Abstract
Epidemiological studies report an association between exposure to biomass smoke and cardiopulmonary morbidity. The mechanisms for this association are unclear. The aim of the present study was to characterise the acute pulmonary and systemic inflammatory effects of exposure to forest fire smoke.
Seasonal forest firefighters (n = 52) were recruited before and/or after a day of fire-fighting. Exposure was assessed by questionnaires and measurement of carbon monoxide levels (used to estimate respirable particulate matter exposure). The pulmonary response was assessed by questionnaires, spirometry and sputum induction. Peripheral blood cell counts and inflammatory cytokines were measured to define the systemic response.
Estimated respirable particulate matter exposure was high (peak levels >2 mg·m−3) during fire-fighting activities. Respiratory symptoms were reported by 65% of the firefighters. The percentage sputum granulocytes increased significantly from 6.5 to 10.9% following fire-fighting shifts, with concurrent increases in circulating white blood cells (5.55×109 to 7.06×109 cells·L−1) and band cells (0.11×109 to 0.16×109 cells·L−1). Serum interleukin (IL)-6, IL-8 and monocyte chemotactic protein-1 levels significantly increased following fire-fighting. There were no changes in band cells, IL-6, and IL-8 following strenuous physical exertion without fire-fighting. There was a significant association between changes in sputum macrophages containing phagocytosed particles and circulating band cells.
In conclusion, acute exposure to air pollution from forest fire smoke elicits inflammation within the lungs, as well as a systemic inflammatory response.
Fine particles are thought to be the best single indicator of the health impacts of most combustion sources. Numerous epidemiological studies have documented a detrimental relationship between exposure to particulate matter in urban air pollution and cardiopulmonary morbidity and mortality with both short- and long-term exposure 1–5. Although the mechanism by which exposure to particles in urban air induces adverse cardiopulmonary effects remains unclear, several studies from the present authors’ laboratory and others support a mechanism in which exposure to fine particles promotes inflammation in the lung 6–11 via activation of alveolar macrophages and lung epithelial cells 12–16. Such exposure is also associated with a systemic inflammatory response 17–20, which in turn is associated with an increased presence of several cytokines (interleukin (IL)-6, IL-1β) in the bloodstream 21 as well as increased production and release of polymorphonuclear leukocytes (PMN) and monocytes from the bone marrow 17–20.
In contrast to the large amount of information relating urban particulate matter to human health impacts, there are a limited number of studies directly evaluating the mechanisms of the health impacts of wood smoke. While wood smoke contains high concentrations of both particulate matter and gaseous compounds, wood smoke particles are similar in size to urban combustion-generated particles, and within the respirable size range that is thought to be most damaging to human health 22. Epidemiological and toxicological evidence of the adverse effects of wood smoke have recently been reviewed by Naeher et al. 21 and support several other studies indicating that increases in cardiopulmonary morbidity are related to smoke from forest fires and biomass burning 23–27. For example, health impact surveillance during severe forest fires in Southeast Asia in 1997 (where particles were the main pollutant) showed a 30% increase in outpatient medical attendance for haze-related conditions in the general population of Singapore 25. All-cause mortality increased by 19% in certain highly polluted regions, with the most prominent effect in the elderly population, in which deaths due to nontraumatic causes increased by 70% 27.
Wildland firefighters experience greater exposure from forest fire smoke than members of the general public. They frequently have prolonged and direct exposure to smoke, and elevated pulmonary ventilation rates can result in substantial doses of smoke to the respiratory tract. Reinhardt and Ottmar 28 showed that firefighters were exposed to high levels of respirable particles (particulate matter ≤3.5 μm (PM3.5)) with peak concentrations ranging 2.3–2.9 mg·m−3.
Given the high smoke exposures experienced by firefighters and the epidemiological evidence indicating association between exposure to wood smoke and adverse health 23–27, the present authors postulated that acute exposure to smoke from forest fires provokes a local inflammatory response in the lungs and stimulates a measurable systemic inflammatory response. In order to test this hypothesis, healthy seasonal firefighters from the British Columbia Forest Service (BCFS) were recruited before the fire season, when relevant parameters of health (questionnaires), lung function (spirometry), lung inflammation (sputum induction) and systemic inflammation (blood cell counts and circulating cytokines) were collected. Collection of these parameters was repeated during the fire season immediately after a day of active duty within fire zones. Preliminary results of the present study have previously been published 29.
