Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • ERS Guidelines
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Subscriptions

Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability

V. Giraud, N. Roche
European Respiratory Journal 2002 19: 246-251; DOI: 10.1183/09031936.02.00218402
V. Giraud
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
N. Roche
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

This study assessed whether the improper use of pressurized metered-dose inhalers (pMDIs) is associated with decreased asthma control in asthmatics treated by inhaled corticosteroids (ICS).

General practitioners (GPs) included consecutive asthmatic outpatients treated by pMDI-administered ICS and on-demand, short-acting β2-agonists. They measured an asthma instability score (AIS) based on daytime and nocturnal symptoms, exercise-induced dyspnoea, β2-agonist usage, emergency-care visits and global perception of asthma control within the preceding month; the inhalation technique of the patient also was assessed.

GPs (n=915) included 4,078 adult asthmatics; 3,955 questionnaires were evaluable. pMDI was misused by 71% of patients, of which 47% was due to poor coordination. Asthma was less stable in pMDI misusers than in good users (AIS: 3.93 versus 2.86, p<0.001). Among misusers, asthma was less stable in poor coordinators (AIS: 4.38 versus 3.56 in good coordinators, p<0.001).

To conclude, misuse of pressurized metered-dose inhalers, which is mainly due to poor coordination, is frequent and associated with poorer asthma control in inhaled corticosteroid-treated asthmatics. This study highlights the importance of evaluating inhalation technique and providing appropriate education in all patients, especially before increasing inhaled corticosteroid dosage or adding other agents. The use of devices which alleviate coordination problems should be reinforced in pressurized metered-dose inhaler misusers.

  • asthma control
  • inhaled corticosteroids
  • metered-dose inhaler
  • misuse
  • poor coordination

This work was supported in part by a grant from 3M Pharma, Cergy, France.

Asthma-related morbidity and costs remain high despite significant advances in the understanding, management and treatment of the disease. This may be due to several factors including increased asthma incidence, changes in environmental triggers, nonadherence of physicians to guidelines, noncompliance of patients, or failure of effective medications to reach their target at sufficient concentration because of misuse of inhalation devices. Indeed, inhalation remains the main route of administration for asthma therapy, since it allows drugs to reach high bronchial concentrations with low systemic bioavailability 1. This is especially important for corticosteroids, which are the most effective maintenance therapy in asthma care 2.

Due to their high cost-effectiveness ratio 3, pressurized metered-dose inhalers (pMDIs) are the most commonly used inhalation devices. However, a number of surveys suggest that pMDIs are frequently misused: according to a review of 21 studies, the frequency of misuse ranges from 14–90%, with an estimated average of 50% 4, 5. Misuse decreases lung deposition from 20% to 7% 6; Lindgren et al. 7 showed that the increase in forced expiratory volume in one second (FEV1) after inhalation of a short-acting β2-agonist decreased by 30% in patients making inhalation errors, as compared to good pMDI users. When the drug used is an inhaled corticosteroid (ICS), the consequences of inhaler misuse have not been assessed and are less easily recognizable, since the expected benefits are not immediate and the disease is highly variable.

The present study was designed to determine if pMDI misuse is associated with increased asthma instability (as a marker of decreased corticosteroids efficacy) in patients treated with ICS.

Patients and methods

Subjects

General practitioners (GPs, n=915) were asked to include all consecutive consenting adult asthmatics (aged >15 yrs) who visited them, and had been treated for at least 3 months by regular ICS (500–1500 µg·day−1) and on-demand short-acting β2-agonists, both administered by pMDI without holding chamber. The diagnosis of asthma had to be based on the operational definition provided by international guidelines 2. Exclusion criteria were concomitant treatments within the previous 3 months with long-acting β2-agonists, long-term oral corticosteroids, β-blocking agents (eye-drops or by oral route) and theophylline.

