Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions

The autoclavable semirigid thoracoscope: the way forward in pleural disease?

M. Munavvar, M. A. I. Khan, J. Edwards, Z. Waqaruddin, J. Mills
European Respiratory Journal 2007 29: 571-574; DOI: 10.1183/09031936.00101706
M. Munavvar
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. A. I. Khan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Edwards
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Z. Waqaruddin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Mills
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Medical thoracoscopy is a valuable tool in the investigation and management of pleural disease. It has considerable advantages over conventional blind pleural biopsy and video-assisted thoracoscopic surgery. Despite this, the practice of this technique in the UK is limited. Most operators use the rigid thoracoscope, which may be an unfamiliar instrument to respiratory physicians. A semirigid thoracoscope is available but its use has not been possible in the UK as it requires sterilisation with ethylene oxide, which is not approved in this country. The present authors describe herein their experience with the first ever autoclavable semirigid thoracoscope.

Medical thoracoscopy using the new instrument was performed in 56 patients between June 2004 and May 2006. All patients had been referred with a unilateral pleural effusion of unknown aetiology, where blind pleural aspiration had failed to yield an answer. Diagnostic samples were taken and talc poudrage performed where appropriate.

The instrument was easy to handle and excellent views were obtained. Histologically adequate biopsy samples were obtained in 54 patients. The combination of clinical features, computed tomography findings and thoracoscopic biopsy enabled a definite diagnosis in 49 (90.7%) of these patients. There were no complications.

The autoclavable semirigid thoracoscope has immense potential in the diagnosis and management of pleural disease. Its diagnostic yield in pleural disease is comparable to the conventional rigid thoracoscope. It is similar in design to the fibreoptic bronchoscope and respiratory physicians should be able to adapt to its use easily. It is also compatible with existing video processors and light sources available in most endoscopy suites. The fact that this instrument is autoclavable should open the field for its use in the UK as well as in other countries.

  • Malignancy
  • pleural biopsy
  • pleurodesis
  • semirigid
  • thoracoscopy

The accurate diagnosis of pleural disease can present a considerable challenge. After thoracocentesis and/or blind pleural biopsy, ∼25–40% of pleural abnormalities remain undiagnosed 1, 2. Medical thoracoscopy refers to the examination of the pleural space in a nonintubated patient under conscious sedation 3. It enables inspection of the pleural surfaces, the taking of pleural biopsies under direct vision, therapeutic drainage of effusions and pleurodesis in one sitting. It enables a positive diagnosis in >90% of pleural effusions 4, 5. It is very well tolerated and there is no requirement for a general anaesthetic, as opposed to video-assisted thoracoscopic surgery (VATS).

Despite its obvious benefits, the practice of thoracoscopy in the UK, and indeed in most parts of the world, is not widespread 6, 7. A reason suggested for this is that most respiratory physicians are not familiar with the use of the more commonly used rigid thoracoscope 8. The procedure has been attempted with the flexible bronchoscope but this is difficult to manipulate within the pleural cavity and results have been inferior to the rigid instrument 9, 10.

The semirigid thoracoscope was developed in an attempt to combine the best features of the flexible and rigid instruments 3. However, the use of this instrument in the UK has not been possible as it requires sterilisation with ethylene oxide, the use of which is not allowed in the UK.

The present authors describe their experience with the first ever autoclavable semirigid thoracoscope. This instrument is compatible with the video processors and light sources available in most bronchoscopy units.

MATERIALS AND METHODS

The present study was a single-centre study and included consecutive patients referred over an 18-month period with a unilateral pleural effusion and a negative or unsuccessful blind pleural fluid aspirate. All patients had a contrast computed tomography (CT) scan of the thorax before entry. Patients with “highly suspicious” pleural fluid cytology were not entered into the study unless the cytological diagnosis was at variance with clinical features and CT findings. All patients with merely “suspicious” or “normal” cytology were included in the study group.

