Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • For authors
    • Instructions for authors
    • Submit a manuscript
    • Author FAQs
    • Open access
    • COVID-19 submission information
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • For authors
    • Instructions for authors
    • Submit a manuscript
    • Author FAQs
    • Open access
    • COVID-19 submission information
  • Alerts
  • Podcasts
  • Subscriptions

Protection against methacholine-induced bronchospasm: salbutamol pMDI versus Clickhaler® DPI

M.T. Newhouse, P. Patel, M. Parry-Billings
European Respiratory Journal 2003 21: 816-820; DOI: 10.1183/09031936.03.00045902
M.T. Newhouse
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P. Patel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Parry-Billings
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Passive dry-powder inhalers (DPIs) have been developed as an alternative to pressurised metered-dose inhalers (pMDIs) to improve aerosol delivery on inhalation and eliminate the need for propellants. However, new DPI formulations of generic drugs must be rigorously compared with conventional pMDI therapy.

This randomised, double-blind, double-dummy, placebo-controlled, seven-way crossover study evaluated bronchoprotection from methacholine challenge in order to compare a novel salbutamol DPI (Clickhaler®) with a reference salbutamol pMDI (Ventolin®). Adult asthma patients with airway hyperresponsiveness to methacholine (provocative concentration of methacholine causing a 20% fall in the forced expiratory volume in one second (PC20) <4 mg·mL−1) were treated on separate days with 0, 100, 200 or 400 µg of salbutamol via the DPI or pMDI. Methacholine challenge was performed before and after salbutamol treatment and the PC20 ratios analysed by Finney's bioassay to test for therapeutic equivalence of the inhalers.

Eighteen patients completed the study and showed significant dose-related responses to salbutamol. The relative potency of DPI:pMDI was 1.29 (90% confidence interval 1.04–1.63). There were no treatment differences in safety (cardiac frequency, blood pressure, adverse events).

Methacholine-challenge methodology provides a sensitive bioassay and has demonstrated therapeutic equivalence of the salbutamol Clickhaler® dry-powder inhaler with the conventional salbutamol pressurised metered-dose inhaler.

  • airway hyperresponsiveness
  • bioequivalence
  • Clickhaler®
  • dry-powder inhaler
  • methacholine challenge
  • salbutamol

This study was supported by Innovata Biomed Ltd.

Salbutamol, the β2‐agonist bronchodilator most commonly used in the treatment of asthma, has been administered using pressurised metered-dose inhalers (pMDIs) and pressurised chlorofluorocarbon (CFC) propellants for the past 30 yrs. Substituting “ozone-friendly” alternatives puts the onus on the pharmaceutical industry to produce cost-effective replacement inhalers and establish that the switch-over from CFC pMDIs does not compromise patient care 1. Each new device/formulation is a unique combination that must satisfy strict regulatory requirements 2.

Pharmaceutical research and development has followed two major pathways: upgrading pMDIs with hydrofluoroalkanes (HFAs) as chlorine-free propellants, and innovative design of efficient dry-powder inhalers (DPIs) 3, 4. The activity of inhaled medications in the lung is determined by the amount of drug entering the lower respiratory tract 5, which is dependent on the mass of particles of ∼1–5 µm diameter and inspiratory flow velocity through the device 6. Changes of formulation, humidity, device or handling may alter drug mass or deposition, with implications for both safety and efficacy 7–9. Rapid systemic absorption of inhaled salbutamol occurs mainly at the vascular lung surface and the risk:benefit ratio can change with improved deposition 10. In-vitro data therefore need the support of clinical studies to elucidate drug bioavailability 11, 12.

Sequential measurement of the forced expiratory volume in one second (FEV1) in mild, stable asthmatics is commonly used to assess bronchodilator efficacy and compare new inhalers with existing standards 13. Valid comparison requires two or more doses of each drug since using single doses gives no information as to whether the bronchodilator effect has reached a plateau 14. Parallel dose/response curves can then be used to determine doses with an equivalent pharmacodynamic effect and the potency ratio calculated, with a value of 1.0 indicating bioequivalence 15. However, with available clinical formulations of salbutamol it is often difficult to achieve submaximal responses and bronchoconstrictor challenge methods are increasingly being used to improve the sensitivity of bioequivalence testing 16.

