Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • Peer reviewer login
  • Alerts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • Peer reviewer login
  • Alerts
  • Subscriptions

Acute effects of inspiratory pressure support during exercise in patients with COPD

A. van 't Hul, R. Gosselink, P. Hollander, P. Postmus, G. Kwakkel
European Respiratory Journal 2004 23: 34-40; DOI: 10.1183/09031936.03.00016903
A. van 't Hul
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Gosselink
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P. Hollander
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P. Postmus
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G. Kwakkel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The aim of the present study was to evaluate the acute effects of inspiratory pressure support (IPS) of 5 cmH2O (IPS5) and 10 cmH2O (IPS10) on exercise endurance.

Forty-five patients with COPD (mean forced expiratory volume in one second (FEV1)=39±14% pred) performed three constant-load endurance tests on a cycle ergometer at 75% of maximal workload. One test was without IPS, one test with IPS5, and one with IPS10. No statistically significant difference was found in exercise endurance between tests without IPS and IPS5 (4.2±2.6 versus 4.4±2.9 min).

In contrast, IPS10 resulted in a statistically significant increase in endurance compared with exercise without IPS (6.3±6.7 versus 4.2±2.6 min), as well as compared with exercise with IPS5 (6.3±6.7 versus 4.4±2.9 min). A wide scatter in individual responses to IPS was found, ranging from a deterioration of 1.6 min (−36%) to an improvement of 16.3 min (+445%). In only 15 patients, the increase in endurance exceeded the upper limit of the 95% confidence interval. Stepwise multiple regression analysis showed that maximal inspiratory pressure was the most important determinant of the increase in exercise endurance due to the application of IPS10.

It was concluded that in contrast to inspiratory pressure support of 5 cmH2O, the application of inspiratory pressure support of 10 cmH2O during exercise resulted in a statistically significant improvement in exercise endurance in patients with COPD compared with exercise without inspiratory pressure support. However, on an individual basis, large differences in responses were found. Inspiratory muscle weakness was revealed as a determinant of improvement in exercise endurance due to the application of inspiratory pressure support of 10 cmH2O, explaining only 24% of the variance in outcome.

  • Assisted ventilation
  • chronic obstructive pulmonary disease
  • exercise
  • pulmonary rehabilitation

This study was supported by a grant from the Dutch Asthma Foundation (grant 3.2.99.28).

Pulmonary rehabilitation programmes result in significant improvements in exercise capacity and quality of life in patients with chronic obstructive pulmonary disease (COPD) 1. Exercise training has been elicited as the cornerstone component of such programmes 2. Several interventions may be applied during exercise to improve training tolerance in patients with COPD, such as noninvasive ventilatory support (NIVS) 3. A recent systematic review on the acute effects of NIVS in patients with COPD revealed statistically significant summary effect sizes for the outcome measures, exertional dyspnoea and exercise endurance, in favour of NIVS 4. In all studies conducted on the acute effects of NIVS during exercise, to date, the effects of NIVS were compared with a “sham” type of NIVS in the form of continuous positive airway pressure (CPAP) of 1 cmH2O (CPAP1). However, it could be argued that the use of CPAP1 as a sham type of NIVS, requiring a breathing circuit (tubing and valve system of the ventilator), may result in an additional breathing resistance and subsequently become a deterrent to exercise performance. If so, this would lead to an overestimation of the effect of NIVS on exercise performance. To the best of the authors' knowledge, there are no studies available regarding the minimal intensity of NIVS required to compensate for the added breathing resistance resulting from the breathing circuit during exercise. However, it is suggested from studies in patients weaning from mechanical ventilation that 5 cmH2O is an inspiratory assist intensity required to overcome the additional work of breathing resulting from the ventilator plus tubing 5. On this basis it was hypothesised that inspiratory pressure support (IPS) of 5 cmH2O (IPS5) during exercise would have no effect on exercise endurance.

Regardless of the positive direct effects of NIVS on the group level, large differences were found in exercise responses between individual COPD patients. For instance in a study by Keilty et al. 6, improvements in walking distance as a result of the application of NIVS ranged 5–216%. For the purpose of implementation of NIVS in clinical practice, such as in exercise training during rehabilitation, it would be helpful if patient characteristics were recognised on the basis of which improvements in exercise endurance due to NIVS could be predicted. Since unloading the inspiratory muscles is found to be an important mechanism of the direct improvements in exertional dyspnoea and exercise endurance 7, 8, it may be hypothesised that inspiratory muscle performance, such as maximal inspiratory pressure (PI,max), is an important determinant.

