Abstract
To assess the clinical impact of noninvasive mechanical ventilation (NIMV) on stable hypercapnic chronic obstructive pulmonary disease, changes in exercise capacity, dyspnoea and simple physiological parameters were evaluated. The time course of these effects during treatment and recovery was also assessed.
Patients were randomly allocated to NIMV (n = 27) or sham-NIMV (n = 15), applied 3 h·day−1, 5 days a week, for 3 weeks. A 6-min walking distance (6MWD), arterial blood gases, spirometry, pattern of breathing, mouth occlusion pressure (P0.1), and respiratory system impedance (P0.1/tidal volume (VT)/inspiratory time (tI)) were measured weekly during treatment and 2 weekly during follow-up. Transition dyspnoea index (TDI) was also measured.
During NIMV, carbon dioxide arterial tension decreased progressively, concomitantly with a slow deep pattern of breathing, a proportional increase in the forced expiratory volume in one second (FEV1), the forced vital capacity and significant reductions of P0.1 and P0.1/VT/tI. The 6MWD improved by a mean of 76 m after NIMV, and by 73 m and 61 m 1 and 2 weeks, respectively, after treatment. Dyspnoea improved with a mean TDI of three points. Changes in 6MWD were highly related to TDI and to a lesser extent to changes in FEV1 (r = 0.60).
The current authors conclude that noninvasive mechanical ventilation has significant and sustained clinical impact in stable hypercapnic chronic obstructive pulmonary disease.
Noninvasive mechanical ventilation (NIMV) has proven useful in treating patients with severe chronic obstructive pulmonary disease (COPD) and acute respiratory failure (ARS) 1. However, reports on its usefulness in stable COPD are controversial 2. In a previous study, the current authors have shown that intermittent diurnal NIMV reduces hypercapnia and hypoxaemia in patients with severe COPD 3. The mechanisms underlying these changes were a combination of lung deflation, reduction of respiratory loads, and changes in ventilatory pattern. The current findings were in line with a previous uncontrolled study 4. The rationale of this ventilation strategy was primarily based on the hypothesis that high inflation pressure is a key factor for success 5 and that it could be better achieved with closer supervision in the awake patient.
In order to establish if the physiological benefits previously reported with this new ventilatory strategy 3 are accompanied by concomitant and sustained clinical improvements, a randomised placebo-controlled study of weekly NIMV effects on physiology, dyspnoea and exercise capacity in COPD patients with stable hypercapnic respiratory failure was carried out. In addition, residual effects of NIMV during 2 weeks after the end of treatment was also explored.
METHODS
Patients
A total of 62 consecutive patients under chronic care at the Universidad Católica de Chile (Santiago, Chile) outpatient clinic for COPD 6, whose resting daytime carbon dioxide arterial tension (Pa,CO2) was ≥6.65 kPa (50 mmHg), arterial oxygen tension (Pa,O2) <7.98 kPa (60 mmHg), and who were in a clinically and functionally stable state were evaluated. A total of 12 patients were excluded from the study: four with ≥10% increase in per cent predicted forced expiratory volume in 1 s (FEV1) after inhaled salbutamol, three with obstructive sleep apnoeas, two with clinical exacerbations during the preceding 4 weeks, and three with other concomitant disorders (left ventricular failure, peripheral vascular occlusive disease, orthopaedic disorder). Fifty patients agreed to participate in the study, which was approved by the Ethics Committee of Universidad Católica de Chile. A written informed consent was obtained from the patients before enrolment into the study. All patients had stopped smoking for ≥1 yr prior to the study and were on long-term oxygen therapy. None were participating in a respiratory training programme, receiving home mechanical ventilation, nor had previous exposure to NIMV.
Study design
A two-armed single-blinded randomised study of active (NIMV) versus sham-NIMV (s-NIMV) was conducted, with odds of 2:1 to receive NIMV, to add precision to the time-course estimates of mean NIMV effects. Since s-NIMV and NIMV were performed in two separate rooms, patients from different groups were not in contact with each other, and thus remained blinded to the randomisation. Their treating physicians and the nurse supervising dyspnoea and exercise tolerance tests were also blinded to the type of treatment.
