Abstract
Although noninvasive ventilation (NIV) is becoming very popular, little is known about its pattern of clinical and technical utilisation in different environments.
We conducted a web-based survey in Europe to identify the perceived pattern of NIV utilisation and the reason for choosing a specific ventilator and interface type in four common clinical scenarios: acute hypercapnic respiratory failure (AHRF), cardiogenic pulmonary oedema (CPE), de novo hypoxic respiratory failure and weaning/post-extubation failure (W/PE).
A response was obtained from 272 (51.3%) out of 530 selected European physicians involved in NIV practice. The NIV utilisation rate was higher for pulmonologists than intensivists/anesthesiologists (p<0.05). The most common indication for all the physicians was AHRF (48%). Physicians were more likely to use NIV dedicated ventilator in AHRF and CPE and an intensive care unit (ICU) ventilator with NIV module in de novo hypoxic respiratory failure and W/PE, mainly because of the possibility of using the double circuit and inspiratory oxygen fraction control. Overall, the oro-nasal mask was the most frequently used interface, irrespective of clinical scenarios.
The use of NIV in Europe is generally relatively high, especially among pulmonologists and in AHRF. Dedicated NIV ventilators and ICU ventilators with NIV modules are preferably in AHRF and in de novo hypoxic respiratory failure, respectively, together with oro-nasal masks.
Noninvasive ventilation (NIV) is well recognised as a valid strategy to avoid endotracheal intubation and its complications in selected patients with respiratory failure 1, 2.
Some surveys have shown that the utilisation of NIV may greatly vary depending on the geographical location and the types of environment. Between 1997 and 2002, NIV use in French intensive care units (ICUs) increased from 16% to 24% of the total ventilated patients and from 35% to 52% of the patients starting ventilation in the ICU 3, while in other European countries and North America the utilisation rate is much lower 4, 5.
In certain areas, this low rate is related to lack of knowledge or experience concerning the technique, insufficient technical equipment such as specific ventilators and ad hoc interfaces, and lack of funding 4. Despite these difficulties, NIV use has also increased outside the ICU setting, including high-dependency units, respiratory wards, emergency rooms and post-surgical recovery rooms 6–8.
Nowadays, considerable technological advances have been made by manufactures both in the development of new ventilatory modes and more sophisticated machines and interfaces, enabling physicians to choose the appropriate device for each patient.
We used an ad hoc designed web questionnaire to assess current NIV practices in various environments in Europe and in different case scenarios, placing emphasis on the technical aspects of NIV use.
METHODS
We conducted a web survey of physicians dealing with NIV in 25 European countries between January and March 2008.
The survey was sent to all members of the Respiratory Intensive Care Assembly from the European Respiratory Society (ERS), members of the Acute Respiratory Failure Group from the European Society of Intensive Care Medicine (ESICM), and physicians working in the emergency department (ED) known to be involved in NIV practice or to have published articles on the topic. Only a few members (n = 12) of the non-European countries (mainly from the Middle East) were also included in the survey as they were members of either the ERS or the ESICM.
A survey instrument 9 was developed to examine physicians' knowledge, attitudes and practice about NIV use in four common clinical scenarios.
We performed individual semi-structured interviews with a group of local pulmonologists and intensivists to identify content areas and items of interest, in order to generate items and formulate questions.
Pilot testing was also performed to test content validity, reliability and relevance of the questionnaire and the ability to discriminate among respondents. Pre-testing and pilot testing were used to improve the questionnaire wording. The questionnaire showed good internal consistency and reliability with Cronbach's α ≥0.78. Clinical sensibility testing was conducted through personal interviews with four intensivists and four pulmonologists from Europe in order to evaluate the comprehensiveness, clarity and validity. The questionnaire had adequate content validity showing a content validity index of ≥0.78.
We developed survey questions with a structured response format using multiple choice responses and Likert scales, and following this created a user-friendly web-based questionnaire.
Questions were presented on a series of linked pages (multiple-item screens) with progress indicators. Radio buttons and list box were used to encourage users to choose only one option from a predefined set of alternatives. Questions were ordered on the basis of content: broad questions on respondents' demographics and professional data; specific questions addressing physicians' experience and confidence with NIV; and scenario-based questions asking physicians about their own clinical experience with NIV in four common case scenarios: 1) acute hypercapnic respiratory failure (AHRF); 2) cardiogenic pulmonary oedema (CPE); 3) acute lung injury/acute respiratory distress syndrome/community-acquired pneumonia/post surgical (de novo respiratory failure); 4) weaning/post-extubation failure (W/PE).
