Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions

Stitching and switching: the impact of discontinuous lung function reference equations

Jane Kirkby, Paul Aurora, Helen Spencer, Stephanie Rees, Samantha Sonnappa, Janet Stocks
European Respiratory Journal 2012 39: 1256-1257; DOI: 10.1183/09031936.00173011
Jane Kirkby
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: j.kirkby@ich.ucl.ac.uk
Paul Aurora
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Helen Spencer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephanie Rees
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Samantha Sonnappa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Janet Stocks
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

To the Editors:

In order to distinguish the effects of lung disease from those of normal growth and development, lung function is expressed in comparison with reference data, with forced expiratory volume in 1 s (FEV1) commonly being presented as % predicted. FEV1 % pred has been identified as being of prognostic value in cystic fibrosis (CF), such that an FEV1 of <30% pred or rapid decline to that level should prompt referral to a transplant centre [1]. Subsequent monitoring of FEV1 % pred after lung transplantation is also important for monitoring graft function and is required to detect any signs of rejection or onset of bronchiolitis obliterans syndrome (BOS), a disease defined as a fall in FEV1 of >20% from baseline determined by the average of two measurements made ≥3 weeks apart. Continuing to monitor FEV1 % pred after the development of BOS has also been shown to provide important insight into the patient’s prognosis and therapeutic options [2].

Given that FEV1 % pred plays such a key role in the clinical management of a child with CF or any child who has undergone lung transplantation, it is imperative to ensure that it is measured and interpreted accurately. Although guidelines for standardised measurement of spirometry have been developed for both adults [3] and children [4], the decision on which spirometry reference equation to use, amongst the plethora available [5], varies widely. This situation is further complicated by the fact that until recently published equations, and, hence, those incorporated into commercial spirometry devices, only incorporated certain age ranges, thereby necessitating a combination of different equations when undertaking serial measurements commencing in childhood.

In the UK, the British Thoracic Society currently recommends the equations of Rosenthal et al. [6] for children aged 4–18 yrs, and the European Coal and Steel Community (ECSC) equations for adults [7], whereas various different combinations are recommended by other international respiratory societies. These recommendations mean that as a child turns 18 yrs of age and moves into adult care, a change in reference equations is required. The extent to which this may introduce bias in predicted values and, hence, in clinical interpretation of results is not generally appreciated, especially as many manufacturers “stitch” equations representing different age groups together so that the user is presented with apparently seamless predictions, with no overt warning at periods of transition.

The magnitude of such potential errors can be illustrated by an 18-yr-old male with CF who had been undergoing regular serial spirometry measurements after lung transplantation. His progress post-transplant in 2007 (aged 14 yrs) had been generally good, with only one instance of severe respiratory compromise (January 2011, aged 17 yrs). On that occasion, his FEV1 fell to 1.44 L (57% pred), from the usual baseline of ∼2.0 L (∼80% pred according to Rosenthal et al. [6]). After appropriate prompt investigation and treatment, his FEV1 returned to 2.09 L (82% pred). On his next visit to the lung function laboratory in April 2011, aged 18 yrs, he recorded a FEV1 of 58% pred, which would be deemed consistent with a significant illness (similar to that seen 3 months previously). However, during clinical review, it was noted that the patient had no other symptoms of respiratory compromise and claimed to be well. It was also noted that, although the patient’s FEV1 % pred had decreased dramatically (fig. 1a), his absolute FEV1 was 2.13 L, which was consistent with his stable baseline (fig. 1b). The apparent decline in lung function was, therefore, not a reflection of any clinical change, but simply an automated, internal switching between paediatric and adult reference equations by the spirometry software. The magnitude of error when calculating the apparent change in predicted FEV1 was such that, had the underlying cause not been rapidly identified, an urgent admission and invasive evaluation would have been triggered.

Figure 1–
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1–

Serial measurements of forced expiratory volume in 1 s (FEV1) in a young male with cystic fibrosis lung disease. a) FEV1 % predicted (% pred) as reported by the equipment (Rosenthal et al. [6] paediatric equation for ages 6–17.9 yrs and adult equations of the European Coal and Steel Community [7] for >18 yrs of age). b) Absolute values of FEV1. c) FEV1 % pred using the all-age reference equations of Stanojevic et al. [8]. The data points represent serial FEV1 measurements prior to and following lung transplantation. The first vertical dashed line (time 1) indicates time of lung transplantation at 14 yrs of age, after which there was marked improvement in lung function, which was consistently maintained until the second dotted line (time 2; 17 yrs 9 months of age), where there was a drop in lung function associated with an acute respiratory infection that was successfully treated. The third dotted line (time 3) indicates the patient’s 18th birthday and the switch between paediatric and adult equations, resulting in an apparent dramatic reduction of lung function on the last test occasion, which was not accompanied by any change in clinical status. Inspection of absolute values (b) confirmed that level of lung function had in fact been maintained over the last two test occasions. Use of the all-age equations (c), which provide a smooth transition from early childhood to old age, allowed accurate interpretation of the results.

The magnitude of observed differences when switching between paediatric and adult reference ranges are most dramatic when using paediatric equations that do not include age (such as those of Rosenthal et al. [6]) in height-restricted subjects. Since many children with lung disease have some degree of growth restriction [9], the potential underestimation of predicted (and, hence, overestimation of % pred) values means that the incident reported here could frequently occur in other patients. Furthermore, it is increasingly recognised that the use of the ECSC equations in adults is not without its problems [10].

