Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • For authors
    • Instructions for authors
    • Submit a manuscript
    • Author FAQs
    • Open access
    • COVID-19 submission information
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • For authors
    • Instructions for authors
    • Submit a manuscript
    • Author FAQs
    • Open access
    • COVID-19 submission information
  • Alerts
  • Podcasts
  • Subscriptions

A multicentre validation of the 1-min sit-to-stand test in patients with COPD

Sarah Crook, Gilbert Büsching, Konrad Schultz, Nicola Lehbert, Danijel Jelusic, Stephan Keusch, Michael Wittmann, Michael Schuler, Thomas Radtke, Martin Frey, Alexander Turk, Milo A. Puhan, Anja Frei
European Respiratory Journal 2017 49: 1601871; DOI: 10.1183/13993003.01871-2016
Sarah Crook
1Epidemiology, Biostatistics and Prevention Institute, Dept of Epidemiology, University of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: sarah.crook@uzh.ch
Gilbert Büsching
2Pulmonary Rehabilitation, Klinik Barmelweid, Barmelweid, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Konrad Schultz
3Centre for Rehabilitation, Pulmonology and Orthopaedics, Klinik Bad Reichenhall, Bad Reichenhall, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nicola Lehbert
3Centre for Rehabilitation, Pulmonology and Orthopaedics, Klinik Bad Reichenhall, Bad Reichenhall, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Danijel Jelusic
3Centre for Rehabilitation, Pulmonology and Orthopaedics, Klinik Bad Reichenhall, Bad Reichenhall, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephan Keusch
4Pulmonology, Zürcher RehaZentrum Wald, Wald, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Wittmann
3Centre for Rehabilitation, Pulmonology and Orthopaedics, Klinik Bad Reichenhall, Bad Reichenhall, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Schuler
5Dept of Medical Psychology, Medical Sociology and Rehabilitation Sciences, University of Würzburg, Würzburg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Radtke
1Epidemiology, Biostatistics and Prevention Institute, Dept of Epidemiology, University of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Frey
2Pulmonary Rehabilitation, Klinik Barmelweid, Barmelweid, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alexander Turk
4Pulmonology, Zürcher RehaZentrum Wald, Wald, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Milo A. Puhan
1Epidemiology, Biostatistics and Prevention Institute, Dept of Epidemiology, University of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anja Frei
1Epidemiology, Biostatistics and Prevention Institute, Dept of Epidemiology, University of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Our aim was to comprehensively validate the 1-min sit-to-stand (STS) test in chronic obstructive pulmonary disease (COPD) patients and explore the physiological response to the test.

We used data from two longitudinal studies of COPD patients who completed inpatient pulmonary rehabilitation programmes. We collected 1-min STS test, 6-min walk test (6MWT), health-related quality of life, dyspnoea and exercise cardiorespiratory data at admission and discharge. We assessed the learning effect, test–retest reliability, construct validity, responsiveness and minimal important difference of the 1-min STS test.

In both studies (n=52 and n=203) the 1-min STS test was strongly correlated with the 6MWT at admission (r=0.59 and 0.64, respectively) and discharge (r=0.67 and 0.68, respectively). Intraclass correlation coefficients (95% CI) between 1-min STS tests were 0.93 (0.83–0.97) for learning effect and 0.99 (0.97–1.00) for reliability. Standardised response means (95% CI) were 0.87 (0.58–1.16) and 0.91 (0.78–1.07). The estimated minimal important difference was three repetitions. End-exercise oxygen consumption, carbon dioxide output, ventilation, breathing frequency and heart rate were similar in the 1-min STS test and 6MWT.

The 1-min STS test is a reliable, valid and responsive test for measuring functional exercise capacity in COPD patients and elicited a physiological response comparable to that of the 6MWT.

Abstract

The 1-min STS test is a reliable, valid and responsive exercise capacity test in COPD with an MID of 3 repetitions http://ow.ly/teNx307ni0Q

Introduction

Commonly used and well-established exercise capacity tests in chronic obstructive pulmonary disease (COPD), such as the 6-min walk test (6MWT) [1] and incremental shuttle walk test [2] are not often assessed in inpatient, specialist outpatient or primary care settings due to the time, space and resources required to conduct them [3]. Since these settings are where most COPD patients are seen by practitioners, many patients are not able to have their exercise capacity assessed.

In recent years, research has begun to investigate the development of alternative tests that are simpler and easier to conduct. Tests have been proposed that measure a sit-to-stand (STS) movement, which is a movement commonly performed in everyday life. Two main types of STS tests have been developed that measure either the number of repetitions performed in a set time, such as the 1-min STS test, or the time taken to perform a set number of repetitions, such as the five-repetition (5)STS test [4]. Previous research has found cross-sectional 1-min STS test scores to correlate well with the 6MWT [3] and quadriceps muscle strength [5–7], and moderately with physical activity [8], indicating that the 1-min STS test may have cross-sectional validity as a measure of exercise capacity. The 1-min STS test also has potential as an important predictive tool, having shown predictive validity as a strong and independent predictor of mortality and health-related quality of life (HRQoL) in COPD patients [9].

