Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions

Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome

P. Lloberes, G. Sampol, G. Levy, D. Aristizabal, T. Sagales, M. De la Calzada, A. Roca, I. Cañas, F. Morell
European Respiratory Journal 2001 18: 530-534; DOI: 10.1183/09031936.01.00072401
P. Lloberes
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G. Sampol
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G. Levy
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D. Aristizabal
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Sagales
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. De la Calzada
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Roca
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
I. Cañas
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
F. Morell
1Servei de Pneumologia i, 2Servei de Neurofisiologia Clinica, Hospital General Vall d'Hebron, Barcelona, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The high demand for full polysomnography and the better quality of sleep at home are the main reasons for performing home sleep studies. Home respiratory monitoring has been evaluated in several studies, but the influence of setting on the results of unattended respiratory monitoring has not been assessed to date.

Unattended monitoring of respiratory variables at home and in the sleep laboratory was conducted in 35 consecutive patients with suspected sleep apnoea/hypopnoea syndrome. Respiratory variables during sleep, rate of successful studies and patient preference were compared.

The data acquisition failure rate was 2.8% in the sleep laboratory and 5.7% at home. The mean difference between apnoea/hypopnoea indices (AHI) obtained from home and laboratory studies was −0.21±8 (95% confidence interval 3.27–2.84). Using the method comparison approach of Bland and Altman, the limits of agreement of the mean difference between AHI home and AHI laboratory were −16.7 and 17.1. No difference was observed between the studies in time spent in different body positions. When patients were asked where they would prefer to repeat the sleep study, 53% replied at home, 28% in hospital and 19% showed no preference.

It was concluded that the setting of unattended respiratory monitoring (home or sleep laboratory) influences neither the number of valid studies nor the results of the respiratory parameters measured; most patients, however, preferred home studies.

  • ambulatory monitoring
  • respiratory variables
  • sleep apnoea/hypopnoea syndrome
  • unattended monitoring

Sleep apnoea/hypopnoea syndrome (SAHS) is a very common condition 1, 2. Douglas et al. 3 showed that recording sleep electrophysiologically was of no diagnostic value in SAHS as the condition can be as accurately defined by apnoeas plus hypopnoeas per time in bed as per time asleep. These findings have been supported by the results of many studies comparing monitoring of respiratory variables with polysomnography (PSG), even in an unattended setting 4–. PSG is indicated when a discrepancy exists between clinical symptoms and negative results of respiratory monitoring or when other diseases causing daytime sleepiness are suspected. The number of patients requiring assessment of possible SAHS has led to long waiting lists in many sleep laboratories, and attention is increasingly focused on domiciliary sleep studies 9, 10, 12, 13, 15, 16, 18, 19. To the authors' knowledge, home unattended respiratory monitoring has exclusively been compared with full PSG and, in some cases, to the same portable equipment used simultaneously with PSG in the sleep laboratory. Owing to the high demand for full PSG studies in the sleep laboratory, the authors began to perform unattended respiratory monitoring of sleep, both in the laboratory and at home. In order to assess the influence of setting on the results of the studies, home and laboratory unattended monitoring of respiratory variables during sleep were compared in terms of the number of technically successful studies, home versus laboratory variability and patient preference.

Material and methods

Study subjects

Exclusion criteria for participation in the study were: residence outside the metropolitan area of Barcelona (>30-min drive), shift work, lack of transportation facilities, symptoms suggesting narcolepsy or periodic leg movement disorder, or psycho-physical handicap hindering performance of the home study. The study population consisted of 35 consecutive patients referred to the outpatient sleep clinic for clinically-suspected SAHS.

Study design

The study was performed prospectively with each patient undergoing two studies of respiratory variables during sleep on consecutive nights; the order (sleep laboratory and home) was randomized. A power calculation showed that 35 patients would be required, based on the following assumptions: a difference in apnoea/hypopnoea index (AHI) of 10±20 21, a failure rate of 10% and a statistical power ≥80% at a significance level of 5%. The protocol was consistent with the principles of the Declaration of Helsinki 22. Studies without 4 h of interpretable recording were regarded as technically unsatisfactory and ruled out. The minimum signals required to define an interpretable recording were oronasal flow, oximetry and one of the thoracic or abdominal bands.