Patients first entered a 2-week run-in period, using their current medication, during which they were familiarised with measurements. Spirometry, arterial blood gases and clinical status were assessed at the time of recruitment and at the end of the run-in period. This was followed by a 3-week study period, during which they were randomly allocated to NIMV or s-NIMV using a table of random numbers and sealed envelopes. Ventilation was applied under direct supervision by an experienced, registered nurse at the pulmonary function laboratory, on an outpatient basis. After the study period, patients were followed up for a 2-week period.
NIMV was delivered through a silicone face mask (Hans-Rudolph, Kansas City, MO, USA) and a nonrebreathing valve via a bilevel positive airways pressure (BiPAP) ventilator in spontaneous mode (model S/T-D; Respironics, Inc., Murrysville, Pennsylvania, USA) and s-NIMV via a Siemens Servo ventilator 900C (Siemens; Solna, Sweden) in continuous positive airways pressure (CPAP) mode. Humidifiers were not used. NIMV and s-NIMV were applied for 3 h·day−1, 5 days a week, and during 3 weeks, as previously described 3. In the NIMV group, the level of inspiratory pressure (IPAP) was gradually increased from 8 cmH2O by 2 cmH2O steps during the first hour of ventilation to the highest tolerated level. The latter was considered the target IPAP for that particular patient for the rest of the study. In most cases a gradual increase in pressure to the target IPAP was required at the beginning of each session to maintain the patient's comfort. The mean level of IPAP used was 18±2 cmH2O, whereas the expiratory positive airway pressure was set at a minimum (2 cmH2O). In the s-NIMV group, a low CPAP level of 2 cmH2O was used. The current authors had previously shown that such low levels are not associated with an increase in inspiratory load 3. The protocol allowed administration of supplemental O2 in variable concentrations for both groups in order to maintain an arterial oxygen saturation (Sa,O2) near 94% during the ventilation sessions. Only two patients in the NIMV group needed supplemental oxygen to achieve the target Sa,O2, whereas all controls had to be supplemented with a mean inspiratory oxygen fraction of 0.24±0.03.
Measurements
Measurements were made at baseline, i.e. after the run-in period, and at the end of each week during the treatment period, 24 h post the last session of mechanical ventilation, except for changes in resting dyspnoea which was measured only at the end of the treatment period. Follow-up assessments were performed 7 and 14 days after the end of treatment.
Spirometry and arterial blood gases
Subjects were studied sitting upright in a comfortable chair breathing room air, ∼4 h after inhalation of their usual bronchodilating medications. Spirometry was performed with a calibrated dry spirometer (Vitalograph®; London, UK) according to the American Thoracic Society standards 7. Reference values where those of Knudson et al. 8. Resting daytime arterial blood gases (ABG) were measured with a Ciba Corning 238 gas analyzer (Ciba Corning Diagnostic Corp; Medfield, MA, USA).
Breathing pattern, inspiratory muscle function and central respiratory drive
Airflow was measured with a heated Hans Rudolph pneumotachograph (model 3700A: Raytech Instruments; Vancouver, British Columbia, Canada) and a differential pressure transducer (DP55±3 cmH2O; Raytech Instruments). Volume was obtained by numerical integration of the flow signal. Tidal volume (VT), inspiratory time (tI) and expiratory time (tE), total breath duration and the mean inspiratory flow (VT/tI) were obtained as average values from 1-min flow and volume records. Pressure at airway opening (Pa,o) was measured via a differential pressure transducer (DP55±100 cmH2O; Raytech Instruments). Pressure and flow signals were amplified (AC Bridge amplifier-ACB module; Raytech Instruments) and sampled simultaneously at a rate of 100 Hz by a 16-bit analogue-to-digital converter (Direc Physiologic Recording System, Raytech Instruments). Maximal inspiratory pressure (PI,max) was measured at the mouth starting from functional residual capacity. Mouth occlusion pressure (P0.1) was measured using a one-way valve (Hans-Rudolph, Kansas City, MA, USA) connected to an electrically driven occlusion valve attached to the inspiratory line 9. P0.1 was used to calculate the effective respiratory impedance (P0.1/VT/tI) 10, and a noninvasive tension-time index of inspiratory muscles (TTmus) 11.