The instrument employed was a prototype semirigid thoracoscope (LTF-160Y1; Olympus, Tokyo, Japan; supplied by Olympus KeyMed UK, Southend-on-Sea, UK). It has controls similar to that of a flexible fibreoptic bronchoscope. The total length of the instrument is 52 cm, with the insertion portion being 27 cm long. Of this, the proximal 22 cm are rigid and the distal 5 cm are flexible. The external diameter of the insertion portion is 7 mm. The tip is bendable in one plane, with an upward angulation of 160° and downward angulation of 130° (fig. 1⇓). The 2.8-mm inner working channel accommodates the biopsy forceps and other instruments. It has an yttrium-aluminium-garnet 810-nm diode laser and high-frequency compatibility. It is compatible with the EVIS EXERA 160 and 145 and EVIS 100 and 140 Series video processors and light sources (Olympus). Sterilisation is achieved by autoclaving.

Fig. 1—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1—

The instrument (a) has a flexible tip (b), as shown.

Procedure

All procedures were performed by a single operator (M. Munavvar) in the endoscopy suite of the present authors’ institution (Royal Preston Hospital, Preston, UK). Informed consent was obtained in writing. A single puncture technique was used. Full surgical aseptic technique was adhered to. The lateral decubitus position was employed, with the diseased side up. All patients received combination sedation with intravenous midazolam and alfentanil; oxygen saturations and heart rate were monitored throughout. Patients received supplementary oxygen by nasal cannulae routinely.

Lignocaine was employed for local anaesthesia. The presence of fluid was first confirmed by aspiration; if this failed, the patient's position was changed and aspiration was attempted again. After fluid was obtained, an incision was placed in the midaxillary line and a 10-mm trocar inserted. The thoracoscope was then inserted and, following drainage of all fluid to dryness, the pleural surfaces were inspected. Pleural fluid and parietal pleural biopsy samples were obtained where indicated. Between six and 10 biopsies were taken per patient. An FB-240K oval fenestrated biopsy forceps (Olympus) was used. Talc poudrage with 5 g sterile talc (Novatech, La Ciotat, France) was carried out where appropriate. A 24F chest drain (Portex; Smiths Medical International Ltd, Hythe, UK) was inserted through the trocar. All patients underwent a chest radiograph after the procedure. The chest tube was removed as soon as full expansion of the lung was confirmed radiologically.

The operator recorded the image quality, the presence of pleural abnormalities on inspection, the duration of chest drainage after the procedure and the occurrence of complications.

RESULTS

Between June 2004 and May 2006, 60 procedures were attempted on 59 patients. Three procedures were abandoned before insertion of the trocar as no fluid was obtained on initial aspiration despite multiple attempts. Hence, 57 procedures were performed on 56 patients. The indication in all the procedures was a unilateral pleural effusion of unknown cause, with no diagnosis on blind pleural fluid aspiration. The median age of the patients was 68.5 yrs. The range of ages was 20–90 yrs, with 19 patients aged ≥75 yrs. There were 37 males and 19 females.

The thoracoscope was found to be easy to handle. The image quality was uniformly excellent (fig. 2⇓) and fluid was suctioned without difficulty. In two patients, extensive adhesions precluded satisfactory inspection and hence adequate biopsies could not be taken. Several other patients had moderate adhesions but the flexible tip was easily manoeuvred round them, enabling inspection and biopsy. Adequate inspection of the pleural cavity was undertaken in 54 patients; in all but one of these, histologically satisfactory biopsy samples were obtained. This patient, who was only the third to be examined, underwent a repeat procedure at which a satisfactory sample was taken.

Fig. 2—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2—

Images taken using the thoracoscope showing a) normal pleura, b) tuberculosis, c) mesothelioma, d) mesothelioma with adhesions, e) adenocarcinoma and f) talc poudrage.

In the end, satisfactory biopsy samples were obtained in 54 patients. The combination of clinical features, contrast CT scanning and thoracoscopic inspection/biopsy enabled a definite diagnosis in 49 of these, giving a positive yield of 90.7% (table 1⇓).

View this table:
  • View inline
  • View popup
Table 1—

Final diagnosis in patients undergoing thoracoscopy with adequate sampling

In the two patients found to have empyema, this diagnosis had not been suspected before thoracoscopy and was only established after purulent fluid was obtained with the instrument. In all the patients with a nonmalignant diagnosis on histology, there was no reason to suspect malignancy on clinical or CT grounds, and hence no indication for further investigation with thoracotomy.

The patients with histological diagnoses of inflammation, fibrosis and normal pleura had a prior history suggestive either of infection or of asbestos exposure, except one who was known to have rheumatoid arthritis. The final clinical diagnoses in these patients were therefore post-pneumonic effusion, benign asbestos-related pleural effusion and rheumatoid effusion. The subsequent clinical course of these patients has given no cause to believe otherwise.