While the 1-min STS test is increasingly used in studies of COPD patients [8, 10–16], its learning effect, reliability, responsiveness to change and minimal important difference (MID) have not yet been established in this patient population. Furthermore, little is known about the physiological response to the 1-min STS test in terms of the cardiorespiratory stress elicited. Therefore, our aims were to comprehensively validate the 1-min STS test in COPD patients by assessing the learning effect, test–retest reliability, construct cross-sectional and longitudinal validity, responsiveness to change and MID, and to examine the physiological response to the 1-min STS test and compare it with those of the 6MWT and 5STS test.

Methods

For the in-depth validation of the 1-min STS, we conducted the Validation of the 1-minute Sit-to-Stand Test in Patients with COPD (STAND-UP) study and used data from a subsample of the Routine Inspiratory Muscle Training Within COPD Rehabilitation (RIMTCORE) study for additional information on validity, responsiveness and MID. Both studies were approved by local ethics committees (Kantonale Ethikkommission Zürich (2014-0614), Ethikkommission Nordwest- und Zentralschweiz (2015-095) and Ethik-Kommission der Bayerischen Landesärztekammer (12107)). Exercise capacity, quadriceps strength, HRQoL, health status and symptoms were assessed at admission and discharge in COPD patients admitted to inpatient pulmonary rehabilitation. Further details on the methods are provided in the online supplementary material.

Study design, participants and measurements

STAND-UP study

STAND-UP is a prospective multicentre study conducted in two Swiss pulmonary rehabilitation clinics (Clinic Barmelweid and Zürcher RehaZentrum Wald) (ClinicalTrials.gov: NCT02441725). Exclusion criteria were lower limb joint surgery in the preceding 3 months, predominant neurological or musculoskeletal limitation to walking, and inability to do five repetitions in the 1-min STS test. Functional exercise capacity (1-min STS test, 5STS and 6MWT), quadriceps maximal voluntary contraction (QMVC), HRQoL and health status (Chronic Respiratory Questionnaire (CRQ) [17, 18], COPD Assessment Test (CAT) [19] and feeling thermometer [20]) and symptoms (Hospital Anxiety and Depression Scale (HADS) [21] and Baseline and Transition Dyspnoea Indexes (BDI and TDI, respectively)) [22] were assessed at admission and discharge. All patients, except those unable to wear a face mask due to long-term oxygen therapy or other reasons, conducted additional exercise capacity tests using a metabolic cart (Cortex Metamax 3B, Leipzig, Germany) [23] measuring oxygen consumption (V′O2), carbon dioxide output (V′CO2), respiratory exchange ratio (RER), minute ventilation (V′E), tidal volume (VT), respiratory frequency (fR), heart rate (HR) and arterial oxygen saturation measured by pulse oximetry (SpO2) during rest, exercise and recovery.

1-min STS test protocol

All 1-min STS tests were performed according to a standardised protocol by trained study staff. We used a standard chair (height 46–48 cm) with a flat seat and no armrests, stabilised against a wall. Patients were asked to sit with their legs hip-width apart and flexed to 90°, with their hands stationary on the hips without using the hands or arms to assist movement. They were instructed to stand completely straight and touch the chair with their bottom when sitting, but that they need not sit fully back on the chair. Patients were asked to perform as many repetitions as possible in 1 min, and after 45 s were told “you have 15 s left until the test is over”.

RIMTCORE study

The RIMTCORE study is a randomised controlled trial (RCT) (German Clinical Trials Register: DRKS 00004609) to assess the impact of inspiratory muscle training in addition to standard pulmonary rehabilitation in 611 COPD patients from the German pulmonary rehabilitation clinic Bad Reichenhall. Further information and initial results have been published in abstract form [24]. We included 203 participants of the RIMTCORE study as a subsample who additionally completed the 1-min STS test at admission or discharge from pulmonary rehabilitation. The 1-min STS test was introduced as an additional assessment in the final third of the study, and from then on was routinely and consecutively assessed in all participants. Patients were assessed for exercise capacity (6MWT), HRQoL (CAT, St George's Respiratory Questionnaire (SGRQ) [25] and Clinical COPD Questionnaire (CCQ) [26]) and symptoms (Medical Research Council (MRC) dyspnoea scale [27] and BDI/TDI) at admission and discharge. The protocol for the 1-min STS test was similar to the STAND-UP study protocol.

