Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions

HypAir FeNO: an electrochemical sensor

Cristina Ramos Hernández, Marta Núñez Fernández, Cecilia Mouronte-Roibas, Mar Mosteiro Añon, Alberto Fernández-Villar
European Respiratory Journal 2018 51: 1800164; DOI: 10.1183/13993003.00164-2018
Cristina Ramos Hernández
Pulmonary Dept, University Complex of Vigo, Neumo Vigo I+i, Insttituto de Investigación Sanitaria Galicia Sur (IISGS), Vigo, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: cristina.ramos.hernandez@sergas.es
Marta Núñez Fernández
Pulmonary Dept, University Complex of Vigo, Neumo Vigo I+i, Insttituto de Investigación Sanitaria Galicia Sur (IISGS), Vigo, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Cecilia Mouronte-Roibas
Pulmonary Dept, University Complex of Vigo, Neumo Vigo I+i, Insttituto de Investigación Sanitaria Galicia Sur (IISGS), Vigo, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mar Mosteiro Añon
Pulmonary Dept, University Complex of Vigo, Neumo Vigo I+i, Insttituto de Investigación Sanitaria Galicia Sur (IISGS), Vigo, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alberto Fernández-Villar
Pulmonary Dept, University Complex of Vigo, Neumo Vigo I+i, Insttituto de Investigación Sanitaria Galicia Sur (IISGS), Vigo, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

HypAir FeNO is an electrochemical sensor; there is no chemiluminescence NO device http://ow.ly/tmvX30irOO7

To the Editor:

We would like to congratulate Alcázar-Navarrete et al. [1] on their paper which was published in a recent issue of the European Respiratory Journal. The authors observed that persistent exhaled nitric oxide fraction (FeNO) values ≥20 ppb in clinically stable chronic obstructive pulmonary disease (COPD) outpatients are associated with a significantly higher risk of acute exacerbations of COPD (AECOPD). This kind of approach would certainly have significant consequences for the follow-up of COPD patients.

Nevertheless, although the authors stated that FeNO was measured with a chemiluminescence nitric oxide (NO) analyser, referring to a HypAir FeNO machine (Médisoft, Sorinnes, Belgium), this device actually has electrochemical-based analysis [2].

Chemiluminescence-based analysis is considered to be the gold standard technique for measuring FeNO. These analysers are fast responding, highly sensitive and specific for nitric oxide gas. However, several factors such as size, cost and frequent calibration limit their permeation into routine clinical practice. To overcome these limitations electrochemical sensors have recently been developed and incorporated into hand-held measuring devices, but hand-held devices are not interchangeable so this information needs to be considered when these devices are used either for research purposes or for clinical practice [3, 4]. The well-established chemiluminescence-based NIOX (Aerocrine, Solna, Sweden) analysers are much more commonly used and most of the other devices give similar results [5], but measurements on the HypAir FeNO are 1.6 times (95% CI 1.11–2.05) higher than those obtained with the NIOX device. Therefore, a conversion factor is required if results are going to be compared with chemiluminescence devices [6] and it would be necessary if the results of the study want to be extrapolated to other centres.

A proper calibration and the possibility to show the plateau value ensure the reliability and accuracy of test results. HypAir FeNO allows real-time monitoring assuring that the value of FeNO has been obtained from manoeuvers with acceptability criteria. The manufacturer just recommends that the HypAir FeNO should be calibrated every 6 months with a 100 ppb NO gas, there are no instructions concerning regular zero calibration checking. A reliable NO-free calibration gas is essential for NO and the current American Thoracic Society/European Respiratory Society calibration recommendations are limited to ozone-/NO2-chemoluminescence-based analysers [6]. Lodge et al. [7] have developed a procedure that provides a pre-test check for the functioning of the NO scrubber in HypAir FeNO, and the paper by Alcázar-Navarrete et al. [1] does not report if this has been used as a routine quality control procedure.

Footnotes

  • Conflict of interest: None declared.

  • Received January 24, 2018.
  • Accepted January 29, 2018.
  • Copyright ©ERS 2018

References

  1. ↵
    1. Alcázar-Navarrete B,
    2. Ruiz Rodríguez O,
    3. Conde Baena P, et al.
    Persistently elevated exhaled nitric oxide fraction is associated with increased risk of exacerbation in COPD. Eur Respir J 2018; 51: 1701457.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    1. Maniscalc M,
    2. Vitale C,
    3. Vatrella A, et al.
    Fractional exhaled nitric oxide-measuring devices: technology update. Med Dev 2016; 9: 151–160.
    OpenUrl
  3. ↵
    1. Horváth I,
    2. Barnes PJ,
    3. Loukides S, et al.
    A European Respiratory Society technical standard: exhaled biomarkers in lung disease. Eur Respir J 2017; 49: 1600965.
    OpenUrlAbstract/FREE Full Text
  4. ↵
    American Thoracic Society, European Respiratory Society. ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005. Am J Respir Crit Care Med 2005; 171: 912–930.
    OpenUrlCrossRefPubMedWeb of Science
  5. ↵
    1. Korn S,
    2. Telke I,
    3. Kornmann O, et al.
    Measurement of exhaled nitric oxide: comparison of different analysers. Respirology 2010; 15: 203–1208.
    OpenUrl
  6. ↵
    1. Brooks CR,
    2. Brogan SM,
    3. Van Dalen CJ, et al.
    Measurement of exhaled nitric oxide in a general population sample: a comparison of the Medisoft HypAir FeNO and Aerocrine NIOX analyzers. J Asthma 2011; 48: 324–328.
    OpenUrlPubMed
  7. ↵
    1. Lodge CJ,
    2. Khalafzai RU,
    3. Dharmage SC, et al.
    Checking zero calibration of the HypAir FeNO. Am J Respir Crit Care Med 2010; 182: 719–720.
    OpenUrlPubMed
PreviousNext
Back to top
View this article with LENS
Vol 51 Issue 4 Table of Contents
European Respiratory Journal: 51 (4)
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
HypAir FeNO: an electrochemical sensor
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
HypAir FeNO: an electrochemical sensor
Cristina Ramos Hernández, Marta Núñez Fernández, Cecilia Mouronte-Roibas, Mar Mosteiro Añon, Alberto Fernández-Villar
European Respiratory Journal Apr 2018, 51 (4) 1800164; DOI: 10.1183/13993003.00164-2018

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
HypAir FeNO: an electrochemical sensor
Cristina Ramos Hernández, Marta Núñez Fernández, Cecilia Mouronte-Roibas, Mar Mosteiro Añon, Alberto Fernández-Villar
European Respiratory Journal Apr 2018, 51 (4) 1800164; DOI: 10.1183/13993003.00164-2018
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Footnotes
    • References
  • Info & Metrics
  • PDF

Subjects

  • COPD and smoking
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

Agora

  • Airway immune responses to COVID-19 vaccination in COPD patients
  • Wider access to rifapentine-based regimens is needed for TB care globally
  • Association between immunosuppressants and outcomes of COVID-19
Show more Agora

Correspondence

  • Reply to questions about FEV1Q and bronchodilator responsiveness
  • FEV1Q: it may be useful, but is it helpful?
  • Improving pulmonary function test interpretation
Show more Correspondence

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society