Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions

Continuous positive airway pressure delivered by oronasal mask may not be effective for obstructive sleep apnoea

Fabíola Schorr, Pedro R. Genta, Marcelo G. Gregório, Naury J. Danzi-Soares, Geraldo Lorenzi-Filho
European Respiratory Journal 2012 40: 503-505; DOI: 10.1183/09031936.00145111
Fabíola Schorr
Sleep Laboratory, Pulmonary Division, Heart Institute (InCor), University of São Paulo School Medicine, São Paulo, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pedro R. Genta
Sleep Laboratory, Pulmonary Division, Heart Institute (InCor), University of São Paulo School Medicine, São Paulo, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marcelo G. Gregório
Sleep Laboratory, Pulmonary Division, Heart Institute (InCor), University of São Paulo School Medicine, São Paulo, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Naury J. Danzi-Soares
Sleep Laboratory, Pulmonary Division, Heart Institute (InCor), University of São Paulo School Medicine, São Paulo, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Geraldo Lorenzi-Filho
Sleep Laboratory, Pulmonary Division, Heart Institute (InCor), University of São Paulo School Medicine, São Paulo, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

To the Editors:

Continuous positive airway pressure (CPAP) is considered the gold standard treatment for patients with moderate to severe obstructive sleep apnoea (OSA). The treatment of OSA with CPAP was first conceptualised using a nasal-only interface because the pressure delivered through the nose would be transmitted to the back of the upper airway and would push the palate anteriorly [1]. Since the first description, the CPAP industry has developed a large number of different interfaces in order to improve patient comfort and adherence to treatment. Patients with OSA frequently present nasal obstruction and oronasal interfaces may be used to deliver CPAP. Nasal and oronasal masks are often used interchangeably and the choice of CPAP delivery interface for OSA therapy remains largely based on clinical experience. However, patients with OSA on oronasal mask are less adherent to CPAP for reasons that are not completely understood [2]. One recent randomised trial [3] and a preliminary report [4] suggest that the effectiveness of CPAP for treating OSA is variable when delivered by an oronasal interface. We describe a well-documented patient in whom CPAP was not effective when an oronasal mask was used due to the posterior displacement of the tongue.

A 69-yr-old Japanese–Brazilian, body mass index 26.1 kg·m−2, presented to the outpatient sleep clinic complaining of typical symptoms suggestive of OSA, including loud snoring, witnessed apnoeas and excessive daytime sleepiness. The patient had a positive medical history of systemic hypertension and diabetes mellitus. A standard overnight polysomnography (Alice 5; Philips Respironics, Murrysville, PA, USA) confirmed severe OSA, with apnoea-hypopnoea index (AHI) 76 events per h and lowest oxygen saturation 58%. An in-laboratory manual CPAP titration study was performed with an oronasal mask because of reported oral breathing during sleep. CPAP was gradually increased up to 16 cmH2O with no clear elimination of OSA at any single CPAP. The overall AHI during the CPAP titration with oronasal mask was 32 events per h and the lowest oxygen saturation was 78%. The patient was then scheduled for a new CPAP titration study that was initiated with a nasal mask, with elimination of OSA at CPAP of 7 cmH2O. The mask was changed to an oronasal mask during the second half of the study. In contrast to the first half and similar to the first titration study, OSA was not abolished and obstructive hypopnoeas persisted despite a progressive raise of CPAP up to 16 cmH2O (fig. 1). We therefore hypothesised that CPAP delivered by an oronasal interface was not effective due to posterior displacement of the tongue caused by oral pressure. The patient was submitted to a sleep endoscopy study in the early morning using an intravenous infusion of midazolam that was slowly titrated until initiation of sleep, as previous described [5]. The endoscope was inserted through a latex-sealed hole in the mask to directly visualise the upper airway. The oropharyngeal region was observed while the patient used both nasal and oronasal mask. The oropharynx was open while the patient was on nasal mask at CPAP of 7 cmH2O but was partially obstructed while on oronasal mask at CPAP of 16 cmH2O due to a posterior displacement of the tongue. The images were reviewed off line, frame by frame, and pictures were taken at the smallest upper airway dimension during each condition, corresponding to early inspiration (fig. 1). Air leak with oronasal mask at CPAP of 16 cmH2O was 57 and 30 L·min−1 during the CPAP titration night and induced sleep, respectively. During the latter condition pressure at the mask and was equal to the set by the equipment. A nasal CPAP of 7 cmH2O was prescribed and the patient reported significant improvement of symptoms after 3 months of follow-up.