The aim of the present study was to evaluate the direct effects of NIVS on exercise endurance during exercise, in the form of IPS of 5 and 10 cmH2O (IPS10), by comparison with a test without NIVS in patients with COPD. In addition, determinants of the relative improvement in exercise endurance due to the application of NIVS during exercise were investigated.

Methods

Study population

Patients with COPD, according to the criteria set by the Global Initiative for Obstructive Lung Disease scientific committee 9, referred for pulmonary rehabilitation were asked to participate in the present study. Patients had to meet the following inclusion criteria: 1) forced expiratory volume in one second (FEV1) ≤70% predicted; 2) the presence of a breathing reserve of <30% of maximal voluntary ventilation (defined as 37.5×FEV1) at peak exercise; 3) age between 40–75 yrs; 4) absence of other pathological conditions that could contribute to exercise limitation; and 5) informed consent was given. The Ethical Committee of the VU Medical Centre, Amsterdam, approved the study.

Measurements

Spirometry, plethysmography and single-breath diffusing capacity were performed according to the European Respiratory Society (ERS) recommendations 10. The method of Black and Hyatt 11 was used for the measurements of PI,max and maximal expiratory pressure (PE,max). Inspiratory muscle endurance (PI,end) was assessed by a 2‐min maximal incremental inspiratory threshold-loading test 12. Outcome on this test was related to reference values obtained in the authors' own laboratory 13.

A symptom-limited incremental cycle exercise test was conducted according to the ERS recommendations 14. The test was performed on a calibrated, electrically braked cycle ergometer (WLP 904; Lode, Groningen, The Netherlands) at a pedalling rate of 60 revolutions·min−1. During testing, work rate was increased by 10% of the estimated maximal workload until exhaustion. Maximal heart rate was determined using the RR interval from a three-lead electrocardiogram (HP78351A; Hewlett Packard, Andover, MA, USA). Peak minute ventilation (V'E,peak; L·min−1 at body temperature and ambient pressure, and saturated with water vapour) and peak oxygen uptake (V'O2,peak; mL·min−1, standard temperature pressure dry) were measured with a breath-by-breath automated exercise metabolic system (Vmax229; Sensormedics, Yorba Linda, CA, USA). Thirty minutes before the start of each test, the airflow sensor was calibrated with a 3‐L syringe and gas analysers were calibrated against known gases. Arterial blood samples were drawn from an indwelling catheter in the radial artery at rest and at maximal exercise. Maximal work rate (W,max) and V'O2,peak were related to the reference values of Jones and co-workers 15, 16. V'E,peak was related to the predicted maximal voluntary ventilation 17. After the test, patients were asked to state their main reason for stopping exercise, i.e. intolerable exertional dyspnoea, leg fatigue or a combination of these.

Symptom-limited exercise endurance was determined with a constant-load exercise test on a cycle ergometer at 75% of the previously determined W,max. The same cycle ergometer was used in the maximal exercise test. Patients were instructed to exercise for as long as possible. They were told to stop the exercise only when dyspnoea became intolerable and/or the required pedalling rate (60 revolutions·min−1) could not be kept up due to leg fatigue. During the test, encouragements were given every 2 min. If exercise endurance exceeded 20 min, the observer terminated the test. The test started when patients felt comfortable, and heart rate and oxygen saturation levels were at individual resting values. Before the tests, other forms of general exercise (testing) were avoided, and each test was preceded by a rest period of ≥15 min. Ventilatory and metabolic responses were measured using the same metabolic cart as in the incremental exercise test. Data were averaged over 20‐s time intervals. Ventilatory variables included the measurement of inspiratory capacity (IC) at rest and at 2‐min intervals during the test without IPS. To perform the IC manoeuvre, patients were instructed to inhale fairly quickly to total lung capacity after the end of a normal breath. The manoeuvre ended with a normal, unforced expiration 18. In the tests with IPS, the metabolic cart was connected to the expiratory port of the ventilator and used in the mixing chamber mode. Patients were requested not to eat or drink tea or coffee 2 h before each visit. The outcome ofaconstant-load cycle test has been shown to be highly reproducible in patients with COPD 19.