Dyspnoea and exercise tolerance
Dyspnoea at baseline was assessed using the Baseline Dyspnoea Index (BDI) 12. Changes in impairment from baseline were measured using the Transition Dyspnoea Index (TDI) 12. The BDI scores ranged from 0–12 points, the higher value corresponding to the lower dyspnoea rating. The TDI scores can vary between -9–9 points, the more positive the change, the greater the improvement. Although recent data indicate than a 1-unit increase in TDI could be clinically meaningful 13, a 2-point increase has probably a lower risk of false positive responses 14. Exercise capacity was assessed by the 6-min walking distance (6MWD) test 15, while patients breathed room air. Dyspnoea exhibited during the walking tests was assessed using the Borg scale 16. A mean increase of 54 m was considered to represent a clinically significant change in 6MWD in COPD patients 17.
Statistical analysis
The results were expressed as mean±sd unless otherwise stated. Baseline values of experimental groups were compared using unpaired t-test. Chi-squared tests were used to evaluate categorical variables. The outcomes were analysed in terms of changes from baseline. Analysis of covariance (ANCOVA) was used to estimate differences in change between the experimental and sham group, with baseline values as the covariate along with group allocation 18. Two-way analysis of variance for repeated measurements was applied to weekly changes from baseline to examine the interaction between time and treatment. In case of significant treatment–time interaction, i.e. differences between groups across time, post hoc analyses for between-group comparisons were carried out with unpaired t-tests at each time point. The relationships between variables were analysed using Pearson (r) and Spearman rank (rho) correlations. Statistical significance was defined as a two-tailed p<0.05.
RESULTS
Run-in period and baseline measurements
From the 50 patients enrolled in the study, eight who showed a spontaneous reduction in Pa,CO2≥0.399 kPa (3 mmHg) or to a value <6.65 kPa (50 mmHg) at the end of the run-in period were excluded. Among the 42 randomised patients, mean changes in FEV1 and Pa,CO2 during the run-in period (5 mL and −0.0532 kPa (−0.4 mmHg)) were not significant. General baseline characteristics measured at the end of the run-in period, and the respiratory medication of the 27 treated and 15 control subjects are shown in table 1⇓. Baseline and final (end-of-treatment) physiological and clinical variables are displayed in table 2⇓.
Physiological effects of noninvasive mechanical ventilation
There were no significant differences between groups in baseline values. None of the parameters varied significantly after s-NIMV. During NIMV, Pa,CO2 significantly decreased along with a slow and deep pattern of breathing. Pa,O2 increased in proportion to Pa,CO2 decrease. FEV1 and forced vital capacity (FVC) increased proportionally, and consequently the FEV1/FVC ratio remained constant. Effective respiratory impedance (P0.1/VT/tI) and inspiratory muscle loads, as reflected by TTmus, were decreased at the end of treatment. A small but significant increase in PI,max was also found.
All patients, except two in the control group, had severe hypoxaemia (Pa,O2<7.315 kPa; 55 mmHg) at baseline. After NIMV, 12 patients increased their Pa,O2≥7.315 kPa (55 mmHg), while the proportion of patients with severe hypoxaemia was unchanged after s-NIMV.
Clinical effects of NIMV
The 6MWD increased significantly in NIMV patients, with an average gain of 76 m, along with a significant decrease in dyspnoea (Borg scale) at the end of the walking test (table 2⇑). Figure 1⇓ shows individual values for 6MWD changes and TDI in the left panel. An increase in 6MWD ≥54 m was observed in 19 of the 27 NIMV patients, whereas none of the control subjects reached this clinically significant level of improvement. The TDI at the end of treatment was also significantly higher in NIMV patients compared with the sham group (3.1±1.2 versus 0.07±0.7 points, respectively; p<0.0001), indicative of a decrease in dyspnoea. An increase of a minimum one point was found in all subjects and of at least two points in 23 of the 27 treated subjects. Such a level of improvement was not found in subjects from the control group. A close association between changes in 6MWD and TDI was found in the entire group, as shown in the left panel (rho = 0.90; p<0.0001) and with changes in FEV1, as shown in the right panel (r = 0.60; p<0.0001). Variations of the other physiological parameters were not associated with significant changes in 6MWD. By contrast, TDI was closely related to ΔP0.1/VT/tI (rho = −0.73), ΔPa,CO2 (rho = −0.71), ΔP0.1 (rho = −0.66), ΔfR (rho = −0.64), ΔTTmus (rho = −0.61), ΔFVC (rho = 0.58), and ΔFEV1 (rho = 0.55; p<0.0001 in all cases).