Adult patients with moderate, stable asthma, who screened positive for hyperresponsiveness to inhaled methacholine, showing dose/response to salbutamol bronchoprotection, were recruited accordingly to compare the clinical effectiveness of a new salbutamol DPI with a widely used pMDI.

Materials and methods

Patients

Male and female patients (≥18 yrs) with moderate stable asthma were enrolled at the initial screening visit if they showed a baseline FEV1 of ≥70% predicted and hyperresponsiveness to inhaled methacholine, evidenced by a provocative concentration causing a 20% fall in FEV1 (PC20) at a concentration of ≤4 mg·mL−1. Patients were additionally screened for PC20 dose/response to 100 and 200 µg of salbutamol via pMDI, and had to demonstrate correct use of the DPI and pMDI, using open-label placebo devices according to the manufacturers' instructions, achieving an inspiratory flow of 30 L·min−1 (±25%). Inhalation was from functional residual capacity (FRC) to total lung capacity (TLC), the flow being confirmed by a computerised monitor, which provided a target rate and range for the patient to achieve 17. Eligible patients had been nonsmokers for ≥6 months, with a maximum smoking history of 5 pack-yrs. Use of inhaled corticosteroids, sodium cromoglycate or nedocromil sodium was permitted if the dose had been stable for ≥4 weeks.

Exclusion criteria included any current or past medical condition other than asthma that might significantly affect the pharmacodynamic response to salbutamol or any condition within the last 6 weeks that could affect airway reactivity to methacholine. Further reasons for exclusion included: hypersensitivity to salbutamol, lactose, methacholine or any component of the pMDI or DPI and hospitalisation for acute asthmatic symptoms, or oral steroid treatment, within the previous 3 months. Females who were breastfeeding, pregnant or likely to become pregnant were also excluded. Patients with a history of seasonal asthma exacerbations were not excluded if they were studied outside the relevant allergen season. The study was carried out in accordance with the ethical principles of the Declaration of Helsinki and the protocol was reviewed and approved by the Independent Ethics Committees associated with each centre. All patients gave written informed consent at the start of the first study visit.

Study design

This was a randomised, double-blind, double-dummy, placebo-controlled seven-way crossover study, carried out at two hospital physician centres in Canada. The study consisted of 2 screening days (visits 1 and 2) and 7 test days (visits 3–9). At visit 1, demographics, medical history, drug therapy and vital signs were recorded (table 1⇓). Hyperresponsiveness to methacholine and dose/response to salbutamol were established by methacholine PC20 measurements at visits 1 and 2 (table 2⇓). Patients who met all the eligibility criteria at screening were randomised to study treatment and received three doses of salbutamol and a placebo from each inhaler during visits 3–9.

View this table:
  • View inline
  • View popup
Table 1

Patient characteristics at entry to the study (visit 1)

View this table:
  • View inline
  • View popup
Table 2

Baseline lung function (visit 1) and salbutamol dose/response in the methacholine- challenge test at screening (visits 1 and 2)

Study days were separated by ≥48 h and all visits fell within a 60-day period for each patient. Routine asthma medication was continued between visits, but before each study day the patients had to discontinue short-acting inhaled β2‐agonists for 6 h, long-acting β2‐agonists for 48 h, short-acting oral β2‐agonists for 12 h, long-acting oral β2‐agonists for 24 h and theophylline for 48 h. They were also not to take an antihistamine within 96 h. Caffeine-containing beverages were discontinued for 8 h and alcohol for 24 h before study visits. Visits started at the same time of day for each patient, generally between 08:30–10:00 h. A light meal was allowed ≥1 h before the first challenge but only water (and a light snack if required) during the testing session. Patients refrained from exercise or exposure to cold air throughout the visit.

At each visit, stability of the patient's asthma was assessed by a pulmonologist, who determined whether they had experienced deterioration since the last visit in exercise tolerance, nocturnal awakening, morning chest tightness and bronchodilator use. Baseline FEV1 and methacholine PC20 values were determined. If baseline FEV1 was not within 85–115% or baseline PC20 within 50–200% of visit‐1 values, the treatment visit was rescheduled (up to three times). Continued baseline instability led to the patient being withdrawn. Adverse events and changes in concomitant medication or coexistent diseases were also recorded at each visit.