Chronic exertional dyspnoea was scored using the Medical Research Council (MRC) dyspnoea scale. The MRC dyspnoea scale allows classification of perceived breathlessness into five grades 20. Health status was assessed by means of the St George's Respiratory Questionnaire (SGRQ). The SGRQ is a self-report questionnaire and scores health status in three components: symptoms (dyspnoea, wheezing, coughing), activity (the severity to which activities of daily living are impaired by dyspnoea) and impacts (the influence of respiratory symptoms on social participation) 21.

Study design

Measurements took place during three visits. On the first visit, patients performed pulmonary function tests and a symptom-limited incremental exercise test. On the second visit, 1–2 weeks later, an endurance test was performed without IPS, and patients were familiarised with exercising with IPS because it was anticipated that exercise performance on IPS was susceptible to learning effects. On the third visit, two endurance tests were performed with IPS5 and IPS10, in a random order.

Noninvasive ventilatory support

NIVS was provided as IPS set at 5 and 10 cmH2O (Raphael; Hamilton AG, Thäzüns, Switzerland). The flow trigger was set at 3 L·min−1, i.e. the lowest possible value, and the inspiratory oxygen fraction at 21%. This ventilator has a capacity to support V'E up to 50 L·min−1 with a response time of 145 ms and a maximal inspiratory flow rate of 180 L·min−1. Patients were attached to the ventilator via corrugated tubing and mouthpiece, and a noseclip was applied. The dead space of the mouthpiece was <15 mL. It is the authors' experience that a mouthpiece is the most practical interface for the application of NIVS during exercise, because it produces less leakage of air compared with face masks and is better tolerated by patients. Ventilator inspiratory and expiratory breathing circuits were separated, which prevents the possibility of rebreathing.

Statistical analysis

Results are expressed as mean±sd. Differences in exercise endurance and physiological responses between the three constant-load tests were examined with a one-way analysis of variance. Post hoc analyses were performed with appropriate Bonferroni correction for multiple comparisons. Pearsons' correlation coefficients were calculated between the improvement in endurance with IPS10 and age, body length, body weight, pulmonary function and respiratory muscle performance indices, and physiological responses at peak exercise during the symptom-limited incremental and constant-load exercise test. Subsequently, a stepwise multiple regression analysis was performed to determine factors independently contributing to the improvement in exercise endurance due to the application of IPS10. Based on the literature, variables considered for use in the analysis were maximal respiratory pressures, inspiratory muscle endurance, end-exercise V'E2 during the constant-load test without IPS, arterial carbon dioxide tension (Pa,CO2) at rest and Pa,CO2 at peak exercise during the symptom-limited incremental exercise test 7, 8. To prevent exclusion of important independent variables as a result of lack of power (type‐II or 1‐β error), all variables from the univariate regression analysis with a p‐value of <0.20 were entered in the prediction model. For all tests, a two-sided significance level of 0.05 was used.

Results

Patient characteristics

Table 1⇓ illustrates the main characteristics of subjects included in the present study. Forty-five patients participated in the study with a mean age of 67±7 yrs and a mean FEV1 of 1.06±0.40 L (39±14% pred).

View this table:
  • View inline
  • View popup
Table 1

Characteristics of the 45 subjects

Table 2⇓ shows the results of the symptom-limited incremental exercise tests. Exercise capacity was markedly reduced in the patients. On average, the breathing reserve at maximal exercise was only 6±17%. Blood gases at rest and during exercise could be obtained in 33 patients. All but three patients had an increase in Pa,CO2 at maximal exercise compared with the resting value.

View this table:
  • View inline
  • View popup
Table 2

Incremental exercise test in the 45 subjects

Chronic exertional dyspnoea and health status

All participating patients had significant chronic exertional dyspnoea. Twenty-four patients had an MRC score of 3 (“I walk slower than people of the same age on the level because of breathlessness or have to stop for breath when walking at my own pace on the level”). Twenty-one patients had a score of 4 (“I stop for breath after walking 100 yards or after a few minutes on the level”). Also health status, measured by the SGRQ was markedly impaired (table 3⇓).