Figure 1–
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1–

Polysomnography summary of a natural sleep continuous positive airway pressure (CPAP) titration study (top) and sleep endoscopy images (bottom) using both nasal and oronasal masks. During the first part of the natural sleep CPAP titration, a nasal CPAP of 7 cmH2O adequately controlled obstructive events. During the second part, an oronasal mask was used. Observe the persistence of obstructive respiratory events even at pressures up to 16 cmH2O. The endoscopic image taken with nasal CPAP of 7 cmH2O shows a wide open oropharynx. In contrast, the image taken with oronasal CPAP of 16 cmH2O shows the tongue base posteriorly displaced, pushing the epiglottis and significantly narrowing the airway. Sp,O2: arterial oxygen saturation measured by pulse oximetry; CA: central apnoea; OA: obstructive apnoea; MA: mixed apnoea; HYPO: hypopnoea; PAP: pulmonary artery pressure; REM: rapid eye movement. Respiratory event time is shown in seconds.

The present case report conveys two important messages that may be relevant to some patients regarding the choice of CPAP interfaces for the treatment of OSA. First, in contrast to nasal interface, CPAP delivered by an oronasal interface was not completely effective in treating OSA. In our patient, a relatively low nasal CPAP (7 cmH2O) was able to abolish OSA. In contrast, three independent sleep studies (including two natural sleep studies and one induced sleep study with midazolam) showed that CPAP titrated up to 16 cmH2O using an oronasal interface did not adequately treat OSA. Secondly, the direct visualisation of the upper airway during CPAP titration provided a mechanism to explain this apparent paradox. We showed that, as expected, the upper airway was open at nasal CPAP of 7 cmH2O. In contrast, the oropharyngeal airway was partially obstructed while on oronasal CPAP of 16 cmH2O mask due to a posterior displacement of the tongue. The study therefore suggests that the pressure delivered through the mouth may push the tongue backwards. This hypothesis is consistent with a previous report showing that CPAP through an oronasal mask was not able to open the upper airway even at pressures well above the calculated critical closing pressure obtained with a nasal mask [6]. A significant air leak on oronasal mask could lead to insufficient mask pressure and explain the lack of treatment effect. However, the pressure delivered at the mask during induced sleep was equal to that displayed by the equipment. Because obstruction occurred immediately after the interface was changed, it is unlikely that obstruction was caused by an increase in surface tension due to dryness of the upper airways associated with oral breathing. One alternative explanation is that the oronasal mask pushed the mandible backwards, causing a false retrognathism. Although we did not use any imaging method to detect changes in mandibular position in our patient, one recent preliminary study that compared nasal and oronasal interface with and without a mandibular advancement device (MAD) in a group of OSA patients with a history of difficult CPAP titration showed no impact of MAD on the titrated oronasal CPAP in most cases. Interestingly enough, in this preliminary study, four out of eight patients had obstructive events even after a CPAP of 20 cmH2O was reached while using an oronasal mask [4]. One limitation of our case report is that we were not able to quantify the proportion of nasal and oral breathing while the oronasal mask was used. It is possible that this is a major determinant of how the oronasal interface will impact on the distribution of pressures in the nasal and oral segments. There is evidence that upper airway resistance during sleep and the propensity to obstructive sleep apnoea are significantly lower while breathing nasally rather than orally [7].

