Abstract
Eosinophilic airway inflammation is one of the hallmarks of asthma. Sputum eosinophilia has been suggested as a predictor of the response to inhaled corticosteroids in asthma. This study sought to investigate the proportion of steroid-naive uncontrolled asthmatics without significant sputum eosinophilia (≤1%) and to examine whether sputum eosinophilia could predict the response to inhaled corticosteroids.
A total of 51 mild uncontrolled steroid-naive asthmatics who had not been treated with oral or inhaled corticosteroids for at least 3 months were investigated. The evaluation included a spirometry, methacholine inhalation challenge and sputum induction on two occasions, one at baseline and the other after 1 month of treatment with 250 µg twice-daily fluticasone propionate.
Of the 51 subjects, 15 had an eosinophil count ≤1%, and 46 completed the two visits. Patients with baseline sputum eosinophils ≤1% (n=14) were compared with those with sputum eosinophils >1% (n=32). The baseline characteristics of these two groups were similar. After 1 month of treatment, respiratory symptoms, quality of life, forced expiratory volume in one second (FEV1) and provocative concentration causing a 20% fall in FEV1 improved in both groups.
The absence of sputum eosinophilia does not seem to be an indicator of poor response to inhaled corticosteroid treatment in steroid-naive asthmatics. However, this finding needs to be investigated further in a double-blind, placebo-controlled study, entirely designed to answer this question.
This study was funded by Réseau en santé respiratoire du FRSQ and GlaxoSmithKline Canada. C. Lemière and J-L. Malo are scholars of the Fonds de la recherche en santé du Québec.
Current asthma definition and guidelines emphasise the importance of airway inflammation in asthma. The eosinophil has been seen as a key cell in the pathophysiology of asthma 1, 2. The number of eosinophils correlates with the level of airflow obstruction 3. A correlation between airway hyperresponsiveness and blood 4 or airway 5 eosinophilia has been reported. However, the relationship between eosinophilic inflammation and asthma severity is controversial. Indeed, some studies showed a correlation between sputum eosinophilia and asthma severity 6 whereas others did not 7.
Corticosteroids play a pivotal role in the treatment of the asthma 8–10. They rapidly reduce the number of eosinophils in the blood and tissues and inhibit their degranulation, suggesting that sputum eosinophilia could be a good predictor of response to inhaled corticosteroids 11. Moreover, asthmatic patients with eosinophilic inflammation seem to have a better response to inhaled corticosteroids than asthmatics with <3% of sputum eosinophils 12. Similarly, subjects with chronic obstructive pulmonary disease and a low sputum eosinophil count have a poorer response in terms of airway function following treatment with oral or inhaled corticosteroids than those with sputum eosinophilia 13. Since some mildly uncontrolled asthmatic patients show no sputum eosinophilic inflammation 14 this study questioned whether or not these subjects could benefit from corticosteroid treatment. Sputum examination provides a unique opportunity to follow eosinophil counts in asthmatic patients closely and reliably, and it can be repeated on several occasions to monitor the therapeutic effects of such medications as inhaled or oral corticosteroids 15, 16. In the present study, the prevalence of patients without sputum eosinophilia was investigated. The authors also examined whether percentage of sputum eosinophils was a predictor of short-term response to inhaled corticosteroids and they investigated whether neutrophil counts were increased in asthmatics without sputum eosinophilia compared with asthmatics with sputum eosinophilia.
Methods
Study design
Steroid-naive asthmatics were investigated at Sacré-Coeur Hospital, (Montreal, Qc, Canada) and Laval Hospital, (Sainte-Foy, Qc, Canada) on two occasions. On the first visit, spirometry, methacholine inhalation challenge, sputum induction and skin-prick tests were performed. Treatment with inhaled corticosteroids (250 µg fluticasone twice daily as Flovent Diskus®; GlaxoSmithKline, Mississauga, ON, Canada) was instituted for 1 month. One month later the same investigations were repeated and the compliance with treatment was checked by verifying the Diskus counter.
Subjects
Asthmatic adults were recruited through newspaper advertisements. They were included consecutively in the study regardless of their sputum eosinophil count. All subjects had suboptimal asthma control and complained of daily asthmatic symptoms, requiring daily rescue by β2 short-acting agonists and/or nocturnal awakenings. None of the patients had been treated with oral or inhaled corticosteroid for at least 3 months prior to the investigation. Asthma was diagnosed according to the current Guidelines for the Diagnosis and Management of Asthma 9. All subjects who had suffered an upper or lower respiratory infection within the 4 weeks prior to the first visit, and exsmokers or current smokers of >10 pack-yrs were excluded.
The study was approved by the participating hospitals' research ethics committees and all subjects provided informed written consent.