Statistical analysis

Descriptive data were reported as mean±sd or numbers and proportions. We calculated intraclass correlation coefficients (ICCs) for random-effects models between consecutive 1-min STS tests (learning effect and test–retest reliability), Pearson correlation coefficients for 1-min STS test scores and change scores with measures previously validated in COPD patients (cross-sectional and longitudinal construct validity) and standardised response means (SRMs) for the 1-min STS test (responsiveness) [28]. We constructed a Bland–Altman plot to further assess test–retest reliability. The MID was estimated using a combination of anchor-based (linear regression with the 1-min STS change score as the dependent variable and anchor change score as the independent variable to derive a regression equation that estimates the change in 1-min STS test repetitions equivalent to the MID of the anchor) [29] and distribution-based (Cohen's effect size [30], empirical rule effect size [31] and standard error of measurement [32]) approaches. For the physiological response, breath-by-breath data were exported from the metabolic cart and averaged over 10 s. We calculated end-exercise values as the mean of the final 10 s of exercise for the 1-min STS test, the mean of the final 30 s for the 6MWT, and the mean of the final two breaths of exercise and the breath immediately after for the 5STS, using the breath-by-breath data due to the short exercise duration. We calculated rest values as 30-s averages between minutes 1:30 and 2:00 and recovery values as the final 30 s of recovery. For patients who performed a maximal cycle ergometry test at baseline, we calculated the mean HR at peak exercise during cycle ergometry, 1-min STS test and 6MWT. The required sample size for STAND-UP was calculated as 43 participants assuming a power of 0.9 to detect a difference of 4.4 (half the sd of 1-min STS test scores from a previous study) [9]. For the RIMTCORE subsample we performed a post hoc power calculation based on the sample size available for 1-min STS test change scores (n=188), giving an estimated power of 1.0. All analyses were conducted using Stata (version 14.1; StataCorp, College Station, TX, USA) and graphs produced using R (version 3.3.0; www.r-project.org).

Results

52 consecutive patients were included in the STAND-UP study and 48 patients completed follow-up assessments. Four patients withdrew from the study due to unwillingness to continue or early discharge. 203 patients were included as a subsample of the RIMTCORE study with data for both assessment points available for 188. Baseline characteristics for both studies are shown in table 1, and baseline, follow-up and change scores for the exercise capacity tests, QMVC and patient-reported outcomes are shown in table 2. After pulmonary rehabilitation, 1-min STS test scores improved by 3.6±4.1 (STAND-UP) and 4.0±4.3 (RIMTCORE).

View this table:
  • View inline
  • View popup
TABLE 1

Baseline characteristics of patients in the STAND-UP and RIMTCORE studies

View this table:
  • View inline
  • View popup
TABLE 2

Mean scores for exercise capacity tests, muscle strength test and patient-reported outcomes, at baseline and follow-up and change after pulmonary rehabilitation

Measurement properties

Learning effect and test–retest reliability

The mean increase in 1-min STS test scores at baseline (learning effect) was 0.8±2.2 repetitions and the ICC was 0.93 (95% CI 0.83–0.97). The mean difference between the two tests at follow-up (test–retest reliability) was 0.02±1.6 repetitions and the ICC was 0.99 (95% CI 0.97–1.00). A Bland–Altman plot for the difference in 1-min STS test scores at follow-up is shown in online supplementary figure S1.

Construct (convergent) validity

Correlation coefficients between the 1-min STS test and validation measures are presented in table 3, according to whether they fulfilled our a priori assumptions about strength of correlation. The magnitude of cross-sectional correlations between the 1-min STS test and exercise capacity tests (6MWT and 5STS) ranged from 0.59 to 0.70; QMVC and domains of HRQoL and health status instruments (CRQ, CAT, feeling thermometer, CCQ and SGRQ) ranged from 0.01 to 0.52; and symptoms instruments (HADS, BDI and MRC dyspnoea scale) ranged from 0.03 to 0.51. In most cases, correlations were stronger at discharge than admission. Longitudinal correlations for change scores were all <0.4.

View this table:
  • View inline
  • View popup
TABLE 3

Pearson correlation coefficients for the 1-min sit-to-stand (STS) test with other exercise capacity tests, muscle strength test and patient-reported outcomes at admission, discharge and change scores#

Responsiveness to change and MID

The SRM was 0.87 (95% CI 0.58–1.16) for STAND-UP and 0.91 (0.78–1.07) for the RIMTCORE subsample. The MID estimates are summarised in table 4. The anchor-based estimates were larger than the distribution-based estimates with the anchors feeling thermometer and TDI giving estimates of 3.19 and 2.11 repetitions, respectively. The distribution-based estimates were similar across both studies with estimates between 0.93 and 2.16 repetitions.

View this table:
  • View inline
  • View popup
TABLE 4

Anchor- and distribution-based estimates of the minimal important difference (MID) for the 1-min sit-to-stand (STS) test

Physiological response

21 patients performed an additional 1-min STS test and 5STS with cardiorespiratory gas analysis, and 15 of those performed the 6MWT in addition. Reasons for missing 6MWTs were technical problems with the metabolic cart (n=4), logistical problems (n=1) or unwillingness to wear the facemask (n=1). For the 21 patients, mean±sd age was 64.5±9.7 years, forced expiratory volume in 1 s was 47.3±14.2% predicted, body mass index was 23.5±5.0 kg·m−2 and 15 (71%) were male.