Respondents were linked to a specific scenario-based section in which they were asked to select the type of ventilator and interface they preferably choose when using NIV. We identified some variables considered to be potentially important in their choice of a specific ventilator or interface type for each clinical scenario, and asked respondents to rate their importance in the decision making process using a five-point Likert scale ranging from 1 (irrelevant) to 5 (very important).
Each physician was provided with a personal username and password giving them access to a secure internet-based questionnaire. The final surveys were e-mailed to a total of 530 physicians. Reminders were sent to clinicians who did not respond to the first e-mail within 8 weeks.
Statistical analysis
The countries were divided into three geographical areas prior to data analysis: Northern Europe; Central Europe; and Southern Europe and the Middle-East (table 1).
Descriptive statistics (means, medians and proportions) were used to report responses to survey items and to summarise respondents' characteristics. The Kruskal–Wallis test for nonparametric data was used to evaluate the variability in NIV utilisation among different clinical scenarios and physician groups (intensivists versus pulmonologists versus others). Cochran's Q-test was used to test for the variability in the attitudes toward the use of different ventilator and mask types for each scenario.
Multivariate analysis
We conducted multivariate analysis using the “supervised learning” technique that allowed us to generate models, assuming a priori the presence of categories.
The data on ventilators were processed, generating the following model: ventilator types as category index (ICU ventilator with NIV module, ICU ventilator without NIV module, dedicated ventilator for acute NIV, home-care ventilator for chronic NIV, stand-alone continuous positive airway pressure (CPAP) generator) and the reasons for ventilator choice, plus the geographical area, physician types and clinical scenarios as variables.
In a similar way, mask data were processed, generating the following model: mask types as category index (nasal, oro-nasal, total face, helmet, others) and the reasons for interface choice, plus the geographical area, physician types and clinical scenarios as variables.
Each model was processed using stepwise linear discriminant analysis (STEPLDA) to determine the variables that enhance discrimination among the respective categories. New dataset created on every STEPLDA run contained the original category index and objects but only the most discriminant variables. The K-nearest neighbor (kNN) algorithm was applied for each new dataset to estimate the accuracy of the models and discrimination capability.
Statistical analysis was performed using SPSS version 15 (SPSS Inc., Chicago, IL, USA) and PARVUS 2008 10. A probability value of p<0.05 was considered to be statistically significant.
RESULTS
272 (51.3%) of 530 physicians (133 pulmonologists, 109 intensivists/anesthesiologists and 30 others) responded to the survey. Respondents' characteristics are shown in table 2. Scenario, ventilator and mask distribution in countries with the highest number of respondents are shown in table 3.
Rate of NIV utilisation
The NIV utilisation rate was significantly higher for pulmonologists (52.9% reported >20% of patients treated with NIV per year) versus intensivists/anesthesiologists (34.3%) versus others (12.6%) (p<0.05). Among the scenarios, physicians rated AHRF as the most common indication for the use of NIV (48.06%).
Overall, attitudes toward the use of NIV in clinical settings differed significantly among the groups of physician respondents (fig. 1). Pulmonologists were more likely to use NIV in the treatment of AHRF compared to intensivists (58.9% versus 35.2%). Conversely the latter were more likely to use NIV in patients with CPE (18.7% versus 7.2%), de novo respiratory failure (19.1% versus 6.2%) and W/PE (14.4% versus 8.5%), (p<0.05).
Differences in noninvasive ventilation attitudes among physicians. □: acute hypercapnic respiratory failure; ░: cardiogenic pulmonary oedema; ▪: de novo acute respiratory failure; : weaning/post-extubation failure. *: p<0.05 between intensivists/anesthesiologists and pulmonologists.
Ventilator choice
Figure 2 shows ventilator distribution among the four clinical scenarios and for each type of physician.