Procedures
Questionnaires were used to document subject characteristics and symptom severity graded on a validated 10-point Borg scale 17 and quality of life questionnaire 18. Spirometry was performed according to the American Thoracic Society standards 19. Methacholine challenge tests were performed as previously described 20. Sputum was induced using inhalations of increasing concentrations (3, 4 and 5%) of hypertonic saline 21 and processed as previously described 22. Allergy skin-prick tests with commercial extracts from common allergens were performed using the modified prick method; results were regarded as positive if the weal was ≥3 mm. Compliance with medication was checked by verifying the counters on the Flovent Diskus® inhalers used by the subjects during the study.
Analysis
Results were expressed as mean±sd, except for data with nonnormal distribution, which were expressed as median and interquartile range. Unpaired t-test and the Wilcoxon signed-rank test were used to compare provocative concentration causing a 20% fall in forced expiratory volume in one second (FEV1), (PC20) and cell counts, respectively, before and after treatment. The unpaired t-test was used to compare the normally distributed data between asthmatics with and without sputum eosinophilia, and the Mann-Whitney test was used to compare cell counts between these same groups. Correlations between sputum eosinophils, PC20 and FEV1 before and after treatment, as well as their difference between baseline and after treatment, were examined using Spearman's rank-order test. Subjects without sputum eosinophilia were defined a priori as subjects with sputum eosinophils ≤1%, which corresponds to the values of healthy subjects 23. However, the same calculations were also performed with an upper cut-off limit of 3% for sputum eosinophilia. Significance was accepted at the level of 95%.
Results
A total of 51 subjects met the inclusion criteria and were enrolled. Among them, 46 subjects completed the study. Five subjects were excluded; three because of the occurrence of a respiratory infection between the two visits and two because of noncompliance. Fourteen exsmokers and five current smokers were enrolled; they smoked 5.1±3 pack-yrs.
Of the 51 mildly uncontrolled asthmatic subjects who attended the first visit, 15 (29.4%) had a sputum eosinophil count ≤1%, and 23 (45.1%) had an eosinophil count ≤3%. Of the 46 subjects who completed the two visits, 12 (26%) had a sputum eosinophil count ≤1% at baseline and 21 (45.6%) had a sputum eosinophil count ≤3%.
Comparison between asthmatics with and without sputum eosinophilia
Baseline demographic, clinical and functional characteristics of the two groups (with and without sputum eosinophilia) were similar (tables 1⇓ and 2⇓) except for sputum eosinophil counts. After 1 month of treatment with inhaled corticosteroids, both groups had significant improvements in clinical (symptom score, quality of life) and functional (FEV1, PC20) parameters (table 2⇓). Similar results were obtained with a cut-off of 3% for sputum eosinophilia (table 3⇓). Subjects with sputum eosinophilia at baseline decreased their eosinophil count significantly after treatment.
This study was adequately powered (power=90%) to detect a minimum difference of 0.5 in logPC20 between both groups, which represents a 3.2-fold difference in PC20 with an α of 0.05. This difference represents the limit of reproducibility in the authors' centre and is considered to be clinically significant 24. However, this study was underpowered to show significant differences in FEV1 since it showed a power of 71% to detect a difference of 20% in FEV1 between both groups.
For the group of subjects with baseline sputum eosinophilia, a significant correlation was found between the percentage of sputum eosinophils at baseline and the improvement of FEV1 (correlation coefficient (rho)=0.52, p=0.002). A negative correlation between the changes in sputum eosinophils and FEV1 after treatment was also found (rho=−0.6, p<0.001; fig. 1⇓). There was no significant correlation between the change in PC20 after treatment and the percentage of eosinophils at baseline (rho=0.16, p=0.37), or the decrease in sputum eosinophils after treatment with inhaled corticosteroids (rho=−0.15, p=0.4; fig. 1⇓). There was no correlation between the changes in sputum eosinophils and the improvement of symptoms or quality of life.
Sputum neutrophils in asthmatics with and without sputum eosinophilia
Although the median sputum neutrophil counts were similar at baseline in the groups with and without sputum eosinophilia, there was a more marked reduction in median sputum neutrophils among the subjects without eosinophilia (−16.6 (42.9)%) than among subjects with sputum eosinophilia (−7.1 (27.4)%; p=0.05) after treatment. However, the reduction in absolute neutrophil count after inhaled corticosteroid treatment was not significantly different between the two groups. Four subjects without baseline sputum eosinophilia had a high sputum neutrophil count (>65%); two of these also had a high total cell count greater than 10×106 cells. However, they had no clinical evidence of respiratory infection. One of these subjects increased his eosinophil count from 0.3 to 5.5% after treatment with inhaled corticosteroids. There was no correlation found between sputum neutrophil count and clinical (symptom and quality of life score) or functional (FEV1 and PC20) parameters.
Discussion
In this study, it was found that 29% of 51 mildly uncontrolled steroid-naive asthmatics had a sputum eosinophil count <1%. After 1 month of treatment with inhaled corticosteroids, the respiratory symptoms and functional parameters of subjects without baseline sputum eosinophilia improved significantly.
