Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions

Duration of effect of single-dose inhaled fluticasone propionate on AMP‐induced bronchoconstriction

B. Luijk, R.D. Kempsford, A.M. Wright, P. Zanen, J-W.J. Lammers
European Respiratory Journal 2004 23: 559-564; DOI: 10.1183/09031936.04.00043504
B. Luijk
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R.D. Kempsford
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A.M. Wright
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P. Zanen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J-W.J. Lammers
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Airway hyperresponsiveness induced by adenosine‐5'‐monophosphate (AMP) is regarded as a reliable model for allergic asthma and for the evaluation of anti-asthmatic drugs. Single-dose inhaled corticosteroids (ICS) are known to be protective in this model, but the duration of action of these drugs in this model has never been studied.

The duration of ICS protection was determined by administration of single-dose fluticasone propionate (FP; 1,000 µg) up to 26 h before AMP challenge. A randomised, double-blind, placebo-controlled, four-way crossover study was performed in 13 mild asthmatics (mean±sd predicted forced expiratory volume in one second (FEV1) 98±7%). Each subject received placebo and FP (at 26, 14 or 2 h prior to the AMP challenge). Furthermore, the marker exhaled nitric oxide (eNO) was studied after administration at these time points to investigate whether eNO also demonstrates the duration of action of ICS.

The doubling concentrations difference (DCD) of AMP causing a 20% fall in FEV1, when FP was administered 26, 14 or 2 h prior to challenge, was significantly increased as compared with placebo: DCD (95% confidence interval) at 26 h, 0.73 (0.20–1.26), p=0.008; 14 h, 1.50 (0.99–2.01), p<0.001; and 2 h, 2.89 (2.37–3.40), p<0.001. However, eNO was not significantly affected at these time points.

In conclusion, a single dose of 1,000 µg inhaled fluticasone propionate protects against adenosine‐5'‐monophosphate airway hyperresponsiveness up to 26 h after dosing. This study suggests that adenosine‐5'‐monophosphate challenge can be used as a sensitive marker to study the duration of action of inhaled corticosteroids.

  • adenosine‐5'‐monophosphate
  • airway hyperresponsiveness
  • asthma
  • exhaled nitric oxide
  • fluticasone propionate

This study was funded by GlaxoSmithKline, UK.

Inhaled corticosteroids (ICS) are commonly used as protective anti-inflammatory drugs in the treatment of asthma 1. The anti-inflammatory effects of ICS can be shown by demonstrating their influence on airway hyperresponsiveness (AHR), which is one of the characteristics of chronic airway inflammation in asthma 2.

AHR can be measured using inhalation of direct bronchoconstrictors (e.g. histamine or methacholine) or indirect agents such as adenosine‐5'‐monophosphate (AMP) 3. Inhaled AMP functions, at least in part, through activation of mast cells that release the secondary bronchoconstricting mediators leukotrienes and histamine 4, 5. These indirect airway challenges appear to be a better surrogate marker of the ICS‐induced anti-inflammatory effects than direct challenges 3, 6, 7.

Recently, two studies demonstrated a rapidly induced protective effect when a single dose of an ICS was administered prior to an indirect challenge. A protective effect of fluticasone propionate (FP) against AMP challenge was observed within 2 h of administration and a protective effect of budesonide against hypertonic saline challenge was found within 6 h of administration 8, 9. Interestingly, the study with single-dose inhaled FP demonstrated protection towards AMP‐AHR but not after direct challenge with histamine. Therefore, AMP‐induced bronchoconstriction appears to be a rapid model to evaluate the anti-inflammatory effect, the direct potency and thus efficacy of single-dose ICS in asthmatics.

However, currently no information exists on the duration of effect of a single inhaled dose of FP on AHR. This duration of effect could then be used in comparative studies with other ICS.