Variables analysed from the respiratory recordings were: time of recording, AHI, mean and nadir arterial oxygen saturation (Sa,O2), cumulative percentage of time with Sa,O2 <90% and percentage of time in different body positions (supine or lateral). After the performance of both studies, patients were required to answer a questionnaire on self-perception of sleep quality, subjective number of hours slept, number of awakenings and where they would prefer to have the study repeated.

Methods

The respiratory monitor used was Sibel-Home 300 (Sibel SA, Barcelona, Spain) which records nasal airflow using thermistors, respiratory effort (chest and abdomen gauges), snoring (microphone), body position and finger pulse-oximetry. The device had been validated with full PSG 20. Both home and laboratory recordings were transferred to a computer by a technician the following morning and stored on the hard disk until analysis. The duration of each recording was used for analysis. The same physician scored the studies manually and was unaware of the patient's name or where the recording was performed. Apnoeas were defined as absence of oronasal airflow for ≥10 s and hypopnoeas as a discernible reduction in airflow for ≥10 s followed by a ≥3% reduction in Sa,O2. The AHI was obtained by dividing the number of apnoeas plus hypopnoeas by the time of recording. SAHS was defined on the basis of an AHI >10 in the presence of at least two of the following clinical symptoms: snoring, witnessed apnoeas, nocturnal choking, nocturia, morning headaches, daytime somnolence and tiredness. These symptoms were evaluated by the physician in charge of the patients at an initial visit prior to the night study.

With respect to home studies, after arriving at the sleep laboratory at 20:00 h, patients were instructed in the use of the unattended device for ∼30 min. A nurse placed bands on each patient's chest and abdomen and the microphone on the suprasternal notch, and explained how to position the thermistor and the pulse-oximeter. Patients took the monitor home in a bag and were told to switch it on upon going to bed, switch it off upon awakening and return it to the sleep laboratory the following morning.

Regarding sleep laboratory studies, the same nurse placed the sensors on the patients, switched on the monitoring device at 22:00 h and switched it off at ∼06:30 h. Both studies were unattended.

Data analysis

Agreement between the AHI obtained from home and sleep laboratory studies was assessed by the method of Bland and Altman 23. Values were quoted as mean±sd and the significance of differences between means was assessed by a two-tailed t-test. Category comparisons were made with the Chi-squared test. Pearson correlations between home and sleep laboratory AHI and home and laboratory 3% desaturation rate were obtained.

Results

The mean age of the patients was 55.5±11.7 yrs and mean body mass index was 29.1±3.1 kg·m−2. Two cases were lost due to failure in acquisition of the airflow signal (one at home, one in the laboratory) and one due to fuse failure at home. Thus, the failure rate was 2.8% at the laboratory and 5.7% at home. The overall failure rate was 8.57% (95% confidence interval (CI) 1.80–23.06). Thirty-two patients had interpretable recordings in both home and sleep laboratory studies and were suitable for subsequent analysis (91.5%).

The results of home and sleep laboratory studies showed no significant differences in any of the parameters studied except in the duration of recording, which was significantly higher in the sleep laboratory compared with home studies (8.7±0.9 and 7.7±0.7 h, respectively, p<0.0001) (table 1⇓). No significant differences were observed between mean AHI from home and laboratory studies. The mean difference between home AHI and laboratory AHI was −0.21±8.47 (95% CI of the mean difference −3.27–2.84; limits of agreement −16.7–17.1) (fig. 1⇓). A highly significant correlation was found between AHI obtained from both studies (r=0.97, p<0.001) and between 3% Sa,O2 desaturation index (r=0.95, p<0.01, fig. 2⇓).

Fig. 1.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.—

Difference between apnoea/hypopnoea index (AHI) in home and laboratory recordings (diff AHI) plotted against their mean (mean AHI). ––––––: the mean difference between both measurements; – – – –: the limits of agreement of the mean difference.

Fig. 2.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.—

Correlation between 3% desaturation index recorded at home (DI home) and in the laboratory (DI lab).