Recently, Gibson et al. 25 found that among 56 asthmatics receiving high doses of inhaled corticosteroids, 59% had a sputum eosinophil count <2.5%. In this study, approximately the same proportion (45%) of steroid-naive subjects with a sputum eosinophil count of <3% were found.
The findings of this study differ from previous studies, which showed subjects without sputum eosinophilia did not improve as much as those with sputum eosinophilia after treatment with inhaled corticosteroids 12. The present study had a more stringent cut-off for sputum eosinophilia (1%) than previous studies (3%) 2. However, it is unlikely that the choice of cut-off explains the discrepancy as similar results have been obtained when the cut-off for sputum eosinophilia was set at 3%. The present study may have lacked power to identify differences in some indices such as FEV1 between the groups with and without sputum eosinophilia. Indeed, the primary outcome of this study was to evaluate the proportion of mildly uncontrolled steroid-naive asthmatic subjects who did not show sputum eosinophilia. The sample size was not calculated for demonstrating a significant difference in functional parameters such as FEV1 or PC20 between subjects with and without sputum eosinophilia as the number of subjects in each group could not be predicted. Nevertheless, the study was adequately powered (90%) to detect a clinically significant difference in airway responsiveness between the two groups and therefore it can be stated that the improvement of PC20 was similar in both groups. In subjects with baseline sputum eosinophils >1%, a positive correlation was shown between the baseline sputum eosinophil count and improvement in FEV1 after treatment with inhaled corticosteroids. This was found to be consistent with previous findings 12. However, there was no correlation between baseline sputum eosinophils and improvement of airway hyperresponsiveness. This observation suggests that eosinophilic airway inflammation may be responsible for or associated with a process leading to airflow limitation, but that it is not closely linked with airway responsiveness, which is consistent with previous findings 26. A greater improvement of FEV1 may have been detected in the group with sputum eosinophilia compared with the group without sputum eosinophilia in this study, if it had been powered to detect significant differences in FEV1 between the two groups.
It is possible that the subjects in this study without sputum eosinophil had higher eosinophil counts in their bronchial mucosa than in their bronchial lumen, as the correlation between sputum eosinophils and eosinophils in the bronchial mucosa has been found to be weak or absent 27, 28. It is also possible that some fluctuations in baseline sputum eosinophil counts occurred. However, it was shown previously that the reproducibility of the eosinophil count performed on two separate occasions within a 6-day period is good 22. It is therefore unlikely that the group without sputum eosinophilia had a high eosinophil count within the week of the first measurement.
It can be argued that this study did not include a placebo group and that the group of subjects without sputum eosinophilia would have improved even on placebo. Although this concern cannot be answered, it is unlikely that such a consistent and marked improvement in all clinical and functional parameters would have occurred in asthmatics treated with placebo. Moreover, although the placebo effect may have affected the pre- and post-treatment comparison, the effect is supposed to be similar in both groups and should not have interfered with the comparison between the two groups.
Gibson et al. 25 found that subjects with eosinophils <2.5% also had higher neutrophil counts. The subjects in this study, without sputum eosinophilia did not show higher neutrophil counts than subjects with sputum eosinophilia. This discrepancy may be explained by the absence of treatment with inhaled corticosteroids at baseline in the subjects in this study. Indeed, corticosteroids might induce neutrophilic inflammation by mechanisms such as the reduction of neutrophil apoptosis 29. It is possible, although not clinically evident, that some subjects with both a high neutrophil count and a high total cell count had a poor control of their asthma because of a respiratory infection. In these subjects, sputum eosinophilia may have been masked by the massive increase in neutrophils. Consistent with this hypothesis, two subjects increased their eosinophil count after inhaled corticosteroids. In these subjects, the decrease in neutrophil counts may have been due to the resolution of the infection.
Glucocorticoids inhibit eosinophil migration and degranulation but also suppress multiple components of allergic airway inflammation such as cell recruitment, vascular leakage and production of various cytokines (interleukin-2, 4, 5 and T-cell growth factor) 30. Therefore, it is not surprising that the absence of sputum eosinophilia itself fails to predict the effect of the treatment with inhaled corticosteroids in the subgroup without sputum eosinophilia.
In conclusion, it was found that a fair proportion (29%) of mildly uncontrolled steroid-naive asthmatics do not show sputum eosinophilia. Although asthmatic subjects with high eosinophil counts seem to have a larger improvement of their forced expiratory volume in one second after inhaled steroid treatment than subjects with low eosinophil counts, the absence of sputum eosinophils does not seem to be an indicator of a poor overall response to inhaled steroid treatment in these subjects. However, this question will only be fully answered by a double-blind, placebo-controlled trial comparing the response of symptomatic asthmatics without sputum eosinophilia after treatment with inhaled steroid, to their response after treatment with placebo.
Acknowledgments
The authors would like to thank S. Chaboillez, and J. Milot for their active participation in the study and L. Schubert for reviewing the manuscript.
Footnotes
-
↵ For editorial comments see page 1359.
- Received March 1, 2002.
- Accepted June 20, 2002.
- © ERS Journals Ltd