METHODS
Subjects recruitment and sampling
Seasonal BCFS forest firefighters were recruited during the 2004 and 2005 fire seasons (May–August). Healthy nonsmoking firefighters 17–60 yrs of age were eligible for inclusion. Exclusion criteria were: a prior diagnosis of, or ongoing evaluation for, any chronic medical condition; regular use of prescription medications; pregnancy or lactation; or any upper respiratory tract symptoms consistent with infection or inflammation in the 4 weeks prior to enrolment. The study was approved by the institutional ethics committee (St Paul’s Hospital, University of British Columbia, Vancouver, BC, Canada) and written consent was obtained from all subjects.
Baseline data were collected in training camps before firefighters were dispatched to fire zones. Stress control data were collected after firefighters had spent a work shift (∼8 h) engaged in strenuous physical activity (similar to physical activity during fire-fighting) with no exposure to forest fire smoke. Post-exposure measurements were made within 4 h after completing fire-fighting shifts. Both baseline (12:00–17:00 h) and post-exercise and fire-fighting samples (16:00–20:00 h) were collected in the afternoon or early evening. Subjects completed surveys detailing work shift activities and smoke exposure. Sputum induction, spirometry and blood sampling by peripheral venopuncture was performed. Selected participants were assigned to carry portable carbon monoxide monitors (Pac III; Dräger, Mississauga, ON, Canada) during their work shift. Carbon monoxide monitors were distributed by the crew leader to study participants performing different fire-fighting tasks in an attempt to obtain representative sampling. The monitors recorded ambient carbon monoxide levels every 5 min. Particulate matter was not directly measured due to BCFS regulations prohibiting access to fire zones to collect samples and the lack of sufficiently rugged, small and lightweight continuous personal particulate matter sampling equipment. Instead, carbon monoxide concentrations were measured as a surrogate based on the recommendations of Reinhardt and Ottmar 30, who have previously shown that carbon monoxide exposures are highly correlated with respirable particle exposures of firefighters. Measured carbon monoxide exposures were then converted to estimated respirable particlulate matter concentrations based upon the regression equations published by Reinhardt and Ottmar 30.
Sputum induction and spirometry
Spirometry was performed according to American Thoracic Society criteria 31 using a single spirometer (EasyOne Spirometer; ndd Medical Technologies, Zurich, Switzerland). Induced sputum was performed using techniques described previously 32. Samples were stored and processed using methods described by Efthimiadis et al. 33 and modified by Kelly et al. 34. Sputum induction and sample preparation are described in detail in the supplementary data. Under a light microscope at 630× magnification cells were classified as granulocytes, monocytes, lymphocytes, macrophages or bronchial epithelial cells. Macrophages were subdivided into those with no visible inclusions and those with less than, or greater than, 5% of their cytoplasm containing dust particles, labelled as negative, low-positive or high-positive macrophages, respectively, as described in detail previously 8. Sputum cell counts were assessed by a trained technician blinded to the clinical details of the subjects.
Peripheral blood analysis
Complete blood counts were performed on whole blood samples using a Cell-Dyn 3700 Hematology Analyzer (Abbott Diagnostics, Mississauga, ON, Canada). Band cell counts were manually performed by a trained technician blinded to the clinical details of the subject, on thin blood smears that were air dried, fixed with methanol and stained with Wright stain. Serum IL-6 and IL-8 concentrations were measured using commercial ELISA assays (R&D Systems, Minneapolis MN, USA and Linco Research, St. Charles, MO, USA, respectively).
Statistical analysis
Data are expressed as mean±sem. Differences between baseline and fire-fighting values were evaluated using paired t-tests. Differences between multiple groups (baseline, exercise and fire-fighting) were compared by one-way ANOVA. The post hoc test for a multiple comparison was the Fisher's protected least significant difference test. Spearman rank correlations were performed to assess the relationship between lung and systemic circulation. A p-value of 0.05 was considered to be statistically significant.