View this table:
  • View inline
  • View popup
Table 3

St George's respiratory questionnaire

Effects of inspiratory pressure support on exercise endurance

Results of the constant-load exercise tests are presented in table 4⇓. Seven of the 45 patients expressed their discomfort about the wearing of a noseclip and/or dryness of the throat during exercise with IPS. However, all patients were able to complete the protocol. No statistically significant difference was found in exercise endurance between exercise with IPS5 and a test without IPS (4.4±2.9 versus 4.2±2.6 min, p=0.70). However, the application of IPS10 during exercise resulted ina statistically significant increase in exercise endurance compared with IPS5 (6.3±6.7 versus 4.4±2.9 min, p<0.01), as well as compared with exercise without IPS (6.3±6.7 versus 4.3±2.6 min, p<0.01). The average improvement in exercise endurance was 2.2 min, with a 95% confidence interval of 1.3–3.3 min. Reasons to stop exercise on IPS5 and IPS10 did not differ from exercise without IPS. Thirty-three patients stopped exercise as a result of intolerable dyspnoea and 12 patients stopped owing to a combination of dyspnoea and leg discomfort.

View this table:
  • View inline
  • View popup
Table 4

Physiological responses in the 45 subjects during constant-load exercise tests

In figure 1⇓, an identity plot is shown of endurance of the exercise test without IPS and endurance on IPS10. Exercise endurance with IPS10, compared with exercise endurance without IPS, was higher in 27 patients (60%), remained unaltered in four patients (9%) and was lower in 14 patients (31%). In 15 patients, the improvement in exercise endurance was ≥100% (fig. 2⇓).

Fig. 1.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.—

Identity plot of exercise endurance without inspiratory support pressure (IPS) and with IPS of 10 cmH2O (IPS10).

Fig. 2.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.—

Relationship (r=−0.49, p=0.001) between improvement in exercise endurance and maximal inspiratory pressure (PI,max). IPS10: inspiratory pressure support of 10 cmH2O. •: patients with a change in exercise endurance <100%, n=15; ○: patients with a change in exercise endurance of ≥100% (at least doubled).

Effects of inspiratory pressure support on physiological responses

Compared with end-exercise with IPS5, IPS10 resulted at the isotime moment in a statistically significant increase in tidal volume (VT) and lower respiratory rate (RR), whereas V'E did not differ. Also V'O2 and carbon dioxide production (V'CO2) were significantly lower at the isotime moment. V'E, VT, V'O2 and V'CO2 were significantly higher at end exercise during exercise with IPS10, compared with end exercise with IPS5 (table 3⇑).

Determinants of effect of inspiratory pressure support on exercise endurance

In single regression analysis, significant correlations (r) were found for the improvement in exercise endurance with IPS10 and PI,max (r=−0.49, p<0.01), PE,max (r=−0.33, p<0.04), PI,end (r=−0.39, p<0.02), end exercise V'E in the constant-load test without IPS (r=−0.42, p<0.01), Pa,CO2 at rest (r=0.37, p<0.03), Pa,CO2 at peak exercise during the maximal incremental exercise test (r=0.37, p<0.03) and the Activity component of the SGRQ (r=0.38, p<0.05). No statistically significant correlation coefficients were found between improvement in exercise endurance and single-breath diffusing capacity (r=0.14, p=0.41), the change in IC during the unsupported constant-load exercise test (r=0.15, p=0.34) and the MRC score (r=0.14, p=0.34).

In stepwise multiple regression analysis, the only factor significantly contributing to the improvement in exercise endurance as a result of the application of IPS10 during exercise appeared to be PI,max. The computed regression model is Embedded Imagewhich could explain 24% of the variance in outcome (p<0.01). In figure 2⇑ the relationship is shown between improvement in exercise endurance and PI,max.

Discussion

The main finding of the present study is that the application of NIVS during exercise, in the form of IPS10, resulted in a statistically significant increase in exercise endurance compared with a test without IPS, as well as compared with exercise with IPS5, in patients with moderate-to-severe COPD. In contrast, IPS5 did not affect exercise endurance compared with exercise without IPS. Despite the inclusion of patients on the basis of a ventilatory impaired exercise capacity, IPS10 resulted in only 33% of the population in a marked increase in exercise endurance. The effects of IPS10 on exercise endurance could be predicted to a small degree (24%) on the basis of the PI,max.

To the best of the authors' knowledge, this is the first study in which the effects of NIVS were evaluated not only by comparing the effects of two intensities of IPS on constant-load exercise endurance, i.e. IPS5 and IPS10, but also by comparing these effects to exercise endurance without IPS. The statistically significant increase in exercise endurance due to IPS10 of ∼2 min confirms the results of other studies on the effects of IPS 6, 22. Interpretation of the significance of this effect is hampered for two reasons. At first, no data are available on the reliability of the measurement of the effect of IPS on exercise endurance. In the present study, exercise endurance on IPS was higher in 27 (60%) of the patients. However, in only 15 of the 45 patients (33%) the improvement in exercise endurance on IPS exceeded the upper limit of the 95% confidence interval (>3.3 min) of the average improvement. In these 15 patients, exercise endurance improved, on average by 7.5 min, and at least doubled on IPS. Secondly, the minimal clinically important difference in constant-load cycle endurance has yet to be determined 19.

