontaneous pneumothorax
Show more Original Articles

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society