Furthermore, the current authors were interested in whether the AMP challenge is solely affected by a single dose of ICS or whether another surrogate marker of airway inflammation is as sensitive as AMP‐AHR to show this rapid anti-inflammatory response. This was the rationale for studying eNO, which has also been shown to be a sensitive marker of ICS‐induced anti-inflammatory effects 10.

Therefore, the aim of this study was to investigate the duration of effect of a single dose of inhaled FP by using the AMP‐challenge model and to compare AMP‐AHR with eNO as surrogate markers of airway inflammation. A relatively high optimal dose of 1,000 µg FP, as indicated by the results of Ketchell et al. 8, was studied to determine the duration of protection after a single dose of FP.

Materials and methods

Subjects

Thirteen nonsmoking, atopic subjects with intermittent or mild persistent asthma, according to the GINA (Global Initiative on Asthma) guidelines 11, were included in the study. Presence of atopy was confirmed by at least one positive skin-prick test. At screening and during treatment periods, all subjects' asthma was stable and demonstrated a provocation concentration of AMP causing a 20% fall in forced expiratory volume in one second (FEV1) (AMP‐PC20) of <50 mg·mL−1 at screening. After a run-in period of 7 days, a second AMP challenge was performed to confirm stability of the AMP‐PC20. If the AMP‐PC20 was not within 1.5 doubling concentrations from the screening value the subject was excluded from further participation in the study. Every patient had a baseline FEV1 of >70% predicted according to European Respiratory Society values 12. ICS and other anti-asthmatic medications were not allowed 4 weeks before the screening visit and throughout the study, except for short-acting β2‐agonists, which had to be withheld 12 h before each visit. Subjects who used oral corticosteroids within 8 weeks before entering the study and throughout the study were also excluded. Caffeine-containing food and beverages and alcohol were not allowed 8 h before and during each treatment period.

The study was approved by the medical ethics committee of the University Medical Center Utrecht (Utrecht, the Netherlands) and all patients gave their written informed consent.

Study design

All subjects underwent four treatment periods according to a randomised, double-blind, crossover, placebo-controlled design. The duration and efficacy of a single-dose ICS was determined by administration of 1,000 µg FP from a four blister diskhaler device (GlaxoSmithKline, Stevenage, UK) in each treatment period. There were four, 2‐day treatment periods. Each subject received four different treatments: three active (FP) and one with placebo only. For the active treatments, single-dose FP 1,000 µg was administered 26, 14 or 2 h prior to AMP challenge. For each active treatment period, matching placebo (lactose powder) was administered at the other time points to maintain the treatment blinding. The placebo-alone treatment was lactose powder at 26, 14 and 2 h pre‐AMP challenge. There was a washout period of at least 1 week between each treatment. During the study, only salbutamol was permitted to inhale as rescue medication if needed. Seven to 14 days after the final treatment period, subjects returned to the hospital for a post-study final visit for safety blood tests and to establish stable asthmatic symptoms.

AMP challenge

AMP was inhaled in doubling concentrations at 5‐min intervals in the range 0.04–320 mg·mL−1, according to a standardised challenge protocol to determine AMP‐PC20 as previously described 13, 14. FEV1 was measured in duplicate at 30 and 90 s after 2‐min tidal breathing from a calibrated (0.13 mL·min−1) nebuliser (model 646; Devilbiss Inc., Somerset, PA, USA) while the nose was clipped. During the double-blind period, inhaled AMP was given until the FEV1 fell by ≥20% from baseline or when the maximum concentration of AMP was inhaled. AMP (Sigma-Aldrich, St. Louis, MO, USA) was dissolved in saline (0.9%) solution to produce the doubling concentrations.

Forced expiratory volume in one second measurements

FEV1 measurements were recorded with the same mobile bi-directional digital spirometer (Sensorloop; SensorMedics Corp, Yorba Linda, CA, USA) during treatment periods at pre-dose at day 1 (i.e. before the first of the three doses) and pre-dose at day 2 (i.e. before the last of the three doses, FEV1 only), pre-challenge (i.e. 2 h after the last administered dose), and regular time points during AMP‐challenge protocol.