Time course of noninvasive mechanical ventilation effects
Weekly evolution during treatment and the following 2 weeks is shown in figures 2⇓ and 3⇓. Figure 2⇓ shows the pattern of breathing, arterial blood gases, and spirometry while figure 3⇓ includes respiratory mechanics and exercise capacity. All physiological variables started to exhibit significant changes from the end of the first week of treatment, except PI,max and TTmus, which achieved significant changes later. These effects were progressive and maximal by the end of the third week. Clinical improvements in terms of exercise capacity mirrored those physiological changes. All these changes appeared to gradually fade away from the first week after treatment although most were still significant 2 weeks after cessation. At this point, 94% of the gain in PI,max and 82% of the gain in 6MWD were maintained, in contrast to only 31% for FEV1, 42% for VT and 52% for P0.1/VT/tI.
DISCUSSION
The main findings of the present study include: 1) Diurnal short-term intermittent NIMV in stable hypercapnic COPD patients results in clinical improvement, reducing dyspnoea and enhancing exercise capacity in addition to improvement in ABG, breathing pattern and respiratory mechanics. 2) All of the physiological effects are significant within the first week of treatment, except for unloading of the inspiratory muscles which becomes significant only after 2 weeks.
Physiologial effects of noninvasive mechanical ventilation
Improvements in Pa,CO2 have been previously reported after short-term application of NIMV using either negative or positive pressure ventilation. Ambrosino et al. 19 reported a reduction of Pa,CO2 after only two sessions of NIMV. A slow and deep pattern of breathing has been reported by Scano et al. 20 after 7 days of ventilation and after 4 weeks by others 21, 22. Interestingly, Gigliotti et al. 21 measured the sequence of changes in Pa,CO2 and VT after 13 and 27 days of ventilation and found that improvement was progressive. All of the above studies have concluded that beneficial effects of NIMV can be attributed to the improvement in inspiratory muscle function, particularly because the rest achieved during ventilation sessions could alleviate a possible “chronic fatigue” of the inspiratory muscles. Clearly, the present study does not support this hypothesis, since the baseline TTmus values were found to be approximately half the critical level associated with inspiratory muscle fatigue 11. In addition, PI,max increased significantly only at the end of the treatment period, after all other changes had taken place.
Why did these patients reduce Pa,CO2 so quickly after NIMV? The current authors have previously shown that tidal volume was markedly increased during NIMV sessions 3, and the present study shows that a deep and slow pattern of breathing is maintained by the patients between sessions. Such pattern of breathing has been shown to reduce Pa,CO2 in hypercapnic COPD patients but it has been reported that it markedly increases the work of breathing and induces fatigue 23. TTmus analysis shows that this was not the case in the patients in the present study, the current authors suggest that the effect may be explained by the observed lower effective respiratory impedance. Indeed, the patients could not only achieve higher levels of alveolar ventilation with no additional energetic cost during the first week of treatment, but they actually decreased their TTmus when effective respiratory impedance further improved. The current authors previously demonstrated that lung volume deflation was a key factor to explain these benefits 3, as also shown with the use of long-acting bronchodilators 24, 25. The effect of NIMV on spirometric lung volumes, dyspnoea, and exercise tolerance cannot be attributed to the use of bronchodilators, since the latter was similarly used in the two groups. However, NIMV clearly provides further benefits to patients on appropriate bronchodilation therapy.