Methacholine challenge

A baseline FEV1 was measured at each visit, taking the lowest of three reproducible (±5%) recordings, followed by a standard methacholine challenge test to determine the baseline PC20. Methacholine solutions, diluted in 0.9% saline and sterilised, were prepared by the study pharmacist in doubling concentrations from 0.03–256 mg·mL−1. Aerosols were inhaled by tidal breathing for 2 min from an English Wright Jet Nebuliser (Aerosol Medical Ltd, Colchester, UK) at an output of 0.13 mL·min−1, using the methodology established by Juniper et al. 16 and Siersted et al. 18. Starting concentrations of methacholine (0.03–0.125 mg·mL−1) were determined by the investigator for each patient, based on inhaled corticosteroid therapy and the response to 0.9% sterile saline. FEV1 was measured 30, 90 and 180 s after each inhalation, then at 2‐min intervals until it began to recover. A single FEV1 recording was made each time (if technically unsatisfactory, this was repeated after 10 s). If no decrease in FEV1 was observed within 5 min after one inhalation of methacholine, the patient moved on to inhale a higher concentration. The test ended when FEV1 decreased by ≥20% from baseline, allowing calculation of the PC20.

Salbutamol dose/response

At visits 1 and 2, patients were treated with one (100 µg) or two actuations (200 µg) from an open-label salbutamol pMDI (Ventolin®; Allen and Hanburys Ltd, Uxbridge, UK), 2 h 45 min after a baseline methacholine test, followed by a second methacholine challenge 15 min later. Dose order for each patient was randomised. Sixty minutes after the post-treatment challenge, all patients received 200 µg of salbutamol via a standard pMDI and FEV1 was measured after 15 min to check that it had recovered to near baseline level before the patient was allowed to leave the clinic. For study eligibility, PC20 after two actuations of the salbutamol pMDI had to be more than the PC20 after one actuation (a dose:response ratio of ≥2.0 was specified initially, but this proved too stringent in a large number of the patients screened).

Study treatments

Patients eligible at screening were randomised to seven treatment visits on separate days, during which they received salbutamol (100, 200 or 400 µg) via the DPI or standard pMDI, or placebo. They also received placebo from the alternative device at each visit. Since both devices delivered 100 µg per actuation, each study treatment required the patient to inhale once from eight coded inhalers (four DPIs and four pMDIs). The DPIs (Innovata Biomed Ltd, St. Albans, UK) contained either micronised salbutamol sulphate and lactose or lactose only. pMDI salbutamol was administered from Ventolin® pMDIs. Placebo pMDIs, having a similar content minus the salbutamol, were manufactured by Miza Ltd (Runcorn, UK), who also code-labelled and packaged all inhalers used in the study. In order to standardise the conditions of the methacholine challenge test and for patient safety, the investigators (but not the subjects) were aware of which dose of salbutamol patients received, although they were not aware of which device it was delivered from. At each treatment visit, patients confirmed their correct technique with placebo devices before using the study inhalers. pMDIs were primed by shaking and discharge to waste (not into the clinic air) five times, at 30–60-s intervals, and were then placed in the valve-up position for 1–30 min before dosing. DPIs and pMDIs were shaken immediately before each actuation. Patients inhaled (30 L·min−1) from FRC to TLC and held their breath for a few seconds after each inhalation.

After 2 h 45 min from methacholine challenge, patients received the test medication, followed by a further methacholine challenge 15 min later. Post-treatment methacholine concentrations started at visit‐1 baseline levels following placebo or 100 µg salbutamol, and at two concentrations below previously screened PC20 values for 100 and 200 µg salbutamol, respectively, following treatment with 200 and 400 µg salbutamol. Vital signs (blood pressure, respiratory rate and cardiac frequency by 3‐lead electrocardiogram (ECG) rhythm strip) were recorded 15 min before and 5 and 15 min after the first challenge test, 15 min after study treatment, immediately before the second challenge test and 5, 15 and 60 min after the second challenge test. Patients then received 200 µg salbutamol via standard pMDI and FEV1 was measured 15 min later to check recovery to near baseline value before they left the clinic.