Ventilator distribution for a) each clinical case scenario and b) each type of physician. NIV: noninvasive ventilation; ICU: intensive care unit; CPAP; continuous positive airway pressure. □: acute hypercapnic respiratory failure; ░; cardiogenic pulmonary oedema; ▪: de novo acute respiratory failure; ▓: weaning/post-extubation failure; : intensivists;
: pulmonologists; ▒: others.
In AHRF patients, physicians were more likely to use NIV dedicated ventilator, compared to an ICU ventilator with NIV module or other types of ventilators (p<0.01).
In CPE, NIV dedicated ventilators and ICU ventilators with NIV module were mostly used, with stand-alone CPAP generator employed by ∼23% of the respondents (nonsignificant).
In de novo respiratory failure and W/PE scenarios we found similar distribution rates: an ICU ventilator with NIV module was significantly more widely used than NIV dedicated ventilator (p = 0.02 and p = 0.01 for de novo respiratory failure and W/PE, respectively). Considering the distribution of ventilators based on physician qualification and regardless of the scenario, the most frequent ventilator type used during NIV by the intensivists/anesthesiologists was the ICU ventilator with NIV module, conversely NIV dedicated ventilator was the preferred choice of pulmonologists (fig. 2b).
The reasons for choosing a specific ventilator, as assessed using the discriminant analysis, are shown in figure 3a. In decreasing order of power, the significant parameters which provided distinction among the ventilator types were: double circuit; inspiratory oxygen fraction (Fi,O2) control; ease of transport; monitoring capability; drug delivery; and possibility of setting alarms. The ability of each parameter in discriminating among ventilators was investigated using a kNN classifier. The previously mentioned parameters, together with physician types (F = 36.3), had a kNN of 76.4% for ICU ventilator with NIV module and 65.8% for NIV dedicated ventilator (fig. 3b).
a) The factors identified as determinants in the decision to choose a specific ventilator type by multivariate analysis using stepwise linear discriminant analysis. The F to enter value indicates Likert scale variables statistical significance in the discrimination among ventilator types. F to enter is a measure of the extent to which a variable makes a unique contribution to the prediction of group membership. b) The factors identified by the multivariate analysis cross-validated by the k-nearest neighbor algorithm (kNN), which tests the accuracy (or percentage of correctly classified cases) of the parameters in discriminating among ventilators. Fi,O2: inspiratory oxygen fraction; ICU: intensive care unit; NIV: noninvasive ventilation; CPAP: continuous positive airway pressure.
Interface choice
Interface preferences were not influenced by clinical scenarios and the oro-nasal mask was the most frequently used overall (p<0.01) (fig. 4a), irrespective of the type of physician (fig. 4b).
Interface distribution for a) each clinical-case scenario and b) each type of physician. □: acute hypercapnic respiratory failure; ░; cardiogenic pulmonary oedema; ▪: de novo acute respiratory failure; ▓: weaning/post-extubation failure; : intensivists;
: pulmonologists; ▒: others.
Geographical area (i.e. greater use of the helmet and total face mask in Southern Europe), patient comfort, multiple patient use, leaks and costs were factors significantly associated with mask choice (fig. 5a). The ability of each parameter in discriminating among interfaces, investigated using a kNN classifier, showed that the previously mentioned parameters, together with the physician type (F = 4.5), had a kNN of 88.9% for the oro-nasal mask (fig. 5b).
a) Factors identified as determinants in the decision to choose a specific ventilator type by multivariate analysis, using the stepwise linear discriminant analysis. The F to enter value indicates variable statistical significance in the discrimination between mask types. F to enter is a measure of the extent to which a variable makes a unique contribution to the prediction of group membership. b) Factors identified by the multivariate analysis cross-validated by the k-nearest neighbor algorithm (kNN), which tests the accuracy (or percentage of correctly classified cases) of the parameters in discriminating among interfaces.
Humidification
As shown in figure 6, the humidification use, as assessed by a dichotomic response (yes/no), was >50% in all the clinical scenarios except for CPE.
Humidification use (yes: □ no: ▓) among the different clinical scenarios. AHRF: acute hypercapnic respiratory failure; CPE: cardiogenic pulmonary oedema; ARF: acute respiratory failure; W/PE: weaning/post-extubation failure.