Exhaled nitric oxide

Exhaled nitric oxide (eNO) was measured in parts per billion, according to the American Thoracic Society standards, with a calibrated chemiluminescence analyser (type CLD 77 AM; Eco Physics, Duernten, Switzerland) with a flow rate of 250 mL·s−1 15. Exhalations into a NO reader were repeated three times and then the overall mean was calculated. eNO was measured at similar time points to FEV1, except the pre-dose value at day 2. The eNO recordings were always obtained before the FEV1 values.

Measurement of plasma fluticasone propionate levels

Blood samples were taken for determination of plasma FP concentrations to demonstrate the absence of circulating FP prior to dosing and to determine the plasma FP concentrations at AMP challenge. Blood samples (5 mL) were collected before the first dose and immediately pre‐AMP challenge (2 h after the last dose was inhaled), and placed immediately on ice and centrifuged at 1,000×g for 10 min at 4°C. The plasma supernatant was stored in tubes at −70°C until further processing. FP was then quantified in plasma by automated solid-phase extraction followed by liquid chromatography tandem mass spectrometry (Applied Biosystems API3000; Applied Biosystems, Warrington, UK). The limit of quantification was 10 pg·mL−1.

Data analysis

The planned sample size of 12 subjects was predicted to have 80% power to detect a ratio for AMP‐PC20 of 2.4 between any two of the treatment groups, assuming a within-subject sd on the loge scale of 0.77 and a significance level of 5%. This ratio is equivalent to a difference of 1.26 doubling concentrations difference (DCD) between treatment groups. The AMP‐PC20 and eNO measurements were analysed using analysis of variance. The following factors were included in the models: subject, period and treatment group. The data were log transformed prior to analyses. For the PC20 data, differences and 95% confidence intervals (CI) between treatment groups were presented in terms of DCDs. For the NO data, the comparisons were calculated in terms of a ratio (eNO ratio) and 95% CI (FP/placebo). A ratio of 1 would indicate no effect of FP compared with placebo. All other data were expressed as (geometric) means (95% CI) unless otherwise stated. Differences were considered to be statistically significant if the p‐level was <0.05.

Results

Subjects

Subject characteristics are listed in table 1⇓. The AMP‐AHR of the included subjects was stable before starting the four treatment periods (individual AMP‐PC20 values were within the above-mentioned 1.5 DCD). The mean AMP‐PC20 difference between screening and run-in period expressed in DCD±sd was 0.27±0.71.

View this table:
  • View inline
  • View popup
Table 1—

Subject characteristics of included mild asthmatic patients

Due to incorrect diskhaler use, one subject received the same treatment twice (FP 14 h before the challenge). Although this subject completed the trial, an additional subject was recruited. Data from all 13 subjects were used in the analyses.

Effect of single-dose inhaled fluticasone propionate on forced expiratory volume in one second

During the four treatment periods with either active FP at the three different FP administration time points or the placebo treatment, no differences were found in pre-dose and post-dose FEV1 values (FP at 26 h: 3.88 L (3.40–4.43); FP at 14 h: 3.93 L (3.47–4.44); FP at 2 h: 3.83 L (3.38–4.34); and during placebo: 3.76 L (3.32–4.27)). Furthermore, no differences in baseline FEV1 values were observed between the four treatment periods during the study.