Statistical analysis

PC20 values were determined by linear interpolation of methacholine concentration (log mg·mL−1) against percentage decrease in FEV1 from baseline. The response of FEV1 to each methacholine concentration was calculated by the investigator as: Embedded ImageThe percentage decrease in FEV1 was then plotted against the concentration (mg·mL−1) of methacholine on a logarithmic scale and the PC20 determined as follows: Embedded Imagewhere R1 is the percentage decrease in FEV1 (<20%) due to penultimate concentration (C1) and R2 is the percentage decrease in FEV1 (>20%) due to last concentration (C2).

The primary efficacy end-point was the drug activity ratio (PC20 post-treatment:PC20 pretreatment) for each dose of salbutamol from each device. The dose/response relationship of drug activity ratio with salbutamol dose was compared for the two inhalers using Finney bioassay analysis of variance methods to calculate relative potency and 90% confidence interval (CI) based on Food and Drug Administration (FDA) guidance for generic drugs 1, 15, 19. This required per protocol analysis of completed patients, with standard tests for validity (linearity, parallelism and regression) of the dose/response comparison 20. Power calculations based on published data for drug activity ratios were used to estimate a minimum sample size of 16 patients 21, 22.

Safety parameters (any adverse events, vital signs and changes in concomitant medication) were summarised for all screened patients and considered on a case-by-case basis, as appropriate.

Results

Sixty-three patients were screened, of whom only 26 were eligible for randomisation to treatment and 18 completed the study. Screening data for eligible and completing patients are summarised in tables 1 and 2⇑⇑. No important differences were apparent between the randomised group and those who completed. Of the eight patients who failed to complete study treatment, five were withdrawn due to instability of baseline PC20, one due to the onset of the allergy season, one because of a spirometer malfunction and one because they were unable to complete the study in time.

The dose-related effects of salbutamol on PC20 complied with Finney bioassay validity criteria, showing linear dose/responses with no significant deviation from parallelism or overlap between the two devices 15. Drug activity ratios for treatment with 100, 200 and 400 µg salbutamol via DPI or pMDI, or placebo, are shown in table 3⇓. The potency ratio of the study treatments based on the drug activity ratio was 1.29 (90% CI: 1.04–1.63), i.e. one actuation of the DPI is equivalent to ∼1.3 actuations of the pMDI.

View this table:
  • View inline
  • View popup
Table 3

Drug activity ratio (post:pretreatment provocative concentration of methacholine causing a 20% fall in the forced expiratory volume in one second (PC20)) for treatment with 100, 200 and 400 µg salbutamol via a dry-powder inhaler (DPI) or pressurised metered-dose inhaler (pMDI), or placebo

The overall incidence of adverse events was very low, the most common event (incidence 0.1%) being headache during the screening period. No serious adverse events or clinically important changes in vital signs occurred during the study and there were no treatment-associated differences in safety parameters.

Discussion

This pharmacodynamic study followed FDA guidelines in establishing therapeutic equivalence of the salbutamol Clickhaler®, a breath-actuated reservoir DPI 23, with the conventional Ventolin® pMDI in adult patients with stable, moderate asthma 1, 15. Validated methods for bronchodilator bioequivalence studies have only recently been clearly defined as requiring at least two doses of each treatment and adequate group sizes to establish a potency ratio 14, 19. Challenge methods are increasingly used to help achieve these conditions. For example, crossover studies of salbutamol Turbuhaler® and pMDI required 23 patients to assess bronchoprotective effects against methacholine 24, whereas direct assessment of bronchodilation required ≥40 evaluable patients 7. Methacholine-induced bronchoconstriction is now widely accepted as a method of increasing the sensitivity of the efficacy end-point in assessing inhaled β2‐agonists, and was recently validated in a bioequivalence study of HFA and CFC pMDIs 25. This placebo-controlled crossover study required 18 asthmatic patients to compare 100, 200, and 400 µg doses of salbutamol from the two devices and Finney bioassay showed a potency ratio of 1.08, confirmed using the nonlinear Emax model 15, 25.