For the five patients where no diagnosis was obtained from thoracoscopy despite satisfactory sampling, the following events occurred. 1) The first patient had considerable adhesions. Metastatic adenocystic salivary gland carcinoma was ultimately diagnosed on ultrasound-guided pleural biopsy. 2) In the second patient, there was a prior history of colorectal carcinoma. Metastatic colorectal carcinoma was ultimately diagnosed by gastro-intestinal and gynaecological investigations. 3) The third patient was known to have had gastric non-Hodgkin's lymphoma in the past. With no answer forthcoming from thoracoscopy, a clinical decision to treat for relapsed lymphoma was made. With treatment, the patient's pleural disease completely resolved. 4) One patient was diagnosed with nonsmall cell lung cancer by transbronchial needle aspiration. 5) The remaining patient proceeded to a VATS biopsy, which was also negative. The patient eventually underwent a thoracotomy. Adenocarcinoma of the lung was diagnosed.

All patients tolerated the procedure well. Pharmacological reversal of sedation was not required in any cases. There were no complications and no mortality. The chest drain was removed within 24 h in the majority and 48 h in all patients.

DISCUSSION

When faced with the need to obtain a pleural biopsy specimen, many UK physicians resort to a blind procedure with the Cope or Abrams needle. Blind pleural biopsy has a notoriously poor yield and patients in whom no result is obtained are often referred for a VATS procedure 1, 2. This is expensive and requires general anaesthesia with single lung ventilation and the use of an operating theatre. In the UK, access to VATS is limited due to the relatively small number of surgeons who practise it and often patients have to wait an unacceptably long period of time for a procedure. In addition, patients with advanced pleural disease are often frail with multiple comorbidities and may not be suitable for a general anaesthetic in the first place.

The British Thoracic Society (BTS) recommends either thoracoscopy or image-guided biopsy (using CT or ultrasound) as the next line of investigation in the event of a nondiagnostic blind pleural aspirate 11. CT-guided biopsy is safe, with the only reported complications being local haematoma and minor haemoptysis. It was found to be quite sensitive (87%) in a series of 50 patients 12. Unfortunately, it does not afford the opportunity for drainage of pleural fluid or pleurodesis in the same sitting. Indeed, the BTS recommends thoracoscopy in the event of image-guided biopsy not yielding an answer.

Medical thoracoscopy is extremely safe, with major and minor complication rates of 1.9 and 5.6%, respectively, in one series 13. Death as a complication is extremely rare, with only one fatality out of 8,000 patients in one series 14. Thoracoscopy also offers the opportunity to perform diagnostic sampling, aspiration of fluid and talc poudrage in the same setting. In-patient stay is remarkably short.

The practice of medical thoracoscopy in the UK remains limited, for reasons already discussed. Indeed, a 2004 survey showed that only 14% of UK respiratory physicians had any exposure to it at all, and only 6% had performed >10 procedures 6.

The semirigid instrument used in the present study may offer a way forward. It appears to have some advantages over the rigid thoracoscope. With its similarity in design to the flexible bronchoscope, it is hoped that chest physicians will be able to adapt to its use without too much difficulty, although formal training is essential 8. It is easy to manoeuvre within the pleural cavity. It is compatible with standard biopsy forceps and can be used with the processors and light sources found in most endoscopy rooms.

Undoubtedly, the biopsy size from the rigid thoracoscope is larger than with the semirigid instrument. This has been quoted as a reason for the former's superiority. However, smaller biopsy size does not necessarily translate to inferior diagnostic yield; indeed, the present authors’ results, as well as those of other operators, have been excellent 3, 15. The fact that the instrument used can be autoclaved is a huge bonus and it opens the way for its wider use both in the UK and abroad.

Overall, there is immense potential for the use of the autoclavable semirigid thoracoscope in the speedy and accurate diagnosis and effective management of pleural disease.