Effect of single-dose inhaled fluticasone propionate on AMP‐PC20

The individual AMP‐PC20 data are given in table 2⇓. The AMP‐PC20 after FP administration was statistically significantly different from placebo treatment at all three time points. The DCD (95% CI; FP to placebo) were as follows: 0.73 (0.20–1.26), p=0.008; 1.50 (0.99–2.01), p<0.001; and 2.89 (2.37–3.40), p<0.001, for the 26 h, 14 h and 2 h groups, respectively, as shown in figure 1a⇓ and table 3⇓. The AMP‐PC20 measured at 2 h after FP inhalation was also significantly higher than the AMP‐PC20 values at 26 and 14 h, respectively (DCD 2–26 h: 2.16 (1.63–2.68), p<0.001; 2–14 h: 1.39 (0.88–1.89), p<0.001), and a significant difference between 26 and 14 h time points of FP administration (DCD: 0.77 (0.24–1.30), p=0.005) was observed. Although there is one clear upper outlier in the AMP‐PC20 dataset at 26 h FP administration, this outlier did not have a large influence on the results. An analysis was performed excluding this subject and the difference at 26 h was still statistically significant.

Fig. 1.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.—

a) Doubling concentrations difference (DCD) and 95% confidence intervals (CI) of the provocative concentration of AMP causing a 20% fall in the forced expiratory volume in one second (AMP‐PC20) with the administered active fluticasone propionate (FP) treatment compared with placebo at the indicated time points. b) Ratio and 95% CI of exhaled nitric oxide (eNO) with the administered active FP treatment compared with placebo at the indicated time points.

View this table:
  • View inline
  • View popup
Table 2—

The individual provocation concentration of AMP causing a 20% fall in forced expiratory volume in one second values during the four treatment periods (placebo, 26, 14 and 2 h) in 13 asthmatics

View this table:
  • View inline
  • View popup
Table 3—

Geometric means and doubling concentration differences (DCD) of the provocation concentration of AMP causing a 20% fall in forced expiratory volume in one second (AMP‐PC20) values during placebo and fluticasone propionate (FP) administered 26, 14 and 2 h before AMP challenge

The effect of single-dose fluticasone propionate on exhaled nitric oxide

In table 4⇓, the geometric means and ratios for the eNO values for the four treatment groups are presented. There was a nonsignificant decrease in pre-challenge eNO values when FP was administered 26 and 14 h prior to the AMP challenge, with a lowest ratio of 0.83 (0.68–1.01, p=0.06) at 26 h FP administration compared to placebo (table 4⇓ and fig. 1b⇑).

View this table:
  • View inline
  • View popup
Table 4—

Geometric means and ratio of the pre-challenge exhaled nitric oxide (eNO) concentrations during placebo and fluticasone propionate (FP) administered 26, 14 and 2 h before AMP challenge

Plasma fluticasone propionate levels

Pre-challenge plasma FP concentrations were below the limit of quantification in the placebo treatment period and in all the pre-treatment samples. Plasma FP levels immediately prior to AMP challenge (i.e. 2 h post-dose) were detectable in all subjects when FP was given 14 h (median 32.8 pg·mL−1 (range 16.8‐57.4)) and 2 h (147.1 pg·mL−1 (65.8‐225.0)) before the AMP challenge. When FP was administered 26 h prior to the AMP challenge, plasma FP levels were below the limit of quantification in half the subjects, whereas the other subjects demonstrated a median of 15.3 pg·mL−1 (10.2–20.7). There was no correlation between DCD AMP‐PC20 improvement and the 2‐h post-dose plasma FP levels at the time points studied.

Discussion

In this study, the authors found that a single dose of 1,000 µg inhaled FP, administered 26, 14 or 2 h prior to challenge, protected against AMP‐induced bronchoconstriction. A single dose of 1,000 µg FP given at these time points did not appear to significantly change pre‐AMP challenge FEV1 or eNO levels.

The findings of AMP‐PC20 improvement are in agreement with previous studies demonstrating similar improvement after repeat-dose or single-dose inhalation of ICS when the last dose was administered shortly before challenge 8, 9, 16, 17. This early protective effect of FP against AMP challenge is also consistent with the recent findings of Prosperini et al. 7, who showed that AHR to inhaled AMP promptly detected inflammatory changes of the asthmatic airways as early as the first week of treatment with budesonide and that AMP‐PC20 returned to near baseline levels as early as the first week of treatment 7. In addition, a single dose of ICS administered just before an allergen challenge inhibited the late asthmatic response 18. In the present study, the duration of anti-inflammatory effects of single-dose FP was directly assessed by altering the FP‐AMP challenge interval.