The crossover, single-dose/separate-day study design has the potential disadvantage of inaccuracies resulting from variations in baseline FEV1 and PC20. Methodological studies suggest that inter-occasion variability should be accounted for in the statistical evaluation of the β2‐agonist dose/response and potency ratio, whether using linear or nonlinear mixed effects models 26. Variability can be reduced by imposing limits on the baseline measurements for each treatment day, as observed in the present study, for which a minimum requirement of 16 evaluable patients was estimated, based on validated histamine challenge bioassays of salbutamol 21, 22. Although 20% of the randomised patients had to be withdrawn owing to variation in baseline PC20, 18 patients remained to provide per protocol data for three doses of each treatment 1, 15. In recruiting sufficient subjects, it was found that the FDA recommendation for PC20 responsiveness to 200:100 µg salbutamol (a response ratio of ≥2.0) was too stringent 1. Moderation of this entry criterion was justified by achievement of significant salbutamol dose/responses with both inhalers, showing no impact on the study outcome. The potency ratio of 1.29 suggests a slightly improved lung deposition of salbutamol from the Clickhaler® compared with the pMDI. This difference is not considered clinically relevant but may support the increased sensitivity of bronchoprotective assessments.

Recent Turbuhaler® studies have confirmed that pulmonary deposition data obtained by pharmacokinetic methods provide a useful surrogate for measuring the overall clinical response to inhaled β2‐agonists 13, 27. However, the practical relevance of the greater deposition and bronchoprotective potency of terbutaline via Turbuhaler® is obscured by the abnormally high inspiratory flow (90 L·min−1) used with the pMDI 27. In this study clinically relevant inspiratory flows for Clickhaler® and pMDI were used, consistent with previous bronchodilator studies 17, 28. In a cumulative dose/response study, these devices showed an FEV1 efficacy ratio close to 1.0 when comparing a submaximal nominal dose of salbutamol (100 µg) in patients with mild, moderate or severe asthma 28. The maximum change in FEV1 following inhalation of 200 µg salbutamol at 15, 30 or 60 L·min−1 from the Clickhaler® again matched the optimally used (30 L·min−1) pMDI 17, whilst supportive pharmacokinetic data demonstrate similar relative lung bioavailability of salbutamol from the Clickhaler® at fast (60 L·min−1) or slow (30 L·min−1) inhalation rates 29.

Breath-actuated DPIs have an environmental advantage over pMDIs in avoiding potential hazards of ozone destruction and global warming associated with propellant gases 30. Breath actuation also obviates difficulties in coordinating actuation and inhalation, which many patients experience with the “press and breathe” pMDI 31. A disadvantage associated with some DPIs is the rapid inhalation manoeuvre required for optimal actuation 3, 7, 27. This contrasts with the pMDI, which is more effective using slower inhalation 32. It also raises concerns over the effective use of DPIs by paediatric asthma patients aged <6 yrs and others who may be unable to achieve sufficient flow rates. DPI development is addressing these problems. The Clickhaler® requires a deep inhalation for optimal lung delivery but is driven by patient effort alone, relying on design features and optimised formulations to minimise flow-rate dependence 17, 29, 32. Asthmatic children aged >6 yrs are able to generate sufficient inspiratory flow and can reliably inhale initially, following appropriate instruction, to operate the DPI 33, which as a potential replacement mimics the familiar shape and handling of the pMDI 32. Simplicity and acceptability may influence a patient's compliance with inhaled treatments and are important factors in cost-effectiveness.

To conclude, salbutamol is the world's most widely used bronchodilator but environmental concerns are pressing for the provision of bioequivalent replacements for the chlorofluorocarbon-driven pressurised metered-dose inhalers 30. This study has employed validated methods to demonstrate that the Clickhaler® dry-powder inhaler delivers comparable amounts of salbutamol to the lungs of asthmatic patients to a correctly used chlorofluorocarbon-pressurised metered-dose inhaler.

Acknowledgments

The authors would like to thank all their colleagues and patients who took part in the study. They would also like to thank A. Scrimgeour for the statistical analysis and P. Riley for valuable input to the manuscript.