In the present study, the effects of two different intensities of IPS were examined. This was because it could be argued that application of IPS of a low intensity may have a negative effect on exercise performance as a result of insufficient compensation for the increase in work of breathing, due to the resistance of the tubing circuit and valve system of the ventilator 5. In the present study, no difference in exercise endurance was present between exercise without IPS and exercise with IPS5, indicating the absence of a negative effect of IPS5 on exercise performance. The authors are unaware of studies in which the effects of CPAP1 during exercise were compared with exercise without ventilatory support. However, O'Donnell et al. found a statistically, significantly lower exercise endurance during exercise with CPAP1 compared with exercise with IPS5 in patients with chronic heart failure 23. Their findings, combined with the results of the present study, may suggest that CPAP1 has a negative influence on exercise endurance compared with exercise without IPS.

The increase in VT and decrease in RR during exercise with IPS is in agreement with earlier studies 7, 22. Due to the resulting improved alveolar ventilation, it may explain the slightly higher oxygen saturation at the isotime moment during exercise with IPS10 compared with end exercise without IPS and IPS5. The reduction in V'O2 and V'CO2 found in the present study at the isotime moment during exercise with IPS10 compared with end exercise with IPS5 supports the finding of the studies by Maltais et al. 7 and Petrof et al. 8 that inspiratory muscles are less loaded during exercise with IPS10. In patients with COPD, V'O2 of the ventilatory muscles during exercise may be a substantial part of the total V'O2 24. In addition, during ventilator weaning, Brochard et al. 25 found a good correlation between, on the one hand, the reduction in respiratory muscle activity due to IPS, and, on the other hand, the lower V'O2 of contracting ventilatory muscles.

In the present study, improvement in exercise endurance due to the application of IPS10 compared with unsupported exercise, ranged from a deterioration of 1.6 min (−36%) to an improvement of 16.3 min (+445%). To date, this is the first study attempting to predict the extent of improvements in exercise endurance due to IPS10 on the basis of pulmonary function and respiratory muscle function indices. A significant negative association was found (r=−0.49, p<0.01) between PI,max and the increase in exercise endurance. This finding concurs with the hypothesis that the improvements in exercise endurance due to the application of IPS are related to inspiratory muscle weakness. Polkey et al. 26 have demonstrated, in patients with COPD, that IPS during exercise may result in a delay in the initiation of the fatigue process in the inspiratory muscles. Since weakness makes the muscles susceptible to fatigue, it is likely that COPD patients with inspiratory muscle weakness may benefit most from unloading the inspiratory muscles 27. The significant correlation between improvement in exercise endurance on IPS10 and a high Pa,CO2, at rest and at maximal exercise, is also in keeping with the observed association between inspiratory muscle weakness and carbon dioxide retention in patients with COPD 28. The absence of significant correlation coefficients between, on theone hand, improvements in exercise endurance, and, on the other hand, diffusing capacity of the lung for carbon monoxide and the decrease in IC during unsupported constant-load exercise, suggest that regardless of the severity of the altered pulmonary mechanics in patients with COPD, NIVS results in improved exercise performance.

A potentially important mechanism of NIVS to improve exercise performance may be a reduction in exertional dyspnoea 7, 22. However, the authors did not attempt to measure such an effect because the primary aim of the present study was to measure the effects of two intensities of IPS on exercise endurance due to IPS10. In the present study, the order of testing was randomised, and thus dyspnoea ratings should have been collected during the exercise tests very often, i.e. every 30 s to allow appropriate comparisons of dyspnoea ratings between tests at identical exercise durations. It was anticipated that an accurate evaluation of the effect of IPS on exercise endurance would have been disturbed by such frequent dyspnoea ratings. In the present study, exertional dyspnoea contributed significantly to patients' exercise intolerance. Moreover, a statistically significant correlation was observed between the Activity component of the SGRQ and the increase in exercise endurance due to the application of IPS. This implies that patients with the highest impact of chronic exertional dyspnoea during activities of daily living may benefit the most from IPS to improve their training tolerance.