ICS are known for their topical anti-inflammatory effects and inhaled FP in particular has a highly favourable topical efficacy compared with systemic safety 19. This direct topical effect of ICS is supposed to be responsible for the acute clinical effect on FEV1 as soon as 2 h, as demonstrated in a previous study in acute severe asthma 20. This FEV1 improvement was also shown 6 h after single high-dose ICS treatment with budesonide (2,400 and 1,600 µg, respectively) 9, 21. However, no effect was found on the FEV1 2 h after administration of a single dose of 1,000 µg FP in the study by Ketchell et al. 8, which is comparable to the present results at 2 h, or at the 14 and 26 h time points. This may be due to the current mild stable disease of the asthmatics that were studied. Moreover, ICS induce an acute anti-inflammatory effect on AHR measured by indirect challenges 8, 9. The improvement on AMP‐AHR after FP inhalation up to 26 h found in this study may be due to local high affinity towards the glucocorticoid receptor of FP in the airways after inhalation and by the long half-life of the FP active steroid receptor complex of >10 h 22, 23. The optimal FP protection on AMP‐induced bronchoconstriction was demonstrated in a recent abstract, with the highest effect when FP was administered 4 h prior to an AMP challenge and not at the previously mentioned 2 h 24. In addition, the decreasing anti-inflammatory response measured by AMP‐AHR up to 26 h was associated with nondetectable FP plasma levels in half of the subjects and, without correlation, with the doubling concentration of the AMP‐PC20 difference at the three time points, which further supports the notion that this duration of action is a sustained topical FP effect rather than a systemic anti-inflammatory effect 19.

Recently, several mechanisms have been proposed regarding the acute protective effect of single-dose ICS on AMP‐induced bronchoconstriction by influencing the adenosine receptors that may play a role in airway inflammation 8. The inhibition of adenosine receptor activity by ICS after binding to the glucocorticoid receptor on the membrane is suggested to be rapidly induced by nongenomic anti-inflammatory effects within minutes and by genomic anti-inflammatory effects within hours 8, 25. It is likely that both the nongenomic and genomic effects interact with the adenosine receptor activity intracellularly or via a direct interaction at the adenosine receptor site. This may cause the improvement on AMP‐AHR up to 26 h, with an effect that decreases in time, as found for the decrease of protection from 2 to 14 h, and up to 26 h in this study. Furthermore, adenosine induces plasma exudation and bronchial blood flow increase that are associated with the local vascular effects of microvascular leakage and oedema of the airway wall that have been described as factors of AHR 2, 26. These vascular events may be reduced by ICS, with FP, in particular, being a potent agent to induce a vasoconstrictive effect 22, 25. In addition, it has previously been stated that FP decreases microvascular leakage and airway mucosal blood flow 2, 27. These effects together may contribute to the prolonged protection by FP up to 26 h on AMP‐induced bronchoconstriction in the present study. However, the exact mechanisms behind this duration of effect of acute ICS‐induced inhibition on AMP‐AHR needs further study.