Table 5 summarises the physiological values at rest, end-exercise and recovery for each exercise capacity test. End-exercise cardiorespiratory parameters during the 1-min STS were comparable to those of the 6MWT (V′O2, V′CO2, RER, V′E, V′E, VT, fR and HR), whereas the end-exercise values for the 5STS were lower in comparison.

View this table:
  • View inline
  • View popup
TABLE 5

Physiological responses to the 1-min sit-to-stand (STS) test, five-repetition STS test and 6-min walk test (6MWT) at rest, during exercise and recovery

Figure 1 shows the course of V′O2 for individual patients before, during and after exercise. Figure 2 shows the individual patient courses of SpO2 and which of those patients experienced oxygen desaturation (decrease in SpO2 ≥4%) [33]. Based on end-exercise values, desaturation was detected after the 1-min STS test in seven out of 21 patients and after the 6MWT in 10 out of 15 patients. After visual inspection of SpO2 profiles during the 1-min STS test, we saw that SpO2 often continued to decline in the first minute after exercise (figure 2a). When using the lowest SpO2 value in the first minute after exercise, desaturation was detected in four additional patients (patients 8, 12, 15 and 21) for the 1-min STS test (figure 2a). Comparisons of HR and Borg scale scores between cycle ergometry, 1-min STS test and 6MWT are given in table 6. End-exercise HRs were higher in the cycle ergometry than in the 1-min STS test and 6MWT (122.5 (95% CI 111.0–133.9) beats·min−1 versus 107.0 (95% CI 100.6–113.0) beats·min−1 and 108.0 (95% CI 98.2–118.0) beats·min−1). Patients reported marginally higher dyspnoea (0–10 scale) in the 1-min STS test than in cycle ergometry (4.6 (95% CI 3.1–6.1) versus 3.7 (95% CI 3.1–4.3)) and comparable leg fatigue (3.7 (95% CI 2.6–4.8) versus 3.8 (95% CI 3.2–4.5)).

FIGURE 1
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1

Oxygen consumption (V′O2) profiles for individual patients in each exercise test during rest, exercise and recovery. a) 1-min sit-to-stand test; b) five-repetition sit-to-stand test; c) 6-min walk test. Grey areas represent the duration of the exercise period. Data are plotted as 10-s averages apart from in b) where breath-by-breath data are plotted during exercise. Numbers in the upper right-hand corners represent individual patients, for comparison.

FIGURE 2
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2

Arterial oxygen saturation measured by pulse oximetry (SpO2) profiles for individual patients in each exercise test during rest, exercise and recovery. a) 1-min sit-to-stand test and b) 6-min walk test. Grey areas represent the duration of the exercise period. Numbers in the lower right-hand corners represent individual patients, for comparison. Data are plotted as 10-s averages, apart from patients 3, 4 and 6 who have measurements each minute during rest and every 30 s during recovery. #: patient experienced oxygen desaturation with a decrease in SpO2 ≥4%.

View this table:
  • View inline
  • View popup
TABLE 6

Comparison of test scores, end-exercise heart rate, dyspnoea and leg fatigue during cycle ergometry, 1-min sit-to-stand (STS) test and 6-min walk test (6MWT) for patients who were assessed by cycle ergometry at baseline

Discussion

We found that the 1-min STS test showed very little learning effect and excellent test–retest reliability in COPD patients. Strong correlations with the 6MWT suggest good cross-sectional construct validity. The 1-min STS test was responsive to two different pulmonary rehabilitation programmes, and the MID for clinical practice was estimated as three repetitions. We also observed similar responses to the 1-min STS test and 6MWT in terms of end-exercise cardiorespiratory values.

This is the first study to thoroughly assess the measurement properties of the 1-min STS test in COPD patients. Our findings for cross-sectional validity of the 1-min STS test were in accordance with previous studies that also found moderate to strong correlations (r=0.47–0.75) with the 6MWT [5, 15] and with quadriceps strength (r=0.65) [5]. Many measures met our assumptions about strength of correlation, indicating good cross-sectional construct validity; however, the poor change score correlations with exercise capacity tests (<0.4) suggest that they may measure different aspects of exercise capacity that are not correlated over time. Our results showed that the 1-min STS test is responsive to pulmonary rehabilitation, in contrast with results seen previously [7] where only statistical significance testing was reported.