Despite the identification of determinants of a positive response to IPS in the present study, the predictive validity of these determinants was low. In a multiple regression model, PI,max was selected, explaining only 24% of the variance incycle endurance improvement. As a consequence, it is not possible to predict the individual exercise responses to IPS reliably. If training on assisted ventilation is considered, patients should be put through a trial session. However, patients without inspiratory muscle weakness (PI,max>±70 cmH2O) are the least likely to respond to IPS during exercise and should probably not be considered primary candidates for such an intervention.

The significant inverse correlation between improvement in exercise endurance and end exercise V'E in the constant-load exercise test without IPS may indicate an association between the impaired ventilatory capacity of the respiratory system of patients and the positive effect of IPS10 on exercise ability. Alternatively, this significant correlation may be caused by a “ceiling effect” due to the maximal capacity of the ventilator. The ventilator used in the present study could support ventilation to a maximal level of 50 L·min−1. It is possible that better results could be obtained by the use of a ventilator with a better technical performance than the ventilator used in the present study. However, only three patients had an end exercise V'E of ≥50 L·min−1 in the constant-load test without IPS, making it a less likely explanation. In addition, leaving out the results of these three patients did not affect the outcome of the analysis.

Blinding of patients was applied with respect to the order in which tests with IPS5 and IPS10 were performed. However, blinding of the observer to the application of IPS during exercise was in this experimental set-up not possible. The difference in sound intensity produced by the ventilator between IPS5 and IPS10 could easily be recognised by the observer. As a result, expectation bias could have influenced the results of the present study. However, the absence of a difference in the physiological responses at end exercise between exercise without IPS and with IPS5 suggests equality in the patients' efforts (and observer encouragements) between these tests.

Exercise training has been accepted as key component of rehabilitation programmes in patients with COPD, but the optimal length, duration, frequency and intensity of training sessions remain to be determined 29. Lower limb muscle alterations, like weakness and fatigability are frequently found in patients with COPD and contribute significantly to the impaired exercise capacity 30. Exercise training on NIVS, by increasing the ventilatory capacity and/or reducing the ventilatory load, may allow for higher training loads, and hence, a better outcome. Conversely, exercise on NIVS reduces the load on the respiratory muscles, which may prevent an adequate training stimulus to these muscles. Interestingly, Garrod et al. 31 found improvements in respiratory muscle function from general exercise training only when NIVS, applied during the night, was added.

To date, there are three studies published on the effects of training on noninvasive ventilatory support. None of these studies reported negative effects of training on noninvasive ventilatory support on respiratory muscle function 32–34. Since outcomes with respect to improvements in exercise capacity were inconsistent, more randomised controlled studies are required to determine the effect, if any, of exercise training on noninvasive ventilatory support on the outcome of rehabilitation programmes in patients with chronic obstructive pulmonary disease.

Acknowledgments

The authors would like to thank L. van der Schaaf, specialist respiratory nurse, and J. Berkovits, M. van Hengstum, P.M. Hooghiemstra, P. Kunst, P.I. van Spiegel, W.F.M Strankinga and A. Vonk Noordegraaf, chest physicians, for their efforts in the recruitment of patients for this study.

