Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions

Should use of 4 hours continuous positive airway pressure per night be considered acceptable compliance?

Juan F. Masa, Jaime Corral-Peñafiel
European Respiratory Journal 2014 44: 1119-1120; DOI: 10.1183/09031936.00121514
Juan F. Masa
1Dept of Pneumology, San Pedro de Alcantara Hospital, Caceres, Spain
2CIBER de enfermedades respiratorias (CIBERES), Madrid, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: fmasa@separ.es
Jaime Corral-Peñafiel
1Dept of Pneumology, San Pedro de Alcantara Hospital, Caceres, Spain
2CIBER de enfermedades respiratorias (CIBERES), Madrid, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Continuous positive airway pressure (CPAP) reduces blood pressure in obstructive sleep apnoea (OSA) patients, as well as in patients with resistant hypertension. The effect of CPAP is directly related to treatment compliance [1–3]. Observational studies have shown a reduction in cardiovascular mortality risk in severe OSA patients treated with CPAP and adequate compliance [4–6]. A recent randomised controlled trial (RCT) showed a reduction in cardiovascular events (including hypertension incidence) in patients with adequate CPAP compliance [7]. However, what is an adequate definition of CPAP compliance?

Ideally, CPAP compliance should take place for as long as the patient is sleeping but, in practice, this occurs in a minority of subjects. Based on several studies, compliance of ≥4 h per night has been considered acceptable. However, dose–response studies have found that different compliance levels achieve different dimensions of clinical improvement [8–11]. For instance, in order to obtain an improvement in Epworth sleepiness scale at least 4 h·night−1 of CPAP is required [8], 6 h·night−1 is required for multiple sleep latency test and memory [8, 11] and 7.5 h·night−1 for functional outcome associated with a sleepiness questionnaire [8]. Therefore, is there a CPAP compliance level to obtain a reduction in cardiovascular risk?

There is little information about the necessary CPAP compliance needed to decrease cardiovascular risk. In an observational study, cardiovascular mortality was reduced in OSA patients with CPAP compliance of ≥4 h·night−1 [4]. In another observational study, mortality (mainly from cardiovascular causes) decreased with night-time CPAP use of 1–6 h·night−1 but decreased more acutely with a compliance of ≥6 h·night−1 [5]. In a recent RCT, reduction of blood pressure in OSA patients with hypertension required 5.6 h·night−1 of CPAP [2] and compliance of 5.96 h·night−1 decreased the incidence cardiovascular events (including hypertension) [7].

Several studies have explored potential CPAP compliance improvement by adding simple or combined strategies to the standard management [12–17]. Accordingly, CPAP use increased in >1 h·night−1 producing clinical improvement. In this issue of the European Respiratory Journal, Bouloukaki et al. [18] present results from the largest RCT on this topic comparing the effect of multidimensional versus standard strategies on CPAP compliance for 2 years of follow-up. The authors randomised 3100 newly diagnosed OSA patients to the standard group or the intensive group. Night-time CPAP use improved on average by >1.7 h with the multidimensional intervention than with the standard one. This resulted in an important clinical improvement but the most significant data showed that cardiovascular event incidence decreased by 50%. Hospitalisations due to new cardiovascular events occurred in 45 (2.9%) patients in the multidimensional strategy and in 96 (6.2%) in the standard strategy. From these, fatal events occurred in 1.8% and in 4% of patients, respectively. To put these data into perspective, we present the results of the study by Marin et al. [4]. Cardiovascular incidence for 2 years was 1.28% and cardiovascular mortality was 0.7% for patients with severe OSA with ≥4 h of CPAP use. Although these data seem lower than in the study by Bouloukaki et al. [18], in another large RCT the subgroup with better CPAP compliance (5.96 h·night−1) had an estimated cardiovascular incidence (without hypertension incidence) of 7.3% for 2 years [7].