Data collection

Patients answered a short questionnaire assessing their beliefs about their own inhalation technique, previous demonstration and assessment of inhalation technique, and perception of the suitability and efficacy of the inhalation device. Then, the physician completed a questionnaire on asthma instability within the previous month (table 1⇓) and recorded the highest value of three peak expiratory flow rate (PEFR) measurements. Finally, patients were requested to take a puff of their usual short-acting β2-agonist with their usual inhalation technique, which was observed and rated by the GP according to prespecified items (table 2⇓). GPs had been previously taught by trained clinical research assistants on how to assess inhalation technique according to these items.

View this table:
  • View inline
  • View popup
Table 1—

Asthma instability score

View this table:
  • View inline
  • View popup
Table 2—

Causes of metered-dose inhaler misuse

Asthma instability

An asthma instability score (AIS) was used which was developed by a panel of 11 experts (see Acknowledgement). Six items were selected because they were: 1) widely recommended and used for this purpose and 2) easy to collect in general practice. These items were: 1) daytime respiratory symptoms (chest discomfort, dyspnoea, cough, and wheezing); 2) asthma-related nocturnal awakenings; 3) exercise-induced asthma; 4) β2-agonist usage; 5) serious exacerbations (i.e. requiring emergency medical intervention) and 6) global assessment by the GP of the evolution during the previous month. Then the panel determined the scoring range for each item, with the aim of detecting a clinically-significant difference for each one-point change. As indicated in table 1⇑, this scoring system allowed the calculation of the global AIS, which could range from zero (best) to nine (worst).

Patient's inhalation technique

Inhalation technique was rated according to seven omissions and five errors (table 2⇑) 1, 7–9. Patients were classified as “misusers” if at least one error or omission was made. A subgroup of misusers was defined according to coordination between actuation and inhalation. Coordination was classified as “poor” if at least one of three potential errors was made (inspiration by nose, actuation at the end of inspiration, no inspiration) and/or if the device was not actuated at the beginning of inspiration.

Statistical analysis

Comparisons of quantitative variables (i.e. age, AIS and PEFR) between groups (i.e. between good users and poor users with and without poor coordination, and between educated and noneducated patients) were performed using a bilateral t-test for comparison of means. The sensitivity of the results to separate removal of each item of the AIS was studied and the relationship between each potential error or omission in inhalation technique and AIS was assessed. Categorical variables (i.e. sex, age range, and cause of medical visit) were compared between the groups studied, using table analysis by Pearson's Chi-squared test 10. Correlations between quantitative variables (i.e. between AIS and PEFR, and between AIS and age) were studied by linear regression analysis. Values of p<0.05 were considered statistically significant. Data are reported as mean±sem unless otherwise indicated.

Results

Of the 4,198 questionnaires completed, 120 (2.8%) were excluded from analysis because of patient's ineligibility (age <15 yrs in five patients, recent use of long-acting β2-agonists in 115). In the remaining population (n=4,078), 2,179 were males (54%) and 1,869 were females (46%), with a mean age of 46.3±19.3 yrs. PEFR was available in 3,055 patients (75% of eligible subjects), with a mean value of 382±106.8 L·min−1 (range: 105–800), i.e. 72.8±19.0% of predicted. The cause leading the patient to seek medical advice was first visit in 102 cases (3%), routine scheduled visit in 2,932 cases (70%), asthma worsening in 789 cases (20%) and an acute exacerbation in 149 cases (4%). Short-acting β2-agonists had been taken within 4 h prior to the visit by 38% of patients.

Pressurized metered-dose inhaler misuse

Of the 3,955 patients in whom all corresponding items were documented (97% of the eligible population), 2,791 (71%) were considered as poor users; among them 1,320 (33%) were poor coordinators (corresponding to 47% of poor users). Among misusers, 78% made >1 error or omission in inhalation technique. Only 15% of poor users and 23% of poor coordinators self-rated their technique of inhalation as “poor” or “very poor”. Causes of poor inhalation technique are given in table 2⇑. The frequency of pMDI misuse increased with age and was 61.0% between 15–30 yrs, 70.0% between 30–60 yrs, 77.2% between 60–75 yrs, and 85.9% in patients >75 yrs (p<0.00001). There was no difference in the frequency of misuse between males and females (69.4 versus 72.0%, respectively; p=ns), although the frequency of poor coordination was slightly higher in females (35.9 versus 30.4% in males, p=0.0002).