RESULTS
Subject recruitment and sampling
A total of 52 firefighters were enrolled in the study and underwent sampling either in training camps (baseline), after a day of fire-fighting (exposure) or after a day of physical activity without smoke exposure (exercise). Both baseline and exposure samples were obtained in 34 subjects (paired sampling). In nine subjects baseline, exercise and exposure samples were obtained. Basic demographic characteristics of firefighters enrolled in the study are shown in table 1⇓. The majority of firefighters were young males of either Caucasian or Canadian First Nations descent. All subjects were free from acute or chronic medical comorbidities (including any history of allergies or asthma) and all were nonsmokers or ex-smokers (defined as both: 1) quit >6 months; and 2) not more than 5 pack-yrs of smoking) at the time of enrolment.
Smoke exposure and respiratory symptoms
Forest fires from which samples were obtained were in remote regions away from major roadways. Figure 1⇓ shows firefighters’ qualitative perception of smoke exposure during their work shift on the day of sampling. The majority report light or medium smoke exposure and, on average, <10% of the work shift was spent in conditions of heavy smoke. Carbon monoxide monitors carried by 17 firefighters during two separate forest fires showed workshift carbon monoxide levels to fluctuate predominately in the range 5–20 ppm with a background carbon monoxide level in the fire zone base camps of 1–5 ppm (fig. 2⇓). Figure 2⇓ shows the estimated respirable PM3.5 exposure of firefighters, with peak levels of 2.8 mg·m−3 and 6 h of levels >1 mg·m−3 during a work shift. Post-exposure questionnaires were completed by 45 firefighters. In response to smoke exposure, 65% of firefighters reported one or more respiratory symptom. The most common complaints were cough (24.4%), sputum production (28.9%) and nasal congestion (20.0%; table 2⇓). All reported symptoms were minor and no symptoms required acute medical intervention.
Spirometry
Spirometry before and after fire-fighting was obtained in 23 subjects. Forced expiratory volume in one second (FEV1; pre- and post-bronchodilation with 200 μg salbutamol) performed at baseline and after fire-fighting shifts were not different. The changes in FEV1 following sequential inhalation of escalating concentrations of saline (3, 4 and 5%) are shown in figure 3⇓. After inhalation of 3% hypertonic saline there was a small fractional decrease in the post-exposure group (n = 12) that was not seen in pre-smoke exposure testing, but this change did not reach significance. After inhalation of 4% saline, the difference in the fractional FEV1 change between the two groups diminished and then disappeared with inhalation of 5% saline.
Sputum analysis (lung inflammation)
Of the 34 subjects with paired sputum samples obtained at baseline and after exposure, 23 fulfilled the criteria for adequate specimens 33 in both samples. An increase in the percentage of sputum granulocytes in nonsquamous cells was observed following fire-fighting shifts, from 6.48±1.23% at baseline to 10.87±1.36% post-exposure (p<0.02; fig. 4a⇓). The total macrophage fraction in the sputum samples did not change with smoke exposure (fig. 4b⇓); however, there was a small but statistically significant increase in inclusion-positive macrophages of 5.00±1.34 to 9.74±1.60% (p<0.03; fig. 4c⇓). The fraction of inclusion-negative macrophages decreased following smoke exposure (75.65±2.31 to 65.78±2.85%; p<0.01) with a concurrent increase in the fraction of low positive-inclusion containing macrophages (4.83±1.29 to 9.39±1.49%; p<0.03; fig. 4d⇓) with no change in the percentage of high-positive macrophages in the sputum samples (fig. 4d⇓). Sputum lymphocyte, monocyte and bronchial epithelial cells did not show a significant change following smoke exposure (data not shown).