This study may have some limitations. First, the dose-response for the activity of FP administered up to 26 h prior to AMP challenge was not determined in this study and therefore it is still unclear whether lower FP doses may cause similar improvement in AMP‐PC20. However, a recently published study demonstrated a dose-dependent effect after 2 h, using FP at either 100, 250 or 1,000 µg 8. Thus, the protection by inhaled FP appears to be a topical effect rather than an effect due to systemic exposure and hence lower doses might also be effective 14 and 26 h after inhalation. Secondly, only FP was studied. Other types of ICS could have been used to demonstrate the same duration of effect. Although protection on AMP‐induced bronchoconstriction has been shown when single doses of beclomethasone 2,000 µg or budesonide 1,600 µg were administered 2 h prior to AMP challenge, this may not have similar results when studying duration of action in this model 28. Thirdly, these single-dose effects of ICS towards AMP challenge may be influenced by the increasing osmolarity of the inhaled doubling concentrations of solutions, which has been shown to have an affect on the AHR in asthmatics 29. Finally, the present study shows a model to assess the duration of effect of ICS for comparative studies on newly developed types of ICS, not for the purpose of dose regimen for clinical beneficial effects of a prolonged protection by a single dose of 1,000 µg of FP. Despite the significant anti-inflammatory effect up to 26 h after FP administration, this model cannot be directly extrapolated to the clinical situation where ICS are given on a long-term basis.

In contrast to AMP challenge, the absence of a protective effect of FP on eNO up to 26 h after FP administration may indicate that these tests reflect different aspects of airway inflammation. Whether an ICS‐induced anti-inflammatory effect on eNO release is dose-dependent, type of ICS dependent, time dependent or due to the mild disease of the included asthmatics has to be studied further. In addition, there is some evidence that it is dose dependent, as after 6 h, single high-dose ICS treatment with nebulised budesonide (8 mg), the eNO levels were reduced 10. Furthermore, the percentage of sputum eosinophils may also be used to show an ICS‐induced anti-inflammatory response, which was decreased 6 h after a single dose of budesonide 9. These markers are all sensitive after hours of ICS treatment, whereas direct challenges are not 8. These inflammatory markers and FEV1 appear to be less sensitive to reflect the direct activities of ICS‐induced anti-inflammatory effects, as has been shown for AMP‐AHR, which showed a directly proportional effect to the dose or timing of inhaled ICS used. Thus, taken together, these findings strengthen the view that AMP challenge is exceptionally sensitive to the topical effects of ICS.

In conclusion, a single dose of 1,000 µg inhaled fluticasone propionate demonstrated a duration of action of up to 26 h by protection against adenosine‐5'‐monophosphate-induced bronchoconstriction, without a significant effect on exhaled nitric oxide. This study further suggests that the anti-inflammatory response measured by an adenosine‐5'‐monophosphate challenge is a sensitive tool for future comparative studies on duration of action of newly developed inhaled corticosteroids.

  • Received April 17, 2003.
  • Accepted November 24, 2003.
  • © ERS Journals Ltd