In the STAND-UP study we were able to assess the learning effect and test–retest reliability with repeated 1-min STS tests at each time point. We found an almost perfect ICC for test–retest reliability and a similar, albeit slightly lower, ICC for the learning effect. Based on the range of estimated MIDs and with more influence from the anchor-based estimates [29], we suggest an MID of three repetitions for COPD patients. Our results contrast with those seen in a population of cystic fibrosis patients, where a larger learning effect was seen (increase of eight repetitions) [34], and a higher MID of five repetitions was recommended. The cystic fibrosis patient population was younger (median (interquartile range (IQR)) age 29 (25.5–36.0) years) than our populations and performed considerably more repetitions (median (IQR) 56 (48.0–61.5)), which suggests that with higher exercise capacity, technique may have more impact on test score. In addition, COPD patients in the STAND-UP and RIMTCORE studies performed fewer repetitions compared to reference values from the general Swiss population for corresponding age categories based on the mean ages of the two studies (median (IQR) repetitions 45 (29–44) and 41 (33–48), respectively) [16].

Although the 1-min STS test and 6MWT involve different movements, they both elicited similar physiological responses. Quadriceps muscle strength is a known determinant of 6MWT performance [35, 36] and we observed comparable associations in our study for the 1-min STS test. This suggests that despite the differences in movements between the two tests, both heavily rely on quadriceps strength. While dyspnoea scores were comparable for the 1-min STS test and 6MWT, leg fatigue was rated 0.9 points higher for the 1-min STS test. We can only speculate that there is a greater perception of quadriceps muscle fatigue resulting from eccentric muscle contractions during the stand-to-sit phase of the 1-min STS test than the 6MWT [36]. In comparison to both the 1-min STS test and 6MWT, the 5STS did not elicit a strong cardiorespiratory response, most probably due to the very short test duration, suggesting that the usefulness of the 5STS for assessing exercise capacity may be limited.

We observed greater heterogeneity between individual patient V′O2 responses to the 1-min STS test than the 5STS, but were unable to identify potential reasons for this based on individual baseline characteristics. In our study, we observed a decrease in SpO2 during the 6MWT, similar to that seen in previous studies [37] (decrease of 7.2%); however, during the 1-min STS test we saw a decrease of 2.7% when calculated with end-exercise SpO2. This corresponds with previous studies that found a decrease in SpO2 of 1–2% in the 1-min STS test [5, 7]. This could be due to either the shorter duration of the 1-min STS test or the 6MWT requiring more muscles than the 1-min STS test and therefore resulting in a greater metabolic demand and oxygen consumption. However, in the 1-min STS test we observed that SpO2 often continued to decline in the first minute of recovery, and when using the lowest SpO2 value in this minute, we detected desaturation during the 1-min STS test in all patients who desaturated in the 6MWT. We suggest measuring SpO2 for 1 min after exercise if identification of desaturation is required. In the subsample of patients with maximal cycle ergometry data, we found that during the 1-min STS test patients achieved HR, dyspnoea and leg fatigue levels closer to those achieved in cycle ergometry than during the 6MWT. This shows the clinical relevance of the 1-min STS test, as the 6MWT is considered to be a good approximation of cycle ergometry in moderate to severe COPD [38].

One strength of our study is that we had data from two different COPD studies, one specifically designed to validate the 1-min STS test and one unrelated RCT, with different population characteristics and pulmonary rehabilitation programmes. This allows us to demonstrate the reproducibility of our results and that our findings can probably be applied to a wider COPD population. A further strength is that we were able to investigate all important measurement properties of the 1-min STS test in one study. Much consideration was put into designing the STAND-UP study to enable the assessment of all measurement properties while reducing as much bias and patient effort as possible. A limitation of our study is that there was a relatively large amount of missing data for the 6MWTs with cardiorespiratory gas analysis, although this was mainly due to technical problems and thus could be considered missing completely at random. An additional limitation is that we did not have maximal ergometry data for all patients and SpO2 at maximal exercise was missing for most of those who did, meaning we could not correlate this with 1-min STS test and 6MWT end-exercise SpO2. Another limitation of the STAND-UP study is that we excluded patients who were unable to perform at least five repetitions. Previous experience showed us that these patients were often limited by musculoskeletal or neurological problems not directly related to exercise capacity, and we generally assumed that fewer than five repetitions in 1 min would not be enough to see a meaningful exercise performance. The threshold of five repetitions is arbitrary to some extent and limits the generalisability of our results to patients who fulfil these criteria (i.e. those without musculoskeletal or neurological limitations and those with the poorest exercise performance).

For use in clinical practice, we have provided a protocol for conducting the 1-min STS test to ensure consistency. Clinicians can easily integrate the 1-min STS test into practice to evaluate interventions and general state of health of their patients over time, as we have provided a means to determine a clinically relevant difference. Although suitable for most patients, the 1-min STS test may not be suitable for very poorly functioning patients who are unable to perform a minimum number of repetitions (we suggest five). Due to the small learning effect observed, we recommend that the 1-min STS test be performed twice if applicable and that the higher score of these should be used when possible, particularly in research. However, since the learning effect was negligible, we suggest that performing the test once would still give reliable results.

In conclusion, the 1-min STS test proves to be a promising alternative to traditional exercise capacity tests in COPD patients. It is reliable, valid and responsive and showed a comparable end-exercise physiological response to the 6MWT. We recommend an MID of three repetitions. The 1-min STS test is suitable for use in clinical practice and research settings when traditional tests are not practical.