Peripheral blood analysis (systemic inflammation)
Circulating total white cell counts, differentials and band cell counts were compared before and after fire-fighting shifts. Total white blood cell counts increased following fire-fighting shifts from 5.55±017 to 7.06±0.18×109 cells·L−1 (n = 34; p<0.0001; fig. 5a⇓). Circulating PMN counts also increased after firefighting shifts (from 3.32±0.15 to 4.15±0.15×109 cells·L−1; p<0.001), as did band cell counts (from 0.11±0.011 to 0.16±0.015×109 cells·L−1; p<0.01; fig. 5b⇓). Similar results were obtained in the unpaired analysis comparing all baseline samples to those collected post-exposure (data not shown). There were no significant changes in any other peripheral blood cell indices including haemoglobin, platelet counts and other white blood cell subpopulations (data not shown). Post-exposure serum IL-6 and IL-8 levels were elevated from baseline with IL-6 increasing from 0.82±0.12 to 1.89±0.43 pg·mL−1 (n = 34; p<0.02; fig. 5c⇓) and IL-8 increasing from 14.02±3.48 to 45.03±8.32 pg·mL−1 (n = 14; p<0.001; fig. 5d⇓). There were no increase in circulating granulocyte-macrophage colony-stimulating factor levels with exposure although there was a small but statistically significant increase in monocyte chemotactic protein (MCP)-1 levels (from 179±19.9 to 260±24.1 pg·mL−1; p<0.02). C-reactive protein (CRP) did not increase with smoke exposure (data not shown). The changes in circulating band cells with smoke exposure correlate with the changes in macrophages containing particulate inclusions (r2 = 0.28, p<0.03; fig. 6a⇓) and changes in circulating IL-6 correlated with changes in the fraction of granulocytes in the sputum (r2 = 0.29, p<0.05; fig. 6b⇓).
To determine whether the changes seen in the circulation were due to a stress response rather than smoke exposure, nine subjects underwent sequential sampling at baseline and following shifts. This involved strenuous activity (similar to activities done during fire-fighting) in the absence of smoke exposure (exercise controls). Compared with baseline testing, exercise increased circulating white blood cell counts (from 5.60±0.33 to 7.23±0.33×109 cells·L−1; p<0.001; fig. 7a⇓) and PMN counts (3.48±0.28 to 4.89±0.37×109cells·L−1; p<0.02). However, neither band cell counts nor IL-6 or IL-8 levels changed significantly following strenuous exercise compared with baseline testing (fig. 7b–d⇓).
DISCUSSION
The majority of epidemiological and biochemical studies linking air pollution to respiratory and cardiovascular disease have focused on urban sources 1–5. Exposure to urban air pollution is associated with an inflammatory response in the lung that is thought to be responsible for the adverse respiratory health effects, while the associated systemic inflammatory is implicated in adverse cardiovascular effects 35–39. Although exposure to air pollution from biomass burning remains a significant problem in both developed countries (exposure during wildland fire-fighting, in communities in proximity to wildland fires and from residential wood smoke) and developing nations (exposure from indoor cooking and agricultural burning) 21, the mechanisms of the adverse heath effects of biomass smoke inhalation have not been as rigorously studied to date. The present study has demonstrated that inhalation of smoke from forest fires by young healthy firefighters induces a measurable inflammatory response in the lung characterised by an increase in sputum granulocytes. These changes were associated with symptoms of both upper and lower respiratory tract irritation. Additionally, systemic inflammation, characterised by stimulation of the bone marrow (increased circulating band cells) and increased circulating cytokine levels, was found. Such local and systemic inflammatory responses may contribute to the observed adverse health effects reported in epidemiological studies of those exposed to smoke from forest fires 21, 23, 24.
Carbon monoxide monitoring was used in the present study in order to confirm the presence of ambient smoke on the day when post-shift samples were collected (fig. 2⇑). Carbon monoxide has been previously shown to correlate with major constituents of biomass smoke such as acrolein, benzene, formaldehyde and respirable particulate matter, and is therefore a quantitative indicator of smoke exposure 30, 40. Based on those previous studies and the measured carbon monoxide exposures in the present study, high exposures to particulate matter during fire-fighting were estimated. The estimated exposure to combustion-source respirable particles, in the 1–2 mg·m−3 range, are similar to those experienced by females and children in developing countries who cook with biomass over open fires, and more than one order of magnitude above concentrations of ambient fine particles found in highly polluted cites or in communities impacted by forest fire smoke 21. While the observed effects in the present study may be attributed to exposures other than to particulate matter, the increase in sputum macrophages with carbon inclusions confirms increased inhalation of airborne particulate matter in the exposure group compared with baseline sampling. The largest increase was seen in the macrophages with few particle inclusions, suggesting mild to moderate exposure. Alternatively, the low particle load of macrophages could also be due to impaired macrophage phagocytic ability following exposure to airborne particulate matter, as previously reported by Rudell et al. 11.