DISCUSSION
Despite the increased amount of scientific evidence in the last 10–15 yrs, the “real life” application of NIV is only partially known. An international survey conducted in 2004 demonstrated that the use of NIV in ICUs around the world is ∼12% of the ventilated patients 5. However, in 1999 the same authors showed a much lower rate of NIV utilisation in the same ICUs, thus it was speculated that the increasing scientific evidence may have influenced this trend 5.
Geographical differences were also highlighted: the rate of NIV utilisation in certain European countries is quite high 3, while in other European Countries 11, 12 and North America 4 the NIV utilisation rate is lower.
From 1997 to 2002 an increase in NIV use was observed in French ICUs: from 16% to 24% of total ventilated patients and from 35 to 52% of patients starting ventilation in ICU 3. While in the UK in 1997, 48% of the respiratory wards were using NIV for the treatment of AHRF 12. In German ICUs, NIV use is <10% in most of the units 11, while in the USA in the New England acute-care hospitals the real life utilisation of NIV is ∼20% 4. Recently, it has also been shown that in EDs across the USA, the perceived use of NIV is <30% considering the most “popular” indications (AHRF, CPE and asthma) 13. Most of these data were collected in specific surveys concentrated in a single country/geographical area and in a single environment. Indeed, with very few exceptions 4, the studies were not focused on technological issues, such as ventilators and interfaces, which have very often been considered as one of the barriers that limit the use of NIV in real life.
In this large European, web-based survey we have demonstrated that the use of NIV, as perceived by the physicians, is relatively homogeneously spread throughout the different geographical regions and considerably high, especially among pulmonologists. We have also shown that the indications for its application are those recommended by the literature. The oro-nasal interfaces are thought to be by far the most widely used interfaces in all the clinical scenarios, while dedicated NIV ventilators or ICU ventilators with an NIV module are largely utilised.
Use of NIV and its indications
Overall, we have found that the perceived NIV use among pulmonologists is higher in Europe than among intensivists and emergency medicine physicians. It is to be noted that contrariwise to North America, pulmonologists very rarely work in ICUs and their main work facilities are either the pulmonary ward or the so-called respiratory intensive care unit, which act as a step-up unit for the ward or step-down unit for the ICU, respectively. Therefore the presumed larger use of NIV among pulmonologists may depend on various reasons, including different timing of application (i.e. preventive versus alternative to intubation use) 14, severity of patients and diseases, and the fact that many patients admitted to the ED or ICU are already intubated.
In keeping with the scientific evidence, clinicians reported AHRF as the most common indication, following by CPE, de novo respiratory failure and W/PE. Not surprisingly, pulmonologists were more likely to apply NIV in AHRF patients than intensivists, and the latter used it more often on hypoxaemic patients and during weaning, probably because these patients require closer monitoring and higher nurse/patient ratio and, therefore, need to stay in the ICU.
Use and reason for choosing a particular ventilator
ICU ventilators without an NIV module and home-care ventilators were perceived to be used very seldom during an episode of acute respiratory failure. The most frequently used machines were dedicated NIV platforms especially for AHRF and, therefore, were mainly used by pulmonologists, while ICU ventilators with an NIV module were used for other forms of acute hypoxia, mainly by intensivists. The reason for choosing a ventilator with a module able to compensate for air leaks is self-explanatory, as NIV is a semi-open ventilatory circuit where avoidance of air leaks is almost impossible and, therefore, by far the most reported side-effect 1, 2. Despite the fact that a large variation in the ability for compensating leaks among the most common ICU ventilators was demonstrated in vitro 15, 16, there is agreement that, given the same setting, machine software for NIV is able to perform extremely well.
For CPE, >20% of the respondents reported a preference for using CPAP, probably for its ease of use outside the protected environment and the possible short period of ventilation in this clinical situation.
The problem with CO2 re-breathing has always been a major concern of clinicians, especially among those dealing with hypercapnic respiratory failure; thus, the use of a double-tubing ventilator was a preferred option, despite the fact that many studies show that the intentional leak single circuit, when appropriately set, is able to minimise but not eliminate re-breathing 17, 18.
The possibility of applying a fixed and known Fi,O2has also been considered a safe feature, especially in those patients with de novo hypoxia. The measure of a correct arterial oxygen tension (Pa,O2)/Fi,O2 ratio is also important as a monitoring measure, since it may better guide clinicians’ decisions than when using a low flow system. In particular, it has been shown that the Fi,O2 actually delivered using a low-flow oxygen port in the circuit varies dramatically according to the ventilator settings, the amount of oxygen and the position of the probe, and that it may not always deliver the same value 19.