Supplementary material

Supplementary Material

Please note: supplementary material is not edited by the Editorial Office, and is uploaded as it has been supplied by the author.

supplement ERJ-01871-2016_supplement

Disclosures

Supplementary Material

G. Buesching ERJ-01871-2016_Buesching

S. Crook ERJ-01871-2016_Crook

A. Frei ERJ-01871-2016_Frei

D. Jelusic ERJ-01871-2016_Jelusic

N. Lehbert ERJ-01871-2016_Lehbert

M.A Puhan ERJ-01871-2016_Puhan

M. Schuler ERJ-01871-2016_Schuler

K. Schultz ERJ-01871-2016_Schultz

M. Wittmann ERJ-01871-2016_Wittmann

Acknowledgements

The authors thank Ioannis Vogiatzis (University of Athens, Athens, Greece) and Roberto Rabinovich (University of Edinburgh, Edinburgh, UK) for their advice and support in the planning of the assessments of the physiological response during the exercise tests. They also thank the study nurses Ursula Schafroth (University of Zurich, Zurich, Switzerland) and Luise Wiedemann (Zürcher RehaZentrum Wald, Faltigberg-Wald, Switzerland) for their work in the conduct of the study.

Footnotes

  • This article has supplementary material available from erj.ersjournals.com

  • Support statement: The Verein Lunge Zurich foundation (STAND-UP) and the Deutsche Rentenversicherung Bayern Süd (RIMTCORE). Funding information for this article has been deposited with the Open Funder Registry.

  • Conflict of interest: Disclosures can be found alongside this article at erj.ersjournals.com

  • Received September 22, 2016.
  • Accepted December 14, 2016.
  • Copyright ©ERS 2017