View this table:
  • View inline
  • View popup
Table 1—

Respiratory parameters from unattended respiratory monitoring performed at home and in the sleep laboratory

Table 2⇓ shows the patients' self-reports of quality of sleep during both studies. No significant differences were found among the parameters studied when comparing both unattended studies. As shown, the proportions of patients having subjectively slept well, neither well nor badly, or badly were similar. The subjective estimation of time slept at home and in the laboratory was also similar (5.6±1.5 and 5.5±1.6, respectively). When patients were asked where they would repeat the sleep study, 17 replied at home (53%), nine (28%) at the hospital and six (19%) had no preference.

View this table:
  • View inline
  • View popup
Table 2—

Subjective evaluation of sleep quality at home and in the sleep laboratory

Discussion

The present study yielded three main results. First, unattended recording of respiratory variables during sleep proved to be an efficient procedure both at home and in the sleep laboratory, with an acceptable failure rate. Secondly, the parameters recorded in the laboratory and at home showed no significant differences and, therefore, no significant influence of the setting on the results. Thirdly, more than half the patients stated they would rather repeat the study at home than in the sleep laboratory.

Numerous studies have been published on the efficacy of home sleep studies 9, 10, 12, 13, 15, 16, 18, 19, but none compared the same portable monitoring system in an unattended way at home and in the sleep laboratory. Most ambulatory devices have been tested in a laboratory setting with simultaneous attended full PSG monitoring rather than unattended as in the home setting. The present study's protocol permitted assessment of the performance of the equipment both in the home and the laboratory, thereby avoiding the confounding effects of a simultaneous montage, which is uncomfortable for the patient. Flemons and Remmers 18 found a systematic bias between home and laboratory studies using the “Snore Sat” device. The home Snore Sat respiratory disturbance index (Ssat RDI) was lower than the simultaneous RDI (Ssat) or AHI (full PSG) performed at the sleep laboratory. The mean difference between simultaneous Ssat RDI and home Ssat RDI was 9.3 (limits of agreement 40.8 and −22.2). The authors believed that the difference between home and laboratory RDI probably depended on body position, and possibly less sleep disruption at home, resulting in fewer sleep onset hypopnoeas. A better agreement was found between home and laboratory AHI when both studies were unattended (mean difference −0.21±8.47 (95% CI −3.27–2.84) and no difference in the percentages of time in different body positions. In contrast, during full PSG in the sleep laboratory, patients usually spent more time in the supine position than they did at home, as demonstrated by Ballester et al. 24 and suggested by Flemons and Remmers 18. Parra et al. 19 studied the validity of a portable monitor of respiratory variables used in a home setting for the diagnosis of SAHS. In 50 and 39 patients respectively, the portable monitor was set-up with and without a technician's help. Although 10% of studies with an individual set-up required repeating, both of the domiciliary modalities (with and without a technician's intervention) were three times more cost-effective than full PSG. It was found that laboratory readings were significantly longer than home studies. In fact, in laboratory studies, recordings began at 22:00 h and were stopped at 06.30 h due to staff time schedules, while at home, patients switched the device on and off at will, resulting in a shorter recording time. The patients' self-perception of time asleep was significantly less than the actual recorded time. This could imply that the AHI obtained from recording time, not from sleeping time, underestimates the true AHI. However, when comparing subjective and polysomnographically determined sleep in SAHS patients, McCall et al. 25 reported that patients underestimate the time of sleep. In addition, Douglas et al. 3 showed that SAHS can be as accurately defined by apnoeas+hypopnoeas per time in bed as per time asleep.

Portable unattended recording devices are potentially subject to data loss or distortion because of equipment malfunction, sensor disconnection, technologist error, patient or family error or interference, power surges or loss, damage in transit, phone line interference during modem transfer, and error during playback. In the present study, three cases were lost due to failure in data acquisition (human failure in two cases and fuse failure in one). The failure rate was 2.8% and 5.7% for laboratory and home studies, respectively. The authors believe that the fuse failure at home may also have occurred in the laboratory, and thus, the failure rate could be considered equal in the two settings. Overall, a failure rate of 8.5% was obtained, similar to that described by Parra et al. 19 and less than that reported by Ancoli-Israel et al. 12. Redline et al. 26 reported a 5.3% failure rate when performing unattended full PSG at home, although the set-up of the equipment was made during an evening home visit by a technician.