The majority of symptoms reported by the firefighters in the present study were relatively mild complaints related to irritation of the respiratory tract. These findings are consistent with previous studies that have shown an increase in respiratory symptoms, including nasal irritation, cough, sputum production and wheezing 24, 41. The clinical importance of this respiratory irritation may be minor in the present study population, which was comprised of health subjects with no underlying respiratory conditions. However, in “at-risk” subjects with conditions such as asthma and chronic obstructive pulmonary disease, this upper and lower respiratory tract irritation may be sufficient to exacerbate the lung condition. This is supported by the significant increase in outpatient visits and hospitalisations for respiratory illnesses in children, during the forest fires of Southern California, USA 24, and in both Singapore 25 and Indonesia 26 in 1997.
In the present study, a decline in FEV1 with exposure to forest fire smoke was not demonstrated. Additionally, a significant degree of airway hyperreactivity induced by hypertonic saline inhalation in post-exposure testing was not detected. This differs from the findings of other studies; several have shown a small decline in pulmonary function (FEV1 and forced vital capacity) associated with exposure to wildfire smoke 40, 41. Betchley et al. 40 have also reported a small but persistent post-season decrement in FEV1 and mean forced expiratory flow between 25 and 75% of forced vital capacity, 2.5 months after cessation of fire-fighting activity; this suggests that the respiratory effects of forest fire smoke inhalation last long after exposure is resolved. The discrepancy between the present findings and those of previous studies may also be related to the relatively low degree of accumulated exposure in the present study. Furthermore, a larger study would be necessary in order to establish whether acute exposure of healthy nonasthmatic subjects (such as those in the present study) to wild fire smoke induces airway reactivity.
Analysis of induced sputum samples showed an increase in the fraction of granulocytes (mostly neutrophils) in sputum samples following smoke exposure. This suggests recruitment of granulocytes into the airway and is consistent with numerous previous studies in both animals 42–46 and humans 7, 9–11, which have shown increased granulocyte counts, most commonly neutrophilia, in bronchoalveolar lavage and induced sputum samples following exposure to particulate matter. An increase in the number of macrophages in induced sputum was not found in the present study, which suggests that the predominant inflammatory response in the lung with acute wood smoke exposure is neutrophilic in nature.
Airspace macrophages that phagocytose airborne particles are not only capable of eliciting a local inflammatory response in the lung, but also contribute to the initiation of a systemic inflammatory response 17, 18, 20. In the present study, a significant increase in circulating white blood cells, PMN and band cell counts following fire-fighting shifts has been demonstrated. Band cells are immature PMN produced in the bone marrow; an increase in band cell count in the peripheral circulation is an indication that the marrow has been stimulated to increase the release of granulocytes 47. This bone marrow stimulation, induced by forest fire smoke exposure, is consistent with animal studies that have shown an increase in circulating band cell counts following exposure to ambient air pollution particles 17–19. In addition, these same animal studies provided further evidence for stimulation of the bone marrow by demonstrating a decrease in the transit time of PMN cells and monocytes through the bone marrow after exposure to ambient particles 17–19. Bone marrow stimulation induced by exposure to air pollutants is also supported by the study of Tan et al. 47, which showed an increase in circulating band cell counts in healthy army recruits exposed to smoke haze during the 1997 Southeast Asian forest fires.