References

  1. ↵
    1. Sciurba F,
    2. Criner GJ,
    3. Lee SM, et al.
    Six-minute walk distance in chronic obstructive pulmonary disease: reproducibility and effect of walking course layout and length. Am J Respir Crit Care Med 2003; 167: 1522–1527.
    OpenUrlCrossRefPubMedWeb of Science
  2. ↵
    1. Singh SJ,
    2. Morgan MD,
    3. Scott S, et al.
    Development of a shuttle walking test of disability in patients with chronic airways obstruction. Thorax 1992; 47: 1019–1024.
    OpenUrlAbstract/FREE Full Text
  3. ↵
    1. Puhan MA,
    2. Zoller M,
    3. ter Riet G
    . COPD: more than respiratory. Lancet 2008; 371: 27–28.
    OpenUrlCrossRefPubMedWeb of Science
  4. ↵
    1. Jones SE,
    2. Kon SS,
    3. Canavan JL, et al.
    The five-repetition sit-to-stand test as a functional outcome measure in COPD. Thorax 2013; 68: 1015–1020.
    OpenUrlAbstract/FREE Full Text
  5. ↵
    1. Ozalevli S,
    2. Ozden A,
    3. Itil O, et al.
    Comparison of the sit-to-stand test with 6 min walk test in patients with chronic obstructive pulmonary disease. Respir Med 2007; 101: 286–293.
    OpenUrlCrossRefPubMed
    1. Rausch-Osthoff AK,
    2. Kohler M,
    3. Sievi NA, et al.
    Association between peripheral muscle strength, exercise performance, and physical activity in daily life in patients with chronic obstructive pulmonary disease. Multidiscip Respir Med 2014; 9: 37.
    OpenUrlPubMed
  6. ↵
    1. Zanini A,
    2. Aiello M,
    3. Cherubino F, et al.
    The one repetition maximum test and the sit-to-stand test in the assessment of a specific pulmonary rehabilitation program on peripheral muscle strength in COPD patients. Int J Chron Obstruct Pulmon Dis 2015; 10: 2423–2430.
    OpenUrl
  7. ↵
    1. van Gestel AJR,
    2. Clarenbach CF,
    3. Stöwhas AC, et al.
    Predicting daily physical activity in patients with chronic obstructive pulmonary disease. PLoS One 2012; 7: e48081.
    OpenUrlCrossRefPubMed
  8. ↵
    1. Puhan MA,
    2. Siebeling L,
    3. Zoller M, et al.
    Simple functional performance tests and mortality in COPD. Eur Respir J 2013; 42: 956–963.
    OpenUrlAbstract/FREE Full Text
  9. ↵
    1. Bisca GW,
    2. Morita AA,
    3. Hernandes NA, et al.
    Simple lower limb functional tests in patients with chronic obstructive pulmonary disease: a systematic review. Arch Phys Med Rehabil 2015; 96: 2221–2230.
    OpenUrlCrossRefPubMed
    1. Albores J,
    2. Marolda C,
    3. Haggerty M, et al.
    The use of a home exercise program based on a computer system in patients with chronic obstructive pulmonary disease. J Cardiopulm Rehabil Prev 2013; 33: 47–52.
    OpenUrlCrossRefPubMed
    1. Normandin EA,
    2. McCusker C,
    3. Connors M, et al.
    An evaluation of two approaches to exercise conditioning in pulmonary rehabilitation. Chest 2002; 121: 1085–1091.
    OpenUrlCrossRefPubMedWeb of Science
    1. Grosbois JM,
    2. Gicquello A,
    3. Langlois C, et al.
    Long-term evaluation of home-based pulmonary rehabilitation in patients with COPD. Int J Chron Obstruct Pulmon Dis 2015; 10: 2037–2044.
    OpenUrl
    1. Yumrutepe T,
    2. Aytemur ZA,
    3. Baysal O, et al.
    Relationship between vitamin D and lung function, physical performance and balance on patients with stage I-III chronic obstructive pulmonary disease. Rev Assoc Med Bras 2015; 61: 132–138.
    OpenUrl
  10. ↵
    1. Meriem M,
    2. Cherif J,
    3. Toujani S, et al.
    Sit-to-stand test and 6-min walking test correlation in patients with chronic obstructive pulmonary disease. Ann Thorac Med 2015; 10: 269–273.
    OpenUrl
  11. ↵
    1. Strassmann A,
    2. Steurer-Stey C,
    3. Lana KD, et al.
    Population-based reference values for the 1-min sit-to-stand test. Int J Public Health 2013; 58: 949–953.
    OpenUrl
  12. ↵
    1. Puhan MA,
    2. Behnke M,
    3. Laschke M, et al.
    Self-administration and standardisation of the chronic respiratory questionnaire: a randomised trial in three German-speaking countries. Respir Med 2004; 98: 342–350.
    OpenUrlCrossRefPubMedWeb of Science
  13. ↵
    1. Wijkstra PJ,
    2. TenVergert EM,
    3. Van Altena R, et al.
    Reliability and validity of the chronic respiratory questionnaire (CRQ). Thorax 1994; 49: 465–467.
    OpenUrlAbstract/FREE Full Text
  14. ↵
    1. Jones PW,
    2. Harding G,
    3. Berry P, et al.
    Development and first validation of the COPD Assessment Test. Eur Respir J 2009; 34: 648–654.
    OpenUrlAbstract/FREE Full Text
  15. ↵
    1. Schünemann HJ,
    2. Griffith L,
    3. Jaeschke R, et al.
    Evaluation of the minimal important difference for the feeling thermometer and the St. George's Respiratory Questionnaire in patients with chronic airflow obstruction. J Clin Epidemiol 2003; 56: 1170–1176.
    OpenUrlCrossRefPubMedWeb of Science
  16. ↵
    1. Snaith RP
    . The Hospital Anxiety and Depression Scale. Health Qual Life Outcomes 2003; 1: 29.
    OpenUrlCrossRefPubMed
  17. ↵
    1. Witek TJ,
    2. Mahler DA
    . Minimal important difference of the transition dyspnoea index in a multinational clinical trial. Eur Respir J 2003; 21: 267–272.
    OpenUrlAbstract/FREE Full Text
  18. ↵
    1. Macfarlane DJ,
    2. Wong P
    . Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system. Eur J Appl Physiol 2012; 112: 2539–2547.
    OpenUrlCrossRefPubMed
  19. ↵
    1. Schultz K,
    2. Krämer B,
    3. Fuchs S, et al.
    Effects of routine inspiratory muscle training (IMT) as add-on to pulmonary rehabilitation (PR) in COPD. Eur Respir J 2015; 46: Suppl. 59, PA544.
    OpenUrl
  20. ↵
    1. Jones PW,
    2. Quirk FH,
    3. Baveystock CM
    . The St George's Respiratory Questionnaire. Respir Med 1991; 85: Suppl. B, 25–31.
    OpenUrlCrossRefPubMedWeb of Science
  21. ↵
    1. van der Molen T,
    2. Willemse BW,
    3. Schokker S, et al.
    Development, validity and responsiveness of the Clinical COPD Questionnaire. Health Qual Life Outcomes 2003; 1: 13.
    OpenUrlCrossRefPubMed
  22. ↵
    1. Bestall JC,
    2. Paul EA,
    3. Garrod R, et al.
    Usefulness of the Medical Research Council (MRC) dyspnoea scale as a measure of disability in patients with chronic obstructive pulmonary disease. Thorax 1999; 54: 581–586.
    OpenUrlAbstract/FREE Full Text
  23. ↵
    1. McCarthy B,
    2. Casey D,
    3. Devane D, et al.
    Pulmonary rehabilitation for chronic obstructive pulmonary disease. Cochrane Database Syst Rev 2015; 2: CD003793.
    OpenUrlPubMed
  24. ↵
    1. Guyatt GH,
    2. Osoba D,
    3. Wu AW, et al.
    Methods to explain the clinical significance of health status measures. Mayo Clin Proc 2002; 77: 371–383.
    OpenUrlCrossRefPubMedWeb of Science
  25. ↵
    1. Walters SJ,
    2. Brazier JE
    . What is the relationship between the minimally important difference and health state utility values? The case of the SF-6D. Health Qual Life Outcomes 2003; 1: 4.
    OpenUrlCrossRefPubMed
  26. ↵
    1. Sloan JA,
    2. Dueck A
    . Issues for statisticians in conducting analyses and translating results for quality of life end points in clinical trials. J Biopharm Stat 2004; 14: 73–96.
    OpenUrlCrossRefPubMed
  27. ↵
    1. Wyrwich KW,
    2. Tierney WM,
    3. Wolinsky FD
    . Further evidence supporting an SEM-based criterion for identifying meaningful intra-individual changes in health-related quality of life. J Clin Epidemiol 1999; 52: 861–873.
    OpenUrlCrossRefPubMedWeb of Science
  28. ↵
    1. Poulain M,
    2. Durand F,
    3. Palomba B, et al.
    6-minute walk testing is more sensitive than maximal incremental cycle testing for detecting oxygen desaturation in patients with COPD. Chest 2003; 123: 1401–1407.
    OpenUrlCrossRefPubMedWeb of Science
  29. ↵
    1. Radtke T,
    2. Puhan MA,
    3. Hebestreit H, et al.
    The 1-min sit-to-stand test – a simple functional capacity test in cystic fibrosis? J Cyst Fibros 2016; 15: 223–226.
    OpenUrl
  30. ↵
    1. Singer J,
    2. Yelin EH,
    3. Katz PP, et al.
    Respiratory and skeletal muscle strength in chronic obstructive pulmonary disease: impact on exercise capacity and lower extremity function. J Cardiopulm Rehabil Prev 2011; 31: 111–119.
    OpenUrlCrossRefPubMed
  31. ↵
    1. Butcher SJ,
    2. Pikaluk BJ,
    3. Chura RL, et al.
    Associations between isokinetic muscle strength, high-level functional performance, and physiological parameters in patients with chronic obstructive pulmonary disease. Int J Chron Obstruct Pulmon Dis 2012; 7: 537–542.
    OpenUrlPubMed
  32. ↵
    1. van Gestel AJR,
    2. Clarenbach CF,
    3. Stöwhas AC, et al.
    Prevalence and prediction of exercise-induced oxygen desaturation in patients with chronic obstructive pulmonary disease. Respiration 2012; 84: 353–359.
    OpenUrlCrossRefPubMedWeb of Science
  33. ↵
    1. Singh SJ,
    2. Puhan MA,
    3. Andrianopoulos V, et al.
    An official systematic review of the European Respiratory Society/American Thoracic Society: measurement properties of field walking tests in chronic respiratory disease. Eur Respir J 2014; 44: 1447–1478.
    OpenUrlAbstract/FREE Full Text
View Abstract
PreviousNext
Back to top
View this article with LENS
Vol 49 Issue 3 Table of Contents
European Respiratory Journal: 49 (3)
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A multicentre validation of the 1-min sit-to-stand test in patients with COPD
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Alerts
Sign In to Email Alerts with your Email Address
Citation Tools
A multicentre validation of the 1-min sit-to-stand test in patients with COPD
Sarah Crook, Gilbert Büsching, Konrad Schultz, Nicola Lehbert, Danijel Jelusic, Stephan Keusch, Michael Wittmann, Michael Schuler, Thomas Radtke, Martin Frey, Alexander Turk, Milo A. Puhan, Anja Frei
European Respiratory Journal Mar 2017, 49 (3) 1601871; DOI: 10.1183/13993003.01871-2016