  • Received May 29, 2002.
  • Accepted January 6, 2003.
  • © ERS Journals Ltd

References

  1. ↵
    Division of Bioequivalence, Office of Generic Drugs, Food and Drug Administration. Interim guidance for documentation of in vivo bioequivalence of albuterol inhalation aerosols (metered dose inhalers)Rockville MD, FDA, 1994.
  2. ↵
    Snell NJC. Equivalence testing - the special case of inhaled medications. Int J Pharm Med 1998;12:245–246.
  3. ↵
    Leach CL. Approaches and challenges to use of freon propellant replacements. Aerosol Sci Technol 1995;22:328–334.
  4. ↵
    Dhand R, Fink J. Dry powder inhalers. Respir Care 1999;44:940–951.
  5. ↵
    Pauwels R, Newman S, Borgstrom L. Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers. Eur Respir J 1997;10:2127–2138.
  6. ↵
    Timsina MP, Martin GP, Marriott C, Ganderton D, Yianneskis M. Drug delivery to the respiratory tract using dry powder inhalers. Int J Pharm 1994;101:1–13.
  7. ↵
    Lofdahl C-G, Andersson L, Bondesson E, et al. Differences in bronchodilating potency of salbutamol in Turbuhaler® as compared with a pressurized metered-dose inhaler formulation in patients with reversible airway obstruction. Eur Respir J 1997;10:2474–2478.
  8. Clark DJ, Lipworth BJ. Lung bioavailability of chlorofluorocarbon free, dry powder and chlorofluorocarbon containing formulations of salbutamol. Br J Clin Pharmacol 1996;41:247–249.
  9. ↵
    Hindle M, Peers EM, Parry-Billings M, Chrystyn H. Relative bioavailability of salbutamol to the lung following inhalation via a novel dry powder inhaler and a standard metered dose inhaler. Br J Clin Pharmacol 1997;43:336–338.
  10. ↵
    Lipworth BJ. New perspectives on inhaled drug delivery and systemic bioactivity. Thorax 1995;50:105–110.
  11. ↵
    Chrystyn H, Allen MB, Corlett SA, Tomlinson HS. Simultaneous measurement of pharmacodynamic and pharmacokinetic parameters which can be used to evaluate the equivalence of inhaled salbutamol. Am J Respir Crit Care Med 1998;157:A636.
  12. ↵
    Hindle M, Newton PAG, Chrystyn H. Investigations of an optimal inhaler technique using urinary salbutamol as a measure of relative bioavailability to the lung. Thorax 1993;48:506–511.
  13. ↵
    Buck H, Parry-Billings M. Discriminating measures of bronchodilator drug efficacy and potency. Br J Clin Pharmacol 2001;52:245–253.
  14. ↵
    Ahrens RC. On comparing inhaled beta adrenergic agonists. Ann Allergy 1991;67:296–298.
  15. ↵
    Finney DJ.. Statistical Methods in Biological Assay. 3rd EdnLondon, Charles Griffin & Co. Ltd, 1978; pp. 105–147.
  16. ↵
    Juniper EF, Frith PA, Hargreave FE. Airway responsiveness to histamine and methacholine: relationship of minimum treatment to control symptoms of asthma. Thorax 1981;36:575–579.
  17. ↵
    Newhouse MT, Nantel NP, Chambers C, Pratt B, Parry-Billings M. Clickhaler (a novel dry powder inhaler) provides similar bronchodilation to pressurized metered-dose inhaler, even at low flow rates. Chest 1999;115:952–956.
  18. ↵
    Siersted HC, Walker CM, O'Shaughnessy AD, Willan AR, Wiecek EM, Sears MR. Comparison of two standardized methods of methacholine inhalation challenge in young adults. Eur Respir J 2000;15:181–184.
  19. ↵
    Parameswaran K. Concepts of establishing clinical bioequivalence of chlorofluorocarbon and hydrofluoroalkane β‐agonists. J Allergy Clin Immunol 1999;104:S243–S245.
  20. ↵
    Stewart BA, Ahrens RC, Carrier S, et al. Demonstration of in vivo bioequivalence of a generic albuterol metered-dose inhaler to Ventolin. Chest 2000;117:714–721.
  21. ↵
    Blake KV, Hoppe M, Harman E, Hendeles L. Relative amount of albuterol delivered to lung receptors from a metered-dose inhaler and nebulizer solution: bioassay by histamine provocation. Chest 1992;101:309–315.
  22. ↵
    Ahrens RC, Harris JB, Milavetz G, Annis L, Ries RA. Use of bronchial provocation with histamine to compare the pharmacodynamics of inhaled albuterol and metaproterenol in asthmatic patients. J Allergy Clin Immunol 1987;79:876–882.