Effect of prior education on inhalation technique and asthma instability

Before the visit, 84% of patients had been shown how to use their inhaler and inhalation technique had been checked in 68%. Misuse was less frequent in subjects in whom these two steps of education had been performed (66.5% versus 86.4% in subjects who received no education; p<0.0001). There was no difference between educated and noneducated patients in terms of AIS (3.73±0.11 versus 3.61±0.05; p=0.41) but PEFR was slightly but significantly lower in noneducated patients (70.4±0.4 versus 72.9±1.0; p=0.02). Worsened asthma condition was a more frequent cause of medical visit (3.3 versus 6.2%; p=0.005) in noneducated patients.

Relationship between pressurized metered-dose inhaler misuse, cause of medical visit and asthma instability

PEFR correlated to AIS (r=0.33, p<0.00001) and was lower in misusers (71.6±0.4% of predicted) and poor coordinators (70.1±0.6%) than in good users (75.5±0.6%, p<0.0001 for each comparison). The cause of medical visit in good users and misusers without and with poor coordination is given in table 3⇓. Medical visits for worsened asthma condition or emergency visits were more frequent in misusers with poor coordination, than in misusers without poor coordination or good users (p<0.00001).

View this table:
  • View inline
  • View popup
Table 3—

Cause of medical visit, β2-agonist usage, recent evolution of asthma and emergency care visit during the previous month according to inhalation technique and coordination

AIS and evaluation of inhalation technique were both available in 3,709 patients (91% of the eligible population). The distribution of the AIS in good users and misusers with and without poor coordination is given in figure 1⇓. The mean AIS was higher in misusers than in good users and, among misusers, the mean AIS was higher in poor coordinators (table 4⇓). In misusers as compared to good users, and in misusers with poor coordination as compared to misusers without poor coordination, the greater instability of asthma was reflected, in particular, by more frequent β2-agonist use, recent worsening of asthma and occurrence of serious exacerbations (table 3⇑, p<0.01 for all comparisons).

Fig. 1.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.—

Distribution of asthma instability score (AIS) according to inhalation technique and coordination. □: misusers, poor coordinators; Embedded Image: misusers, good coordinators; Embedded Image: good users. n=3709 (91% of the eligible population). Analysis of variance: p<0.0001.

View this table:
  • View inline
  • View popup
Table 4—

Mean asthma instability score according to inhalation technique and coordination

There were significant differences in AIS according to the presence or absence of each single error or omission in inhalation technique (p=0.03 for cap removal and p<0.00001 for all others). Linear regression analysis showed that the number of errors in inhalation technique, as described in figure 2⇓, correlated to the AIS (r=0.3, p<0.0001). According to stepwise analysis, errors or omissions that independently correlated to the AIS, were upside-down metered-dose inhaler holding, forced expiration prior to inhalation, inappropriate timing of device actuation including actuation at the end of inspiration, too high inspiratory flow rate, incomplete inspiration, double actuation and lack of apnoea following inspiration.

Fig. 2.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.—

Frequency distribution of the number of errors or omissions in inhalation technique (left axis: Embedded Image) and relationship between this number and AIS (mean±SEM, right axis: Embedded Image). Correlation between number of errors and AIS (linear regression analysis): r=0.3, p<0.0001.

Sensitivity of the results to changes in asthma instability score items

Separate removal of each individual item of the AIS did not affect the relationship between this score and inhaler misuse with or without poor coordination (t-tests, p<0.0001 for all comparisons). Similarly, it did not alter the correlation of this score with PEFR (p<0.0001 for all regression analyses). Each single item of the AIS was influenced by misuse and especially poor coordination (p<0.0001 for all comparisons).