The possibility of having a good monitoring system, together with more sophisticated alarms, highlights the problem of directly assessing patient-ventilator synchronies, especially during the very first phases of NIV. The presence of patient-ventilator asynchronies, especially in intubated patients, is associated with a prolonged duration of ventilation and higher incidence of tracheotomy 20.
When NIV or any other form of mechanical ventilation is applied, medical therapy should be continued, therefore respondents considered the possibility of bronchodilators' delivery during NIV to be important. This particularly holds true in chronic obstructive pulmonary disease patients where administration of bronchodilators and steroids is a paramount intervention in an attempt to reduce elastic and resistive loads. Few studies have assessed the possibility of delivering this therapy during NIV and in vivo mainly with the double-tubing system, using the same model adopted during invasive ventilation 21, 22.
Use and reason for choosing a particular interface
There was almost unanimous agreement about the perceived use of oro-nasal masks in every clinical scenario, irrespective of the type of physician involved. This is in keeping with the literature where the large majority of studies employed this type of interface 23. It is likely that the other masks were mainly considered as a part of the “rotation strategy” when the patient showed poor tolerance to the full-face mask or in order to avoid some side-effects. In certain European countries (i.e. Italy), the helmet has been extensively used especially in the ICU, mainly for hypoxic respiratory failure and CPE 24, but overall in Europe the percentage of use is relatively small.
The main reasons for choosing a particular interface were the patient's comfort, the avoidance of leaks and the costs. The tolerance of patients to NIV is strongly related to the presence of air leaks, since it has been demonstrated that more leaks correspond to a worse compliance 25 and, in this respect, the full-face mask is much more efficient than the nasal mask 26. Cost reduction is a major goal for clinicians; therefore, it is not surprising that the economical issue was pointed out as one of the main determinants of choice. Nowadays, improvements in technology and materials employed in assembling the interfaces enable us to use rather inexpensive masks in most of the patients. However, the most severe cases may still require sophisticated and costly interfaces.
Humidification
Humidification and warming of the inspired gas by specific devices may be needed to prevent the effects due to cool, dry gases on the trachea-bronchial epithelium during NIV 27, 28. It is, therefore, rather surprising that humidification is employed in a relatively small percentage of patients (∼55%). The dichotomic nature of the question (yes/no) did not allow us to discriminate between the use of the heated humidifiers versus heat and moisture exchangers.
Strengths and limitations
The questionnaire was based, as in most of the medical surveys, on the perception of NIV use rather than on the collection of data, which may have given a more detailed and real rate of NIV use in Europe. Another limitation is the selection of respondents, mainly based on their membership to a particular group or assembly of an international Society. This may have biased the results, since the members of a scientific Society may be more exposed and eventually prone to apply the innovations in medicine 29 as NIV may be considered. In keeping with the previous point, the majority of the respondents were from a University hospital, despite the fact that the number of non-University hospitals in Europe is higher. Therefore, the data obtained in our study may be not generalised.
The major strengths of this study are the relatively high response rate for a web survey, and the possibility of having a complete response to all the questions by every respondent, as otherwise the questionnaire could not be submitted. This was not the case for other surveys where partially completed questionnaires might affect the response rate. Indeed, in this survey only one respondent per centre was allowed to participate, avoiding repetitive answers from the same unit.
Conclusions
This study indicates that the perceived NIV use is quite high in Europe, especially among pulmonologists and less frequent among intensivists, probably because of the different timings of NIV application. The indications of the perceived NIV use are in accordance with those suggested by the international guidelines. Ventilators with NIV platform are the most frequently used machines in AHRF due to chronic obstructive pulmonary disease exacerbations, while ICU ventilators with NIV module are preferably employed in de novo hypoxic respiratory failure. Overall, the full-face interfaces are the preferred choice, irrespective of the clinical scenarios.
Footnotes
Statement of Interest
Statements of interest for P. Princi and S. Nava can be found at www.erj.ersjournals.com/misc/statements.dtl
- Received August 2, 2009.
- Accepted January 4, 2010.
- ©ERS 2010