References

  1. ↵
    Lipworth BJ. Fortnightly review: modern drug treatment of chronic asthma. BMJ 1999;318:380–384.
    OpenUrlFREE Full Text
  2. ↵
    Barnes PJ. Effect of corticosteroids on airway hyperresponsiveness. Am Rev Resp Dis 1990;141:S70–S76.
    OpenUrlPubMedWeb of Science
  3. ↵
    Joos GF, O'Connor B, Anderson SD, et al. Indirect airway challenges. Eur Respir J 2003;21:1050–1068.
    OpenUrlAbstract/FREE Full Text
  4. ↵
    Polosa R. Adenosine-receptor subtypes: their relevance to adenosine-mediated responses in asthma and chronic obstructive pulmonary disease. Eur Respir J 2002;20:488–496.
    OpenUrlAbstract/FREE Full Text
  5. ↵
    Van Schoor J, Joos GF, Pauwels RA. Indirect bronchial hyperresponsiveness in asthma: mechanisms, pharmacology and implications for clinical research. Eur Respir J 2000;16:514–533.
    OpenUrlAbstract/FREE Full Text
  6. ↵
    Van den Berge M, Meijer RJ, Kerstjens HA, et al. PC(20) adenosine 5'‐monophosphate is more closely associated with airway inflammation in asthma than PC(20) methacholine. Am J Respir Crit Care Med 2001;163:1546–1550.
    OpenUrlPubMedWeb of Science
  7. ↵
    Prosperini G, Rajakulasingam K, Cacciola RR, et al. Changes in sputum counts and airway hyperresponsiveness after budesonide: monitoring anti-inflammatory response on the basis of surrogate markers of airway inflammation. J Allergy Clin Immunol 2002;110:855–861.
    OpenUrlCrossRefPubMedWeb of Science
  8. ↵
    Ketchell RI, Jensen MW, Lumley P, Wright AM, Allenby MI, O'Connor BJ. Rapid effect of inhaled fluticasone propionate on airway responsiveness to adenosine 5'‐monophosphate in mild asthma. J Allergy Clin Immunol 2002;110:603–606.
    OpenUrlCrossRefPubMedWeb of Science
  9. ↵
    Gibson PG, Saltos N, Fakes K. Acute anti-inflammatory effects of inhaled budesonide in asthma: a randomized controlled trial. Am J Respir Crit Care Med 2001;163:32–36.
    OpenUrlCrossRefPubMedWeb of Science
  10. ↵
    Kharitonov SA, Barnes PJ. Clinical aspects of exhaled nitric oxide. Eur Respir J 2000;16:781–792.
    OpenUrlAbstract
  11. ↵
    NHLBI/WHO Workshop Report 1995. Global strategy for asthma management and prevention. National Institutes of Health. National Heart, Lung, and Blood Institute, Bethesda, MD, updated April, 2002. Publication No. 95-3659. (Scientific information and recommendations for asthma programs. NIH Publication No. 02-3659).
  12. ↵
    Roca J, Burgos F, Sunyer J, et al. References values for forced spirometry. Group of the European Community Respiratory Health Survey. Eur Respir J 1998;11:1354–1362.
    OpenUrlAbstract
  13. ↵
    Sterk PJ, Fabbri LM, Quanjer PhH, et al. Standardized challenge testing with pharmacological, physical and sensitizing stimuli in adults. Eur Respir J 1993;6:; Suppl 16, 53–83.
    OpenUrlAbstract/FREE Full Text
  14. ↵
    Oosterhof Y, Koeter GH, De Monchy JGR, Postma DS. Circadian variation in airway responsiveness to metacholine, propranolol, and AMP in atopic asthmatic subjects. Am Rev Resp Dis 1993;147:512–517.
    OpenUrlPubMedWeb of Science
  15. ↵
    American Thoracic Society. Recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide in adults and children‐1999. Am J Respir Crit Care Med 1999;160:2104–2117.
    OpenUrlCrossRefPubMedWeb of Science
  16. ↵
    O'Connor BJ, Ridge SM, Barnes PJ, Fuller RW. Greater effect of inhaled budenoside on adenosine 5'‐monophosphate-induced than on sodium-metabisulfite-induced bronchoconstriction in asthma. Am Rev Resp Dis 1992;146:560–564.
    OpenUrlPubMedWeb of Science
  17. ↵
    Van den Berge M, Kerstjens HA, Meijer RJ, et al. Corticosteroid-induced improvement in the PC20 of adenosine monophosphate is more closely associated with reduction in airway inflammation than improvement in the PC20 of methacholine. Am J Respir Crit Care Med 2001;164:1127–1132.
    OpenUrlCrossRefPubMedWeb of Science
  18. ↵