In the study by Bouloukaki et al. [18], the multidimensional intervention was an independent factor used to explain cardiovascular mortality reduction. This means that an increase of 1.7 h·night−1 resulted in a survival improvement. In addition, another independent factor of mortality was CPAP use for <6 h·night−1; although more interesting data could be a dose–response analysis to determine what CPAP compliance level would result in a survival improvement.

Another important aspect of the study by Bouloukaki et al. [18] was the economical evaluation, which took into account the intervention burden and the economical saving caused by the prevention of hospital admissions due to cardiovascular problems. This resulted in an incremental burden of €100 with a saving of €41 713. Unfortunately, the study was not designed to analyse cost-effectiveness. It is very important to transfer the results from clinical research assessing efficacy directly into healthcare systems and the public.

In summary, the present study shows that achieving better CPAP compliance using an active intervention decreases cardiovascular mortality and suggests CPAP use of ≥6 h·night−1. Future studies using dose–response evaluation and cost-effectiveness analysis would be welcomed

Footnotes

  • Conflict of interest: None declared.

  • Received July 2, 2014.
  • Accepted July 18, 2014.
  • ©ERS 2014

References

  1. ↵
    1. Martínez-García MA,
    2. Capote F,
    3. Campos-Rodríguez F,
    4. et al
    . Effect of CPAP on blood pressure in patients with obstructive sleep apnea and resistant hypertension: the HIPARCO randomized clinical trial. JAMA 2013; 310: 2407–2415.
    OpenUrlPubMedWeb of Science
  2. ↵
    1. Barbé F,
    2. Durán-Cantolla J,
    3. Capote F,
    4. et al
    . Long-term effect of continuous positive airway pressure in hypertensive patients with sleep apnea. Am J Respir Crit Care Med 2010; 181: 718–726.
    OpenUrlCrossRefPubMedWeb of Science
  3. ↵
    1. Haentjens P,
    2. Van Meerhaeghe A,
    3. Moscariello A,
    4. et al
    . The impact of continuous positive airway pressure on blood pressure in patients with obstructive sleep apnea syndrome: evidence from a meta-analysis of placebo-controlled randomized trials. Arch Intern Med 2007; 167: 757–764.
    OpenUrlCrossRefPubMedWeb of Science
  4. ↵
    1. Marin JM,
    2. Carrizo SJ,
    3. Vicente E,
    4. et al
    . Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet 2005; 365: 1046–1053.
    OpenUrlCrossRefPubMedWeb of Science
  5. ↵
    1. Campos-Rodriguez F,
    2. Martinez-Garcia MA,
    3. de la Cruz-Moron I,
    4. et al
    . Cardiovascular mortality in women with obstructive sleep apnea with or without continuous positive airway pressure treatment: a cohort study. Ann Intern Med 2012; 156: 115–122.
    OpenUrlCrossRefPubMedWeb of Science
  6. ↵
    1. Martínez-García MA,
    2. Campos-Rodríguez F,
    3. Catalán-Serra P,
    4. et al
    . Cardiovascular mortality in obstructive sleep apnea in the elderly: role of long-term continuous positive airway pressure treatment: a prospective observational study. Am J Respir Crit Care Med 2012; 186: 909–916.
    OpenUrlCrossRefPubMedWeb of Science
  7. ↵
    1. Barbé F,
    2. Durán-Cantolla J,
    3. Sánchez-de-la-Torre M,
    4. et al
    . Effect of continuous positive airway pressure on the incidence of hypertension and cardiovascular events in nonsleepy patients with obstructive sleep apnea: a randomized controlled trial. JAMA 2012; 307: 2161–2168.
    OpenUrlCrossRefPubMedWeb of Science
  8. ↵
    1. Weaver TE,
    2. Maislin G,
    3. Dinges DF,
    4. et al
    . Relationship between hours of CPAP use and achieving normal levels of sleepiness and daily functioning. Sleep 2007; 30: 711–719.
    OpenUrlPubMedWeb of Science