Discussion

In adult asthmatic patients treated with ICS and visiting their GP, the proportion of pMDI misusers was high and increased with age. Misuse and more specifically poor coordination were strongly associated with asthma instability. This suggests that the decrease in lung deposition which is associated with pMDI misuse reduces the clinical efficacy of ICS and impairs asthma control.

Several points have to be considered when interpreting the results. Firstly, participating GPs were volunteers, so that their interest in asthma might have induced a better knowledge of inhalation devices and a better education of their patients. Similarly, patients had to give their consent before participation in the study, which may influence the frequency of pMDI misuse. However, these potential bias would have led to underestimation of the frequency of pMDI misuse. This frequency was high (71%) but very similar to what has been found in other studies 4, 11–14. Indeed, this study is, to the best of the authors' knowledge, the largest to assess the frequency of pMDI misuse.

Secondly, potential confounding factors were not considered, such as baseline disease severity, poor compliance, insufficient asthma treatment including inadequate ICS dosage, diagnostic errors, comorbid heart or respiratory illnesses, poor control of environmental triggers such as allergen exposure. However, the large size of the studied sample and the magnitude and consistency of the difference in asthma instability between pMDI misusers and good users make it unlikely that these differences were due only to confounding factors; in addition, all AIS items were influenced by misuse and especially poor coordination, and the relationship between misuse, poor coordination and AIS was insensitive to separate removal of each single item of the AIS: this suggests that misuse and especially poor coordination are very important factors for asthma control.

Greater asthma instability in patients treated by ICS and showing poor use of their inhaler might be explained by a direct mechanism (the failure of medication to reach the bronchi at adequate concentration) as well as an indirect one (lower compliance due to decreased efficacy). Such a vicious circle is quite classical with treatments of chronic diseases requiring a strict compliance: breaking it down is of utmost importance in a potentially fatal and resource-consuming disease such as asthma. Compliance could not be reliably assessed in this study since it was cross-sectional; prospective trials will be required to study its relationship with misuse.

The strict criteria used to define good use of pMDIs may partly account for the high frequency of misuse, however, these criteria are based on data from scintigraphic deposition studies 6, 8, 9, and, as outlined earlier, a figure of 71% remains within the range found by other sources 4, 11–14. In addition, only a low proportion of misusers (22%) had only one error or omission and each single error was associated with asthma instability, which increased with the number of errors. The high frequency of poor coordination (47%) among possible causes of misuse is also in accordance with the results of previous surveys 4, as is the increase in misuse with age 12, 15. The association between poor coordination and worse asthma control in misusers suggests that one of the first aims of research on inhalation devices should be to alleviate coordination problems.

The impact of improper pMDI usage on the lung deposition of inhaled agents has been clearly demonstrated in numerous well-designed studies. Altogether, these studies found a 50–66% reduction in lung deposition in pMDI misusers 6, 8, 16. The clinical consequences of this decrease in lung deposition have been easy to demonstrate with bronchodilators, since an immediate indicator of drug effect does exist and is easy to measure (i.e., the magnitude of bronchodilation, which decreases by 30% with pMDI misuse) 7.

The picture is more complicated when the treatment targets a long-term effect and when the disease is intrinsically variable. In the present study, asthma instability was proposed as a potential indicator of the hazards of faulty inhaler technique. Because asthma can be severe but controlled, or moderate but unstable (depending on the adequacy of administered treatments) 2, 17, assessing instability appeared more relevant than assessing severity. The authors developed the AIS since there was no generally accepted and validated measure for asthma instability at the time of the current study. Although this score allowed the demonstration, for the first time, of a relationship between corticosteroid pMDI misuse and poor asthma control, the significance of this result could be questioned, since the AIS had not been formally validated before its use in this study. However, this score was developed by an expert panel using items which were widely recommended and used for assessment of asthma control, and which were all influenced by misuse and poor coordination; three out of six of the AIS items were used to define asthma control in the study by Reddel et al. 18, and four are part of the six-item asthma control questionnaire (ACQ) which has recently been transversally and longitudinally validated by Juniper et al. 19 in 50 patients. AIS items that are not included in the ACQ are emergency-care visits and global assessment of evolution by the patient. Conversely, ACQ but not AIS includes wheezing and FEV1. Other main differences between the AIS and the ACQ are the duration of retrospective assessment (1 week for the ACQ and 1 month for the AIS) and the way of scoring each item (six-point scales for the ACQ, two or three-point scales for the AIS). Although not formally tested, the discriminant properties of the AIS are suggested by its correlation with PEFR, which was highly significant although of low magnitude, as could be expected in ICS-treated patients. If this score was to be used in longitudinal studies, its responsiveness to change should be determined.