    Kidney JC, Boulet L‐P, Hargreave FE, Deschesnes F, Swystun VA, O'Byrne PM. Evaluation of single-dose inhaled corticosteroid activity with an allergen challenge model. J Allergy Clin Immunol 1997;100:65–70.
    OpenUrlCrossRefPubMed
  19. ↵
    Lawrence M, Wolfe J, Webb DR, et al. Efficacy of inhaled fluticasone propionate in asthma results from topical and not from systemic activity. Am J Respir Crit Care Med 1997;156:744–751.
    OpenUrlPubMedWeb of Science
  20. ↵
    Rodrigo G, Rodrigo C. Inhaled flunisolide for acute severe asthma. Am J Respir Crit Care Med 1998;157:698–703.
    OpenUrlPubMedWeb of Science
  21. ↵
    Engel T, Dirksen A, Heinig JH, Nielsen NH, Weeke B, Johansson SA. Single-dose inhaled budesonide in subjects with chronic asthma. Allergy 1991;46:547–553.
    OpenUrlPubMedWeb of Science
  22. ↵
    Johnson M. Development of fluticasone propionate and comparison with other inhaled corticosteroids. J Allergy Clin Immunol 1998;101:S434–S439.
    OpenUrlCrossRefPubMedWeb of Science
  23. ↵
    Derendorf H, Hochhaus G, Meibohm B, Mollmann H, Barth J. Pharmacokinetics and pharmacodynamics of inhaled corticosteroids. J Allergy Clin Immunol 1998;101:S440–S446.
    OpenUrlCrossRefPubMedWeb of Science
  24. ↵
    Ketchell RI, Clarke GW, Jensen MW, Vos TP, Allenby MI, O'Connor BJ. Time course evaluation of the rapid effect of as single dose of inhaled fluticasone propionate on airway hyperresponsiveness to AMP in asthma (abstract). Am J Respir Crit Care Med 2003;A770:D55.
    OpenUrl
  25. ↵
    Mc Fadden ER. Inhaled glucosteroids and acute asthma; therapeutic breakthrough or nonspecific effect?. Am J Respir Crit Care Med 1998;157:677–678.
    OpenUrlPubMedWeb of Science
  26. ↵
    Feoktistov I, Polosa R, Holgate ST, Biaggioni I. Adenosine A2B receptors: a novel therapeutic target in asthma?. Trends Pharmacol Sci 1998;19:148–153.
    OpenUrlCrossRefPubMed
  27. ↵
    Kumar SD, Brieva JL, Danta I, Wanner A. Transient effect of inhaled fluticasone on airway mucosal blood flow in subjects with and without asthma. Am J Respir Crit Care Med 2000;161:918–921.
    OpenUrlCrossRefPubMedWeb of Science
  28. ↵
    Ketchell RI, Jensen MW, Clark GW, Allenby MI, O'Connor BJ. Rapid effect of single dose inhaled glucocorticosteroid on airway hyperresponsiveness to AMP in asthma is not molecule dependent (abstract). Am J Respir Crit Care Med 2003;A770:D54.
  29. ↵
    Anderson S, Smith CM. Osmotic challenges in the assessment of bronchial hyperresponsiveness. Am Rev Resp Dis 1991;143:S43–S46.
    OpenUrlPubMedWeb of Science
PreviousNext
Back to top
View this article with LENS
Vol 23 Issue 4 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Duration of effect of single-dose inhaled fluticasone propionate on AMP‐induced bronchoconstriction
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Duration of effect of single-dose inhaled fluticasone propionate on AMP‐induced bronchoconstriction
B. Luijk, R.D. Kempsford, A.M. Wright, P. Zanen, J-W.J. Lammers
European Respiratory Journal Apr 2004, 23 (4) 559-564; DOI: 10.1183/09031936.04.00043504

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Duration of effect of single-dose inhaled fluticasone propionate on AMP‐induced bronchoconstriction
B. Luijk, R.D. Kempsford, A.M. Wright, P. Zanen, J-W.J. Lammers
European Respiratory Journal Apr 2004, 23 (4) 559-564; DOI: 10.1183/09031936.04.00043504
Reddit logo Technorati logo Twitter logo Connotea logo Facebook logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Materials and methods
    • Results
    • Discussion
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Variability in the prevalence of premenstrual asthma
  • Parental occupation is a risk factor for childhood wheeze and asthma
  • Aerobic training reverses airway inflammation and remodelling in an asthma murine model
Show more Original Articles: Asthma

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society