Another interesting observation was patient preference, if a repeat study was necessary. Seventeen patients (53%) replied that they would rather be at home, nine in hospital (28%) and six had no preference (18.7%). Some previous studies have addressed this question and found different opinions. For some patients, sleeping alone in a laboratory bed can make them feel uncomfortable, anxious, and under observation. In such cases, home recording affords improved comfort and familiarity during studies conducted at appropriate sleep-wake cycle times, with first-night effects minimized. In contrast, other patients may worry more if they are studied without medical supervision 27–.

It is concluded that in patients with suspected sleep apnoea/hypopnoea syndrome, the setting of unattended respiratory monitoring (home or sleep laboratory) influences neither the number of valid studies nor the results of respiratory parameters measured; most patients, however, prefer home studies.

  • Received August 16, 2000.
  • Accepted May 1, 2001.
  • © ERS Journals Ltd

References

  1. ↵
    Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med 1993;328:1230–1235.
    OpenUrlCrossRefPubMedWeb of Science
  2. ↵
    Esnaola S, Duran J, Rubio R, Iztueta A. Prevalence of obstructive sleep apnoea in the male population of Vitoria-Gasteiz (Spain). Eur Respir J 1995;8:Suppl. 19, 436.
    OpenUrlAbstract/FREE Full Text
  3. ↵
    Douglas NJ, Thomas S, Jan MA. Clinical value of polysomnography. Lancet 1999;339:347–350.
    OpenUrl
  4. ↵
    Whittle AT, Finch SP, Mortimore IL, MacKay TW, Douglas NJ. Use of home sleep studies for the diagnosis of the sleep apnoea/hypopnoea syndrome. Thorax 1997;52:1068–1073.
    OpenUrlAbstract
  5. Chesson AL Jr, Ferber RA, Fry JM, et al. The indications for polysomnography and related procedures. Sleep 1997;20:423–487.
    OpenUrlPubMedWeb of Science
  6. Carrasco O, Montserrat JM, Lloberes P, et al. Visual and different automatic scoring profiles of respiratory variables in the diagnosis of sleep apnoea/hypopnoea syndrome. Eur Respir Dis 1996;9:125–130.
    OpenUrl
  7. Lloberes P, Montserrat JM, Ascaso A, et al. Comparison of partially attended night-time respiratory recordings and full PSG in patients with suspected sleep apnoea/hypopnoea syndrome. Thorax 1996;51:1043–1047.
    OpenUrlAbstract/FREE Full Text
  8. ↵
    Godfrey CW, Man BS, Bhavandeep BS. Validation of a portable sleep apnoea monitoring device. Chest 1995;108:388–393.
    OpenUrlCrossRefPubMedWeb of Science
  9. ↵
    Esnaola S, Duran J, Infante-Rivard C, Rubio R, Fernández A. Diagnostic accuracy of a portable device (Mesam IV) in suspected obstructive sleep apnoea. Eur Respir J 1996;9:2597–2605.
    OpenUrlAbstract/FREE Full Text
  10. Emsellem HA, Corson WA, Rappaport BA, Hackett S, Smith LG, Hausfeld JN. Verification of sleep apnoea using a portable sleep apnoea screening device. South Med J 1990;83:748–752.
    OpenUrlPubMedWeb of Science
  11. ↵
    Redline S, Tosteson T, Boucher MA, Millman R. Measurement of sleep-related breathing disturbance in epidemiologic studies. Assessment of the validity and reproducibility of a portable monitoring device. Chest 1991;100:1281–1286.
    OpenUrlCrossRefPubMedWeb of Science
  12. ↵
    Ancoli-Israel S, Kripke DF, Mason W, Messin S. Comparisons of home sleep recordings and polysomnograms in older adults with sleep disorders. Sleep 1981;4:283–291.
    OpenUrlPubMedWeb of Science