Finally, a one-point mean difference in AIS was found between good and poor users, corresponding to 11% of the maximal total AIS (i.e. nine points). Interestingly, the difference in variation of the ACQ between stable and unstable patients found by Juniper et al. 19 was 0.72, corresponding to 12% of the maximal total ACQ (i.e. six points). This suggests that a one-point difference in the AIS is indeed of clinical significance.

Fewer misusers than good users had received education on inhalation technique, which suggests that education is effective at improving inhaler technique. However, there was no significant direct relationship between education and AIS, which is most likely due to the fact that education is not always successful (errors are corrected in only 50% of poor users, 50% of whom return to their “bad habits” within a few weeks), and that misuse is obviously not the only factor that influences asthma control.

Another striking finding was the lack of awareness in poor users of their difficulties with pMDI inhalation technique, only 15% rating their pMDI use as “poor” or “very poor”. As emphasized by others 20, this highlights the need for progress in asthmatics' education and about the correct use of inhalers.

To conclude, it is clearly important to evaluate patient inhalation technique, and especially coordination errors, before increasing inhaled corticosteroids dosage or adding long-acting β2-agonists in patients in whom asthma is poorly controlled. Use of devices that make inhalation technique easier, such as holding chambers, breath-actuated devices and dry-powder inhalers should be reinforced in pressurized metered-dose inhaler misusers. This strategy, which is already recommended by international guidelines on asthma, should be more extensively implemented to limit the cost and side-effects of unnecessary additional treatments. The beneficial effect of improvement in inhalation technique or change in inhalation device, on asthma control, now needs to be demonstrated in prospective trials.

Acknowledgments

The authors wish to thank P. Chanez, B. Crestani, R. Dubost, A. Magnan, M. Murris-Espin, C. Pannelier, M. Pérol, T. Perez, O. Sitbon, C. Thiriet, M. Tunon de Lara for their help in designing the asthma instability score or organizing data collection.

  • Received February 22, 2001.
  • Accepted August 9, 2001.
  • © ERS Journals Ltd