Teo et al. [3] have recently reported the first randomised trial that compared CPAP titration with nasal and oronasal masks in patients with newly diagnosed OSA. While the CPAP pressures achieved by nasal and oronasal interfaces was similar (∼11 cmH2O) the AHI was significantly lower on nasal mask (5.3±3.4 versus 11.0±10.4 events per h, respectively; p=0.01). Moreover, the high AHI standard deviation while on oronasal mask indicates a wide effectiveness variability. In the study of Teo et al. [3] the use of oronasal mask was also associated with worse sleep quality, higher air leak and poorer patient satisfaction. We speculate that the observed mechanisms in our patient may help to explain why several patients are not effectively treated while on oronasal CPAP. These mechanisms may contribute to higher air leak and poorer treatment satisfaction.

In conclusion, our case report is in line with recent studies suggesting that CPAP delivered by oronasal interface may not be effective in a subgroup of patients with OSA [3, 4]. Our case report suggests that CPAP delivered through an oronasal interface may push the tongue backwards in some patients. Therefore, a nasal mask should be preferred as the first option as a CPAP interface. Patients on an oronasal mask should be carefully followed. The low compliance to CPAP when an oronasal interface is used may be partially explained by suboptimal therapeutic effectiveness.

  • ©ERS 2012

REFERENCES

  1. ↵
    1. Sullivan CE,
    2. Issa FG,
    3. Berthon-Jones M,
    4. et al
    . Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares. Lancet 1981; 1: 862–865.
    OpenUrlPubMedWeb of Science
  2. ↵
    1. Mortimore IL,
    2. Whittle AT,
    3. Douglas NJ
    . Comparison of nose and face mask CPAP therapy for sleep apnoea. Thorax 1998; 53: 290–292.
    OpenUrlAbstract/FREE Full Text
  3. ↵
    1. Teo M,
    2. Amis T,
    3. Lee S,
    4. et al
    . Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome. Sleep 2011; 34: 951–955.
    OpenUrlPubMedWeb of Science
  4. ↵
    1. Kaminska M,
    2. Montpetit A,
    3. Mathieu A,
    4. et al
    . Differences in effectiveness of nasal and facial CPAP masks in obstructive sleep apnea, and effect of mandibular stabilization. Sleep 2010; 33: Suppl, A158.
    OpenUrl
  5. ↵
    1. Gregório MG,
    2. Jacomelli M,
    3. Inoue D,
    4. et al
    . Comparison of full versus short induced-sleep polysomnography for the diagnosis of sleep apnea. Laryngoscope 2011; 121: 1098–1103.
    OpenUrlCrossRefPubMedWeb of Science
  6. ↵
    1. Smith PL,
    2. Wise RA,
    3. Gold AR,
    4. et al
    . Upper airway pressure–flow relationships in obstructive sleep apnea. J Appl Physiol 1988; 64: 789–795.
    OpenUrlAbstract/FREE Full Text
  7. ↵
    1. Fitzpatrick MF,
    2. McLean H,
    3. Urton AM,
    4. et al
    . Effect of nasal or oral breathing route on upper airway resistance during sleep. Eur Respir J 2003; 22: 827–832.
    OpenUrlAbstract/FREE Full Text
View Abstract
PreviousNext
Back to top
View this article with LENS
Vol 40 Issue 2 Table of Contents
European Respiratory Journal: 40 (2)
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Continuous positive airway pressure delivered by oronasal mask may not be effective for obstructive sleep apnoea
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Continuous positive airway pressure delivered by oronasal mask may not be effective for obstructive sleep apnoea
Fabíola Schorr, Pedro R. Genta, Marcelo G. Gregório, Naury J. Danzi-Soares, Geraldo Lorenzi-Filho
European Respiratory Journal Aug 2012, 40 (2) 503-505; DOI: 10.1183/09031936.00145111

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Continuous positive airway pressure delivered by oronasal mask may not be effective for obstructive sleep apnoea
Fabíola Schorr, Pedro R. Genta, Marcelo G. Gregório, Naury J. Danzi-Soares, Geraldo Lorenzi-Filho
European Respiratory Journal Aug 2012, 40 (2) 503-505; DOI: 10.1183/09031936.00145111
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Subjects

  • Sleep medicine
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Burden of CAP in Italian general practice
  • Neutrophilia independently predicts death in tuberculosis
  • Fibrosis in dyskeratosis congenita with TINF2 mutation
Show more Letters

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2022 by the European Respiratory Society