In order to further support the idea that biomass smoke exposure induces a systemic inflammatory response, the present study showed elevated levels of circulating cytokines (IL-6, IL-8 and MCP-1) in firefighters following smoke exposure (fig. 5⇑). IL-6 is considered an important multifunctional cytokine involved in the regulation of a variety of cellular responses, including the induction of acute-phase protein synthesis, lymphocyte activation and haematopoiesis 48. It has been shown previously that IL-6 is a potent stimulator of the bone marrow that increases the transit of PMN and monocytes through the marrow and their release into the circulation 49. IL-6 also promotes the sequestration of PMN in the lung 50 in a similar manner to that of IL-8 51. IL-6 has also been shown to play an important role in the pathogenesis of atherosclerosis either directly via the release of platelets from the marrow, or indirectly by increasing acute phase proteins such as CRP and fibrinogen 52, 53. In the present study, CRP was not elevated following exposure, suggesting that IL-6 alone is insufficient to increase circulating CRP levels following wood smoke exposure. Changes in the fraction of macrophages with particle inclusions correlated with changes in band cell counts (fig. 6a⇑) and circulating IL-6 correlates with the increase in airspace granulocytes (fig. 6b⇑) following exposure. This suggests that lung inflammation impacts systemic inflammation. Furthermore, the similarity of mediators produced by macrophages exposed to particles 12, 17, 18, 20 and increased circulating mediators suggests that these cells are critically important in generating the systemic inflammatory response induced by exposure to wood smoke.
It is known that vigorous exercise is associated with an increase in circulating white blood cells and PMN counts, largely due to mobilisation of these cells from the intravascular marginated pool by catecholamines 54. In a subgroup of nine firefighters, an increase in circulating white blood cell and PMN counts, equivalent to those seen following smoke exposure, was induced by strenuous exercise without smoke exposure. Therefore, the increase in white blood cell and PMN counts appears to be part of a nonspecific stress response and not a feature unique to smoke inhalation. The absence of an increase in band cell counts, IL-6 and IL-8 in the exercise control samples suggests that the increase in band cells post-exposure is not a stress response due to the physical exertion of fire-fighting, but rather a unique response to forest fire smoke inhalation. Collectively, the increase in peripheral band cell counts, as well as serum IL-6 and IL-8 levels, following exposure to forest fire smoke provides evidence for stimulation of the bone marrow and the initiation of a systemic inflammatory response as a consequence of smoke inhalation.
In summary, the present study has shown that healthy seasonal forest firefighters exposed to biomass smoke mount both a pulmonary and systemic inflammatory response. Examination of forest firefighters exposed to wildfire smoke provides a unique opportunity to specifically assess the acute effects of biomass air pollution as well as furthering the understanding of the toxicity of particulate matter air pollution in humans in general. The present results provide a plausible mechanism for the increased cardiopulmonary morbidity and mortality that epidemiological studies have associated with air pollution from biomass smoke inhalation. The findings also support a growing body of research showing that inhalation of particulate matter from a variety of sources generates a local inflammatory response within the lungs, which subsequently initiates a systemic response resulting in the adverse health consequences associated with air pollution exposure. These adverse health effects may be of little clinical consequence for young healthy firefighters; however in susceptible subjects exposed to wildfire smoke they could trigger exacerbations of asthma and chronic obstructive pulmonary disease, predispose to lung infection or precipitate acute cardiac events 53, 55. The long-term consequences of smoke exposure for seasonal firefighters is less well studied but there is clearly a need for methods to reduce it, in order to attenuate both the local (lung) and systemic effects of exposure to wildfire smoke.
Support statement
The present study was supported by grants from the Heart and Stroke Foundation of Canada, Wolfe and Gina Churg Foundation and the British Columbia Lung Association. S. F. van Eeden is an American Lung Association Career Investigator, the recipient of the William Thurlbeck Distinguish Research Award and the Michael Smith Foundation Senior Investigators Award.
Statement of interest
A statement of interest for M. Brauer can be found at www.erj.ersjournals.com/misc/statements.shtml
Acknowledgments
The present authors would like to thank British Columbia Forest Services for their cooperation and generous support to make this study possible.
Footnotes
-
This article has supplementary material accessible from www.erj.ersjournals.com
- Received July 31, 2007.
- Accepted January 28, 2008.
- © ERS Journals Ltd