References

  1. ↵
    Roche N, Chinet T, Huchon G. Ambulatory inhalation therapy in obstructive lung diseases. Respiration 1997;64:121–130.
    OpenUrlPubMedWeb of Science
  2. ↵
    National Institutes of Health, National Heart, Lung and Blood Institute. Global Initiative for Asthma; Global strategy for asthma management and prevention; NHLBI/WHO workshop report. National Institutes of Health, Bethesda, MD, USA, 1995. Publication No. 95–3659: 1–176.
  3. ↵
    Levy ML. Metered dose inhalers: current and future uses. Br J Clin Pract 1997;89:16–21.
    OpenUrl
  4. ↵
    Chinet T, Huchon G. Misuse of pressurized metered-dose aerosols in the treatment of bronchial diseases. Incidence and clinical consequences. Ann Med Interne 1994;145:119–124.
    OpenUrlPubMed
  5. ↵
    Hanania NA, Wittman R, Kesten S, Chapman KR. Medical personnel's knowledge of and ability to use inhaling devices. Metered-dose inhalers, spacing chambers, and breath-actuated dry powder inhalers. Chest 1994;105:111–116.
    OpenUrlCrossRefPubMedWeb of Science
  6. ↵
    Newman SP, Weisz AW, Talaee N, Clarke SW. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique. Thorax 1991;46:712–716.
    OpenUrlAbstract/FREE Full Text
  7. ↵
    Lindgren S, Bake B, Larsson S. Clinical consequences of inadequate inhalation technique in asthma therapy. Eur J Respir Dis 1987;70:93–98.
    OpenUrlPubMedWeb of Science
  8. ↵
    Newman SP, Pavia D, Garland N, Clarke SW. Effects of various inhalation modes on the deposition of radioactive pressurized aerosols. Eur J Respir Dis 1982;119:Suppl. 63, 57–65.
    OpenUrl
  9. ↵
    Newman SP, Pavia D, Clarke SW. How should a pressurized beta-adrenergic bronchodilator be inhaled? Eur J Respir Dis 1981;62:3–21.
    OpenUrlPubMedWeb of Science
  10. ↵
    Zar JH. Biostatistical analysis. Engleton Cliffs, Prentice Hall, Inc., 1983.
  11. ↵
    Liard R, Zureik M, Aubier M, Korobaeff M, Henry C, Neukirch F. Misuse of pressurized metered dose inhalers by asthmatic patients treated in French private practice. Rev Epidemiol Sante Publique 1995;43:242–249.
    OpenUrlPubMedWeb of Science
  12. ↵
    Goodman DE, Israel E, Rosenberg M, Johnston R, Weiss ST, Drazen JM. The influence of age, diagnosis, and gender on proper use of metered-dose inhalers. Am J Respir Crit Care Med 1994;150:1256–1261.
    OpenUrlPubMedWeb of Science
  13. Thompson J, Irvine T, Grathwohl K, Roth B. Misuse of metered-dose inhalers in hospitalized patients. Chest 1994;105:715–717.
    OpenUrlPubMedWeb of Science
  14. ↵
    Crompton GK. The patient's difficulties with inhalers. Lung 1990;168:658–662.
    OpenUrlCrossRefPubMedWeb of Science
  15. ↵
    Armitage JM, Williams SJ. Inhaler technique in the elderly. Age Aging 1988;17:275–278.
    OpenUrlFREE Full Text
  16. ↵
    Newman SP, Millar AB, Lennard-Jones TR, Moren F, Clarke SW. Improvement of pressurised aerosol deposition with Nebuhaler spacer device. Thorax 1984;39:935–941.
    OpenUrlAbstract/FREE Full Text
  17. ↵
    Cockroft DW, Swystun VA. Asthma control versus asthma severity. J Allergy Clin Immunol 1996;98:1016–1018.
    OpenUrlCrossRefPubMedWeb of Science
  18. ↵
    Reddel H, Ware S, Marks G, Salome C, Jenkins C, Woolcock A. Differences between asthma exacerbations and poor asthma control. Lancet 1999;353:364–369.
    OpenUrlCrossRefPubMedWeb of Science
  19. ↵
    Juniper EF, O'Byrne PM, Guyatt GH, Ferrie PJ, King DR. Development and validation of a questionnaire to measure asthma control. Eur Respir J 1999;14:902–907.
    OpenUrlAbstract/FREE Full Text
  20. ↵
    McFadden ER. Improper patient technique with metered-dose inhalers: clinical consequences and solutions to misuse. J Allergy Clin Immunol 1995;96:278–283.
    OpenUrlCrossRefPubMedWeb of Science
View Abstract
PreviousNext
Back to top
View this article with LENS
Vol 19 Issue 2 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
V. Giraud, N. Roche
European Respiratory Journal Feb 2002, 19 (2) 246-251; DOI: 10.1183/09031936.02.00218402

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
V. Giraud, N. Roche
European Respiratory Journal Feb 2002, 19 (2) 246-251; DOI: 10.1183/09031936.02.00218402
Reddit logo Technorati logo Twitter logo Connotea logo Facebook logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Patients and methods
    • Results
    • Discussion
    • Acknowledgments
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Variability in the prevalence of premenstrual asthma
  • Parental occupation is a risk factor for childhood wheeze and asthma
  • Aerobic training reverses airway inflammation and remodelling in an asthma murine model
Show more Original Articles: Asthma

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society