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
A multicentre validation of the 1-min sit-to-stand test in patients with COPD
Sarah Crook, Gilbert Büsching, Konrad Schultz, Nicola Lehbert, Danijel Jelusic, Stephan Keusch, Michael Wittmann, Michael Schuler, Thomas Radtke, Martin Frey, Alexander Turk, Milo A. Puhan, Anja Frei
European Respiratory Journal Mar 2017, 49 (3) 1601871; DOI: 10.1183/13993003.01871-2016
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Abstract
    • Introduction
    • Methods
    • Results
    • Discussion
    • Supplementary material
    • Disclosures
    • Acknowledgements
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Subjects

  • COPD and smoking
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

Original Articles

  • The impact of COVID-19 on patients with asthma
  • FEV1 decline and cardiovascular disease in COPD
  • HIF2α-ARNT hetero-dimerisation as a therapeutic strategy for PAH
Show more Original Articles

COPD

  • FEV1 decline and cardiovascular disease in COPD
  • OSTEOPOROSIS AND FACTURE RISK ASSOCIATED WITH ICS USE IN COPD
  • Should the number of acute exacerbations in the previous year be used to guide treatments in COPD?
Show more COPD

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • CME
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Submit a manuscript
  • ERS author centre

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2021 by the European Respiratory Society