  • Received August 3, 2006.
  • Accepted December 19, 2006.
  • © ERS Journals Ltd

References

  1. ↵
    Poe RH, Israel RH, Utell MJ, et al. Sensitivity, specificity, and predictive values of closed pleural biopsy. Arch Intern Med 1984;144:325–328.
    OpenUrlCrossRefPubMedWeb of Science
  2. ↵
    Prakash UBS, Relman H. Comparison of needle biopsy with cytologic analysis for the evaluation of pleural effusion: analysis of 414 cases. Mayo Clin Proc 1985;60:158–164.
    OpenUrlCrossRefPubMedWeb of Science
  3. ↵
    Ernst A, Hersh CP, Thurer R, et al. A novel instrument for the evaluation of the pleural space. Chest 2002;122:1530–1534.
  4. ↵
    Canto A, Blasco E, Casillas M, et al. Thoracoscopy in the diagnosis of pleural effusion. Thorax 1977;32:550–554.
    OpenUrlAbstract/FREE Full Text
  5. ↵
    Weissberg D, Kaufmann M. Diagnostic and therapeutic pleuroscopy. Experience with 27 patients. Chest 1980;78:732–735.
  6. ↵
    Munavvar M, Shakur R, Corless M, Singh H, Guirguis A. Survey of the practice of interventional bronchoscopy in UK. Thorax 2004;59: Suppl. II P76
    OpenUrl
  7. ↵
    Burrows NJ, Ali NJ, Cox GM. The use and development of medical thoracoscopy in the United Kingdom over the past 5 years. Respir Med 2006;100:1234–1238.
    OpenUrlCrossRefPubMedWeb of Science
  8. ↵
    Mathur PN. Pleuroscopy: a window to the pleura. J Bronchol 2004;11:147–149.
    OpenUrlCrossRef
  9. ↵
    Oldenburg FA Jr, Newhouse MT. Thoracoscopy. A safe, accurate diagnostic procedure using the rigid thoracoscope and local anesthesia. Chest 1979;75:45–50.
  10. ↵
    Davidson AC, George RJ, Sheldon CD, et al. Thoracoscopy: assessment of physician service and comparison of a flexible bronchoscope used as a thoracoscope with a rigid thoracoscope. Thorax 1988;43:327–332.
    OpenUrlAbstract/FREE Full Text
  11. ↵
    Maskell NA, Butland RJA. on behalf of the British Thoracic Society Pleural Disease Group. BTS guidelines for the investigation of a unilateral pleural effusion in adults. Thorax 2003;58: Suppl. II ii8–ii17.
    OpenUrlAbstract/FREE Full Text
  12. ↵
    Maskell NA, Gleeson FV, Davies RJO. Standard pleural biopsy versus CT-guided cutting-needle biopsy for diagnosis of malignant disease in pleural effusions: a randomised controlled trial. Lancet 2003;361:1326–1330.
    OpenUrlCrossRefPubMedWeb of Science
  13. ↵
    Menzies R, Charbonneau M. Thoracoscopy for the diagnosis of pleural disease. Ann Intern Med 1991;114:271–276.
    OpenUrlCrossRefPubMedWeb of Science
  14. ↵
    Boutin C, Viallat JR, Cargnino P, et al. Thoracoscopy in malignant pleural effusion. Am Rev Respir Dis 1981;124:588–592.
    OpenUrlPubMedWeb of Science
  15. ↵
    Khan MAI, Ambalavanan S, Munavvar M, et al. A comparison of the diagnostic yield of rigid and semirigid thoracoscopes. Eur Respir J 2006;28: Suppl. 50 970s
    OpenUrl
PreviousNext
Back to top
View this article with LENS
Vol 29 Issue 3 Table of Contents
European Respiratory Journal: 29 (3)
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The autoclavable semirigid thoracoscope: the way forward in pleural disease?
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
The autoclavable semirigid thoracoscope: the way forward in pleural disease?
M. Munavvar, M. A. I. Khan, J. Edwards, Z. Waqaruddin, J. Mills
European Respiratory Journal Mar 2007, 29 (3) 571-574; DOI: 10.1183/09031936.00101706

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
The autoclavable semirigid thoracoscope: the way forward in pleural disease?
M. Munavvar, M. A. I. Khan, J. Edwards, Z. Waqaruddin, J. Mills
European Respiratory Journal Mar 2007, 29 (3) 571-574; DOI: 10.1183/09031936.00101706
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Expiratory flow limitation detected by forced oscillation and negative expiratory pressure
  • Ultrasound-assisted transthoracic biopsy: fine-needle aspiration or cutting-needle biopsy?
Show more Original Articles: Innovative diagnostics

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society