  • Received February 14, 2003.
  • Accepted July 19, 2003.
  • © ERS Journals Ltd

References

  1. ↵
    Lacasse Y, Brossea L, Milne S, et al. Pulmonary rehabilitation for chronic obstructive pulmonary disease. Cochrane Database Syst Rev 2002;3:CD003793.
  2. ↵
    Lacasse Y, Guyatt GH, Goldstein RS. The components of a respiratory rehabilitation program: a systematic overview. Chest 1997;111:1077–1088.
    OpenUrlCrossRefPubMedWeb of Science
  3. ↵
    Ambrosino N. Exercise and noninvasive ventilatory support. Monaldi Arch Chest Dis 2002;55:242–246.
    OpenUrl
  4. ↵
    van 't Hul AJ, Kwakkel G, Gosselink R. The acute effects of non-invasive ventilatory support during exercise on exercise endurance and dyspnea in patients with COPD: a systematic review. J Cardiopulm Rehabil 2002;22:290–297.
    OpenUrlCrossRefPubMed
  5. ↵
    Brochard L, Rua F, Lorino H, Lemaire F, Harf A. Inspiratory pressure support compensates for the additional work of breathing caused by the endotracheal tube. Anaesthesiology 1991;75:739–745.
    OpenUrlPubMedWeb of Science
  6. ↵
    Keilty SE, Ponte J, Fleming TA, Moxham J. Effect of inspiratory pressure support on exercise tolerance and breathlessness in patients with severe stable chronic obstructive pulmonary disease. Thorax 1994;49:990–994.
    OpenUrlAbstract/FREE Full Text
  7. ↵
    Maltais F, Reissmann H, Gottfried SB. Pressure support reduces inspiratory effort and dyspnea during exercise in chronic airflow obstruction. Am J Respir Crit Care Med 1995;151:1027–1033.
    OpenUrlPubMedWeb of Science
  8. ↵
    Petrof BJ, Calderini E, Gottfried SB. Effect of CPAP on respiratory effort and dyspnea during exercise in severe COPD. J Appl Physiol 1990;69:179–188.
    OpenUrlAbstract/FREE Full Text
  9. ↵
    Pauwels RA, Buist AS, Calverley PM, et al. Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary. Am J Respir Crit Care Med 2001;163:1256–1276.
    OpenUrlCrossRefPubMed
  10. ↵
    Quanjer PH, Tammeling GJ, Cotes JE, et al. Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. Eur Respir J 1993;6: Suppl. 16, 5–40.
    OpenUrlFREE Full Text
  11. ↵
    Black LF, Hyatt RE. Maximal respiratory pressures: normal values and relationship to age and sex. Am Rev Respir Dis 1969;99:696–702.
    OpenUrlPubMedWeb of Science
  12. ↵
    Martyn JB, Moreno RH, Pare PD, Pardy RL. Measurement of inspiratory muscle performance with incremental threshold loading. Am Rev Respir Dis 1987;135:919–923.
    OpenUrlPubMedWeb of Science
  13. ↵
    van 't Hul AJ, Chadwick-Straver RVM, Sol G, Boonstra A, Wagenaar RC. Maximal incremental inspiratory threshold loading: test-retest reliability and a range of reference. EurRespir J 1998;12: Suppl. 28, 353s.
    OpenUrl
  14. ↵
    Roca J, Whipp BJ, Agusti AN, et al. Clinical exercise testing with reference to lung disease – indications, standardization and interpretation strategies. Eur Respir J 1997;10:2662–2689.
    OpenUrlCrossRefPubMedWeb of Science
  15. ↵
    Jones NL, Makrides L, Hitchcock C, Chypchar T, McCartney P. Normal standards for an incremental progressive cycle ergometer test. Am Rev Respir Dis 1985;131:700–708.
    OpenUrlPubMedWeb of Science
  16. ↵
    Jones NL, Summers E, Killian KJ. Influence of age and stature on exercise capacity during incremental cycle ergometry in men and women. Am Rev Respir Dis 1989;140:1373–1380.
    OpenUrlPubMedWeb of Science
  17. ↵
    Carter R, Peavler M, Zinkgraf S, Williams J, Fields S. Predicting maximal exercise ventilation in patients with chronic obstructive pulmonary disease. Chest 1987;92:253–259.
    OpenUrlCrossRefPubMedWeb of Science
  18. ↵
    O'Donnell DE, Lam M, Webb KA. Measurement of symptoms, lung hyperinflation, and endurance during exercise in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 1998;158:1557–1565.
    OpenUrlCrossRefPubMedWeb of Science
  19. ↵
    van 't Hul AJ, Gosselink R, Kwakkel G. Constant-load cycle endurance performance: test-retest reliability and validity in patients with COPD. J Cardiopulm Rehabil 2003;23:143–150.
    OpenUrlCrossRefPubMed
  20. ↵
    Bestall JC, Paul EA, Garrod R, Garnham R, Jones PW, Wedzicha JA. Usefulness of the Medical Research Council (MRC) dyspnoea scale as a measure of disability in patients with chronic obstructive pulmonary disease. Thorax 1999;54:581–586.
    OpenUrlAbstract/FREE Full Text
  21. ↵
