Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions

Occupational asthma caused by chloramines in indoor swimming-pool air

K.M. Thickett, J.S. McCoach, J.M. Gerber, S. Sadhra, P.S. Burge
European Respiratory Journal 2002 19: 827-832; DOI: 10.1183/09031936.02.00232802
K.M. Thickett
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.S. McCoach
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.M. Gerber
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S. Sadhra
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P.S. Burge
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The first series of three workers who developed occupational asthma following exposure to airborne chloramines in indoor chlorinated swimming pools is reported. Health problems of swimmers in indoor pools have traditionally been attributed to the chlorine in the water. Chlorine reacts with bodily proteins to form chloramines; the most volatile and prevalent in the air above swimming pools is nitrogen trichloride.

Two lifeguards and one swimming teacher with symptoms suggestive of occupational asthma kept 2-hourly measurements of peak expiratory flow at home and at work, analysed using the occupational asthma system (OASYS) plotter, and/or had specific bronchial challenge testing to nitrogen trichloride, or a workplace challenge.

Air measurement in one of the pools showed the nitrogen trichloride levels to be 0.1−0.57 mg·m−3, which was similar to other studies. Two workers had peak expiratory flow measurements showing occupational asthma (OASYS-2 scores 2.88 and 3.8), both had a positive specific challenge to nitrogen trichloride at 0.5 mg·m−3 with negative challenges to chlorine released from sodium hypochlorite. The third worker had a positive workplace challenge.

Swimming-pool asthma due to airborne nitrogen trichloride can occur in workers who do not enter the water because of this chloramine. The air above indoor swimming pools therefore needs to be assessed and managed as carefully as the water.

  • bronchial provocation test
  • nitrogen trichloride
  • occupational asthma
  • peak expiratory flow
  • swimming pool

Footnotes

  • © ERS Journals Ltd
View Full Text
PreviousNext
Back to top
View this article with LENS
Vol 19 Issue 5 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Occupational asthma caused by chloramines in indoor swimming-pool air
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Occupational asthma caused by chloramines in indoor swimming-pool air
K.M. Thickett, J.S. McCoach, J.M. Gerber, S. Sadhra, P.S. Burge
European Respiratory Journal May 2002, 19 (5) 827-832; DOI: 10.1183/09031936.02.00232802

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Occupational asthma caused by chloramines in indoor swimming-pool air
K.M. Thickett, J.S. McCoach, J.M. Gerber, S. Sadhra, P.S. Burge
European Respiratory Journal May 2002, 19 (5) 827-832; DOI: 10.1183/09031936.02.00232802
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Methods
    • Results
    • Discussion
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Occupational and environmental risk factors for respiratory symptoms in rural Beijing, China
  • Exhaled nitric oxide in specific challenge tests to assess occupational asthma
  • Does negative expiratory pressure influence performances of spirometry in older patients?
Show more Original Articles: Occupation/Environment

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2022 by the European Respiratory Society