With the recent introduction of all-age reference equations [8], such scenarios could easily be avoided. These equations provide smoothly changing curves to describe the transition between childhood and adulthood, and eliminate the arbitrary break points which occur when using different equations over different ranges of age or height (fig. 1c). These equations represent the largest collation of healthy spirometry data published to date, but are currently limited to the Caucasian population and, despite recent incorporation into some commercially available spirometers (see www.lungfunction.org for details), are still not widely available for use in clinical laboratories. Recent work by the American Thoracic Society/Asian Pacific Society of Respirology/European Respiratory Society Task Force to Establish Improved Lung Function Reference Values to extend the all-age spirometry reference equations to an even wider age range (3–90 yrs) and other ethnic groups offers the means to overcome problems relating to switching between equations in the near future. However, for these to have any practical impact in clinical laboratories, rapid incorporation into commercial equipment and endorsement by the relevant professional bodies internationally will be essential.

The responsibility to “treat the patient and not the numbers” should always remain with the clinical staff. Nevertheless, given the potentially serious clinical implications of “stitching and switching” reference equations, there is an urgent need to change international recommendations regarding such practices and to ensure that appropriate equations, to avoid such errors, are readily implemented in commercially available equipment to facilitate their widespread use in both clinical practice and research applications.

Footnotes

  • Statement of Interest

    None declared.

  • ©ERS 2012

REFERENCES

  1. ↵
    1. Aurora P,
    2. Carby M,
    3. Sweet S
    . Selection of cystic fibrosis patients for lung transplantation. Curr Opin Pulm Med 2008; 14: 589–594.
    OpenUrlCrossRefPubMed
  2. ↵
    1. Lama VN,
    2. Murray S,
    3. Lonigro RJ,
    4. et al
    . Course of FEV1 after onset of bronchiolitis obliterans syndrome in lung transplant recipients. Am J Respir Crit Care Med 2007; 175: 1192–1198.
    OpenUrlCrossRefPubMedWeb of Science
  3. ↵
    1. Miller MR,
    2. Hankinson J,
    3. Brusasco V,
    4. et al
    . Standardisation of spirometry. Eur Respir J 2005; 26: 319–338.
    OpenUrlAbstract/FREE Full Text
  4. ↵
    1. Beydon N,
    2. Davis SD,
    3. Lombardi E,
    4. et al
    . An official American Thoracic Society/European Respiratory Society statement: pulmonary function testing in preschool children. Am J Respir Crit Care Med 2007; 175: 1304–1345.
    OpenUrlCrossRefPubMedWeb of Science
  5. ↵
    1. Stanojevic S,
    2. Wade A,
    3. Stocks J
    . Reference values for lung function: past, present and future. Eur Respir J 2010; 36: 12–19.
    OpenUrlAbstract/FREE Full Text
  6. ↵
    1. Rosenthal M,
    2. Bain SH,
    3. Cramer D,
    4. et al
    . Lung function in white children aged 4 to 19 years: I – Spirometry. Thorax 1993; 48: 794–802.
    OpenUrlAbstract/FREE Full Text
  7. ↵
    1. Quanjer PH,
    2. Tammeling GJ,
    3. Cotes JE,
    4. et al
    . Volumes pulmonaires et débits ventilatoires forcés. Groupe de travail sur la standardisation des épreuves fonctionnelles respiratoires. Communauté Européenne du Charbon et de l'Acier. Position officielle de l'European Respiratory Society [Lung volumes and forced ventilatory flows. Work Group on Standardization of Respiratory Function Tests. European Community for Coal and Steel. Official position of the European Respiratory Society]. Rev Mal Respir 1994; 11: Suppl. 3, 5–40.
    OpenUrlPubMedWeb of Science
  8. ↵
    1. Stanojevic S,
    2. Wade A,
    3. Cole TJ,
    4. et al
    . Spirometry centile charts for young Caucasian children: the Asthma UK Collaborative Initiative. Am J Respir Crit Care Med 2009; 180: 547–552.
    OpenUrlCrossRefPubMedWeb of Science
  9. ↵
    1. Davis PB,
    2. Kercsmar CM
    . Growth in children with chronic lung disease. N Engl J Med 2000; 342: 887–888.
    OpenUrlCrossRefPubMedWeb of Science
  10. ↵
    1. Quanjer PH,
    2. Erasmus M,
    3. Stanojevic S
    . Internal consistency of reference equations. Eur Respir J 2011; 38: 234–235.
    OpenUrlFREE Full Text
View Abstract
PreviousNext
Back to top
View this article with LENS
Vol 39 Issue 5 Table of Contents
European Respiratory Journal: 39 (5)
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Stitching and switching: the impact of discontinuous lung function reference equations
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Stitching and switching: the impact of discontinuous lung function reference equations
Jane Kirkby, Paul Aurora, Helen Spencer, Stephanie Rees, Samantha Sonnappa, Janet Stocks
European Respiratory Journal May 2012, 39 (5) 1256-1257; DOI: 10.1183/09031936.00173011

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Stitching and switching: the impact of discontinuous lung function reference equations
Jane Kirkby, Paul Aurora, Helen Spencer, Stephanie Rees, Samantha Sonnappa, Janet Stocks
European Respiratory Journal May 2012, 39 (5) 1256-1257; DOI: 10.1183/09031936.00173011
Reddit logo Technorati logo Twitter logo Connotea logo Facebook logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Subjects

  • Lung structure and function
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Obesity in COPD: the effect of water-based exercise
  • Burden of CAP in Italian general practice
  • Neutrophilia independently predicts death in tuberculosis
Show more Letters

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society