    Jones PW, Quirk FH, Baveystock CM, Littlejohns P. A self-complete measure of health status for chronic airflow limitation. The St. George's Respiratory Questionnaire. Am Rev Respir Dis 1992;145:1321–1327.
    OpenUrlCrossRefPubMedWeb of Science
  22. ↵
    Bianchi L, Foglio K, Pagani M, Vitacca M, Rossi A, Ambrosino M. Effects of proportional assist ventilation on exercise tolerance in COPD patients with chronic hypercapnia. Eur Respir J 1998;11:422–427.
    OpenUrlAbstract
  23. ↵
    O'Donnell DE, D'Arsigny C, Raj S, Abdollah H, Webb KA. Ventilatory assistance improves exercise endurance in stable congestive heart failure. Am J Respir Crit Care Med 1999;160:1804–1811.
    OpenUrlCrossRefPubMedWeb of Science
  24. ↵
    Evison H, Cherniack RM. Ventilatory cost of exercise in chronic obstructive pulmonary disease. J Appl Physiol 1968;25:21–27.
    OpenUrlFREE Full Text
  25. ↵
    Brochard L, Harf A, Lorino H, Lemaire F. Inspiratory pressure support prevents diaphragmatic fatigue during weaning from mechanical ventilation. Am Rev Respir Dis 1989;139:513–521.
    OpenUrlPubMedWeb of Science
  26. ↵
    Polkey MI, Kyroussis D, Mills GH, et al. Inspiratory pressure support reduces slowing of inspiratory muscle relaxation rate during exhaustive treadmill walking in severe COPD. Am J Respir Crit Care Med 1996;154:1146–1150.
    OpenUrlPubMedWeb of Science
  27. ↵
    Begin P, Grassino A. Inspiratory muscle dysfunction and chronic hypercapnia in chronic obstructive pulmonary disease. Am Rev Respir Dis 1991;143:905–912.
    OpenUrlCrossRefPubMedWeb of Science
  28. ↵
    Rochester DF. Respiratory muscle weakness, pattern of breathing, and CO2 retention in chronic obstructive pulmonary disease. Am Rev Respir Dis 1991;143:901–903.
    OpenUrlPubMedWeb of Science
  29. ↵
    Morgan DL, Calverly PMA, Clark CJ, et al. Pulmonary rehabilitation (BTS statement). British Thoracic Society Standards of Care Subcommittee on Pumonary Rehabilitation. Thorax 2001;56:827–834.
    OpenUrlFREE Full Text
  30. ↵
    Saey D, Debigare R, LeBlanc P, et al. Contractile leg fatigue after cycle exercise: a factor limiting exercise in patients with COPD. Am J Respir Crit Care Med 2003;168:425–430.
    OpenUrlCrossRefPubMedWeb of Science
  31. ↵
    Garrod R, Mikelsons C, Paul EA, Wedzicha JA. Randomized controlled trial of domiciliary noninvasive positive pressure ventilation and physical training in severe chronic obstructive pulmonary disease. Am J Respir Crit Care Med 2000;162:1335–1341.
    OpenUrlPubMedWeb of Science
  32. ↵
    Hawkins P, Johnson LC, Nikoletou D, et al. Proportional assist ventilation as an aid to exercise training in severe chronic obstructive pulmonary disease. Thorax 2002;57:853–859.
    OpenUrlAbstract/FREE Full Text
  33. Johnson JE, Gavin DJ, Adams-Dramiga S. Effects of training with heliox and noninvasive positive pressure ventilation on exercise ability in patients with severe COPD. Chest 2002;122:464–472.
    OpenUrlCrossRefPubMedWeb of Science
  34. ↵
    Bianchi L, Foglio K, Porta R, Baiardi R, Vitacca M, Ambrosino N. Lack of additional effect of adjunct of assisted ventilation to pulmonary rehabilitation in mild COPD patients. Respir Med 2002;96:359–367.
    OpenUrlCrossRefPubMedWeb of Science
View Abstract
PreviousNext
Back to top
View this article with LENS
Vol 23 Issue 1 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Acute effects of inspiratory pressure support during exercise in patients with COPD
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Acute effects of inspiratory pressure support during exercise in patients with COPD
A. van 't Hul, R. Gosselink, P. Hollander, P. Postmus, G. Kwakkel
European Respiratory Journal Jan 2004, 23 (1) 34-40; DOI: 10.1183/09031936.03.00016903

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Acute effects of inspiratory pressure support during exercise in patients with COPD
A. van 't Hul, R. Gosselink, P. Hollander, P. Postmus, G. Kwakkel
European Respiratory Journal Jan 2004, 23 (1) 34-40; DOI: 10.1183/09031936.03.00016903
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Methods
    • Results
    • Discussion
    • Acknowledgments
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Novel strategy to identify genetic risk factors for COPD severity: a genetic isolate
  • Calculating gambling odds and lung ages for smokers
  • Atrophy and hypertrophy signalling in the diaphragm of patients with COPD
Show more Original Articles: COPD

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society