Clinical effects of noninvasive mechanical ventilation
In the present study, the authors were particularly interested in the clinical effects of NIMV. Therefore, the increase in 6MWD was impressive as it had only been previously reported in uncontrolled trials 19, 21, 26. Renston et al. 27 found an increase in the 6MWD after 5 days of ventilation. Improvements in exercise capacity were also reported in other short- 19, 21 and long-term studies 26. In contrast, randomised controlled trials have failed to show a significant improvement in the 6MWD 5, 28–31. There are several possible reasons to explain the discrepancy. First, in most of the previous studies the amount of inspiratory pressure was lower than that employed in the present study, being similar only in the study of Meecham Jones et al. 5. It has been shown that high inspiratory pressures can modify the breathing pattern, increasing VT and tE 3, 32, providing room to reduce Pa,CO2 and decrease lung hyperinflation. The current authors found in this and in a previous study 3 that progressive increase to high inspiratory pressures is possible with daytime supervision. It should be noted that supervision of the procedure is limited when NIMV is applied at home, and consequently compliance is reduced because of mask leaks, asynchrony between the patient and ventilator, and discomfort 33. Finally, as pointed out by Wijkstra et al. 34 the high upper limit of the confidence interval for the 6MWD (82 m) found in the randomised controlled trials suggests that at least some patients might improve their exercise capacity after NIMV. The present data are in agreement with the hypothesis, as only 70% of the patients submitted to NIMV (figure 1⇑) increased the 6MWD≥54 m. It is noteworthy that the improvement in the 6MWD after the 2 week follow-up was maintained to a greater extent than any of the physiological changes. A possible explanation for this finding is that these patients could have increased their daily physical activities during the treatment period, achieving some degree of general training.
It is also of interest that some reduction in dyspnoea was found in all treated subjects and that this change was a far better predictor of exercise capacity than any single physiological parameter. Improvement in dyspnoea after NIMV had been reported in two randomised controlled trials 30, 31. However, these studies did not suggest a mechanism for the alleviation of dyspnoea. The current data shows that it is related to a reduction in inspiratory loads (decrease in P0.1/VT/tI and TTmus), and to a slower breathing rate which promotes lung deflation.
An unexpected finding was the high proportion of treated patients (12 out of 27) that increased their Pa,O2 >7.315 kPa (55 mmHg) by the end of treatment. It can be speculated that some of these patients may no longer need long-term O2 therapy, resulting in a significant gain in quality of life.
Clinical implications
NIMV may be an effective component of pulmonary rehabilitation in severe hypercapnic COPD patients. However, the best schedule to deliver NIMV in this condition is not yet known. In the present study, NIMV was applied at the hospital during the day in outpatients in order to achieve adequate supervision of the procedure. Diurnal application of NIMV is not widely accepted, the common practice being to apply it at home overnight during sleep 5, 28–31. The main reason for night time application comes from studies which demonstrate that benefits obtained with NIMV are related to an improvement in sleep-related hypoventilation and sleep architecture 5, 35. However, in a group of patients with extra pulmonary restrictive disease, Schonhofer et al. 36 showed that NIMV was equally effective in improving sleep characteristics when administered during the day or overnight. Furthermore, there is no study comparing the efficacy of home versus hospital application of NIMV or addressing the importance of supervision. The present study provides evidence supporting its daytime use, in line with previous studies in which negative pressure ventilators were employed 18–20, 26, 37. Daytime use of short term NIMV in the hospital setting allowed a closer supervision of treatment and insured patient compliance. Although patient compliance with this protocol, in the long term, is not known and widespread use may result in significant hospital burden, the present study suggests that an active supervision of treatment, at least in the first weeks after initiating NIMV, is a major factor for success. The current data also suggest that NIMV need not be applied as frequently, as residual effects were found up to 2 weeks after the end of treatment. Residual effects of NIMV have been previously reported by Fernandez et al. 37 and could also help to explain the results of Gutiérrez et al. 26 who have found that applying NIMV once a week provides benefits to hypercapnic COPD patients. A less frequent daytime application might prove useful and improve adherence to NIMV, reducing the high dropout rate found in some previous studies 28, 29.
To summarise from a clinical standpoint, the present study supports daytime use of noninvasive mechanical ventilation, as previously shown with negative pressure ventilators. It also suggests that noninvasive mechanical ventilation does not have to be applied on a daily basis, since residual physiological effects and improvement in exercise capacity were found up to 2 weeks after cessation. Both diurnal and intermittent application of noninvasive mechanical ventilation could make this treatment more tolerable for patients, with fewer dropout rates.
- Received March 22, 2005.
- Accepted August 11, 2005.
- © ERS Journals Ltd