    1. Antic NA,
    2. Catcheside P,
    3. Buchan C,
    4. et al
    . The effect of CPAP in normalizing daytime sleepiness, quality of life, and neurocognitive function in patients with moderate to severe OSA. Sleep 2011; 34: 111–119.
    OpenUrlPubMedWeb of Science
    1. Stradling JR,
    2. Davies RJ
    . Is more NCPAP better? Sleep 2000; 23 Suppl. 4:S150–S153.
    OpenUrlPubMedWeb of Science
  9. ↵
    1. Zimmerman ME,
    2. Arnedt JT,
    3. Stanchina M,
    4. et al
    . Normalization of memory performance and positive airway pressure adherence in memory-impaired patients with obstructive sleep apnea. Chest 2006; 130: 1772–1778.
    OpenUrlCrossRefPubMedWeb of Science
  10. ↵
    1. Lettieri CJ,
    2. Walter RJ
    . Impact of group education on continuous positive airway pressure adherence. J Clin Sleep Med 2013; 9: 537–541.
    OpenUrlPubMed
    1. Meurice JC,
    2. Ingrand P,
    3. Portier F,
    4. et al
    . A multicentre trial of education strategies at CPAP induction in the treatment of severe sleep apnoea-hypopnoea syndrome. Sleep Med 2007; 8: 37–42.
    OpenUrlCrossRefPubMedWeb of Science
    1. Falcone VA,
    2. Damiani MF,
    3. Quaranta VN,
    4. et al
    . Polysomnograph chart view by patients: a new educational strategy to improve CPAP adherence in sleep apnea therapy. Respir Care 2014; 59: 193–198.
    OpenUrlAbstract/FREE Full Text
    1. Damjanovic D,
    2. Fluck A,
    3. Bremer H,
    4. et al
    . Compliance in sleep apnoea therapy: influence of home care support and pressure mode. Eur Respir J 2009; 33: 804–811.
    OpenUrlAbstract/FREE Full Text
    1. Lai AY,
    2. Fong DY,
    3. Lam JC,
    4. et al
    . The efficacy of a brief motivational enhancement education program on CPAP adherence in OSA: a randomized controlled trial. Chest 2014; 146: 600–610.
    OpenUrlCrossRefPubMedWeb of Science
  11. ↵
    1. Olsen S,
    2. Smith SS,
    3. Oei TP,
    4. et al
    . Motivational interviewing (MINT) improves continuous positive airway pressure (CPAP) acceptance and adherence: a randomized controlled trial. J Consult Clin Psychol 2012; 80: 151–163.
    OpenUrlCrossRefPubMed
  12. ↵
    1. Bouloukaki I,
    2. Giannadaki K,
    3. Mermigkis C,
    4. et al
    . Intensive versus standard follow-up to improve continuous positive airway pressure compliance. Eur Respir J 2014; 44: 1262–1274.
    OpenUrlAbstract/FREE Full Text
View Abstract
PreviousNext
Back to top
View this article with LENS
Vol 44 Issue 5 Table of Contents
European Respiratory Journal: 44 (5)
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Should use of 4 hours continuous positive airway pressure per night be considered acceptable compliance?
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Should use of 4 hours continuous positive airway pressure per night be considered acceptable compliance?
Juan F. Masa, Jaime Corral-Peñafiel
European Respiratory Journal Nov 2014, 44 (5) 1119-1120; DOI: 10.1183/09031936.00121514

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Should use of 4 hours continuous positive airway pressure per night be considered acceptable compliance?
Juan F. Masa, Jaime Corral-Peñafiel
European Respiratory Journal Nov 2014, 44 (5) 1119-1120; DOI: 10.1183/09031936.00121514
Reddit logo Technorati logo Twitter logo Connotea logo Facebook logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Footnotes
    • References
  • Info & Metrics
  • PDF

Subjects

  • Sleep medicine
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • ERS Tobacco Control Committee statement on Tobacco 21
  • Inflammatory biomarkers in PAH and clinical implementation?
  • NSAIDs, respiratory disease, dupilumab and aspirin tolerance
Show more Editorials

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society