  23. ↵
    Parry-Billings M, Boyes RN, Clisby LM, Braithwaite P, Williams S, Harper AE. Design, development, and performance of a novel multidose dry-powder inhaler. Pharm Technol 1999;23:70–81.
  24. ↵
    Wong AG, O'Byrne PM, Lindbladh C, Inman MD, Stahl E, Hargreave FE. Dose-response protective effect of salbutamol on methacholine airway responsiveness using pressurized metered dose inhalers and Turbuhalers. Can Respir J 1998;5:119–123.
  25. ↵
    Parameswaran KN, Inman MD, Ekholm BP, et al. Protection against methacholine bronchoconstriction to assess relative potency of inhaled β2‐agonist. Am J Respir Crit Care Med 1999;160:354–357.
  26. ↵
    Lalonde RL, Ouellet D, Kimanani EK, Potvin D, Vaughan LM, Hill MR. Comparison of different methods to evaluate population dose-response and relative potency: importance of interoccasion variability. J Pharmacokinet Biopharm 1999;27:67–83.
  27. ↵
    Derom E, Borgström L, Van Schoor J, Löfroos A‐B, Pauwels R. Lung deposition and protective effect of terbutaline delivered from pressurized metered-dose inhalers and the Turbuhaler in asthmatic individuals. Am J Respir Crit Care Med 2001;164:1398–1402.
  28. ↵
    Morice AH, Peake MD, Allen MB, Campbell JC, Parry-Billings M. Reproducibility of bronchodilator response for a reservoir dry powder inhaler following routine clinical use. J Asthma 2000;37:81–87.
  29. ↵
    Chege JK, Chrystyn H. The relative bioavailability of salbutamol to the lung using urinary excretion following inhalation from a novel dry powder inhaler: the effect of inhalation rate and formulation. Respir Med 2000;94:51–56.
  30. ↵
    The International Pharmaceutical Aerosol Consortium (IPAC). Enviros March. Study on the use of HFCs for metered dose inhalers in the European Union. Final Report following submission to the ECCPhttp://www.ipacmdi.com/documents/Enviros_report.pdf. 1st December 2000 (accessed 27 February 2003).
  31. ↵
    McFadden ER Jr. Improper patient techniques with metered dose inhalers: clinical consequences and solutions to misuse. J Allergy Clin Immunol 1995;96:278–283.
  32. ↵
    Smith IJ, Parry-Billings M. The inhalers of the future? A review of dry powder devices on the market today. Pulm Pharmacol Ther 2003;16:81–98.
  33. ↵
    Parry-Billings M, Birrell C, Oldham L, O'Callaghan C. Inspiratory flow rate through a dry powder inhaler (Clickhaler®) in children with asthma. Pediatr Pulmonol 2003;35:220–226.
PreviousNext
Back to top
View this article with LENS
Vol 21 Issue 5 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Protection against methacholine-induced bronchospasm: salbutamol pMDI versus Clickhaler® DPI
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Alerts
Sign In to Email Alerts with your Email Address
Citation Tools
Protection against methacholine-induced bronchospasm: salbutamol pMDI versus Clickhaler® DPI
M.T. Newhouse, P. Patel, M. Parry-Billings
European Respiratory Journal May 2003, 21 (5) 816-820; DOI: 10.1183/09031936.03.00045902

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Protection against methacholine-induced bronchospasm: salbutamol pMDI versus Clickhaler® DPI
M.T. Newhouse, P. Patel, M. Parry-Billings
European Respiratory Journal May 2003, 21 (5) 816-820; DOI: 10.1183/09031936.03.00045902
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Materials and methods
    • Results
    • Discussion
    • Acknowledgments
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Variability in the prevalence of premenstrual asthma
  • Parental occupation is a risk factor for childhood wheeze and asthma
  • Aerobic training reverses airway inflammation and remodelling in an asthma murine model
Show more Original Articles: Asthma

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • CME
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Submit a manuscript
  • ERS author centre

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2021 by the European Respiratory Society