  13. Gyulay S, Gould D, Sawyer B, Pond D, Mant A, Saunders N. Evaluation of a microprocessor-based portable home monitoring system to measure breathing during sleep. Sleep 1987;10:130–142.
    OpenUrlPubMedWeb of Science
  14. ↵
    Svanborg E, Larsson H, Carlsson-Nordlander B, Pirskanen R. A limited diagnostic investigation of sleep apnoea syndrome. Oximetry and static charge sensitive bed. Chest 1990;98:341–345.
    OpenUrlCrossRefPubMedWeb of Science
  15. ↵
    Stoohs R, Guilleminault C. Mesam 4: an ambulatory device for the detection of patients at risk for obstructive sleep apnoea syndrome (OSAS). Chest 1992;101:1221–1227.
    OpenUrlCrossRefPubMedWeb of Science
  16. Coppola M, Lawee D. Management of obstructive sleep apnoea syndrome in the home. Chest 1993;104:19–25.
    OpenUrlCrossRefPubMed
  17. ↵
    Kiely JL, Delahunty C, Matthews S, McNicholas WT. Comparison of a limited diagnosis system with polysomnography in the diagnosis of obstructive sleep apnoea. Eur Respir J 1996;9:2360–2364.
    OpenUrlAbstract/FREE Full Text
  18. ↵
    Flemons WW, Remmers JE. The diagnosis of sleep apnoea: questionnaires and home studies? Sleep 1996;19:Suppl. 10, S243–S247.
    OpenUrlPubMedWeb of Science
  19. ↵
    Parra O, Garcia-Esclasans N, Montserrat JM, et al. Should patients with sleep apnoea/hypopnoea syndrome be diagnosed and managed on the basis of home sleep studies? Eur Respir J 1997;10:1720–1724.
    OpenUrlAbstract/FREE Full Text
  20. ↵
    Ballester E, Solans M, Vila X, et al. Evaluation of a portable device for detecting apnoeas and hypopnoeas in subjects from a general population. Eur Respir J 2000;16:123–127.
    OpenUrlAbstract/FREE Full Text
  21. ↵
    Ballester E, Badia JR, Hernandez L, et al. Evidence of the effectiveness of continuous positive airway pressure in the treatment of sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 1999;159:495–501.
    OpenUrlCrossRefPubMedWeb of Science
  22. ↵
    World Medical Association Declaration of Helsinki. Recommendations guiding physicians in biomedical research involving human subjects. JAMA 1997;277:925–926.
    OpenUrlCrossRefPubMedWeb of Science
  23. ↵
    Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307–310.
    OpenUrlCrossRefPubMedWeb of Science
  24. ↵
    Ballester E, Torrego A, Farre R, et al. Sleep lab versus home recording of body posture during sleep. Am J Respir Crit Care Med 1999;159:A795.
    OpenUrl
  25. ↵
    McCall WV, Turpin E, Reboussin DR, Edinger JD, Haponik EF. Subjective estimates of sleep differ from polysomnographic measurements in obstructive sleep apnoea patients. Sleep 1995;18:646–650.
    OpenUrlPubMedWeb of Science
  26. ↵
    Redline S, Sanders MH, Lind BK, et al. Methods for obtaining and analyzing unattended polysomnography data for a multicenter study. Sleep 1998;21:759–767.
    OpenUrlPubMedWeb of Science
  27. Sharpley AL, Solomon RA, Cowen PJ. Sleep stability with home sleep recording and automatic sleep stage analysis. Sleep 1990;13:538–540.
    OpenUrlPubMedWeb of Science
  28. Sharpley AL, Solomon RA, Cowen PJ. Evaluation of first night effect using ambulatory monitoring and automatic sleep stage analysis. Sleep 1988;11:273–276.
    OpenUrlPubMedWeb of Science
  29. Middelkoop HAM, Neven AK, Van Weterin HF. No significant night-to-night variability of home recorded apnoeas in 22 subjects with suspected obstructive sleep apnoea syndrome. J Amb Monit 1993;6:235–241.
    OpenUrl
PreviousNext
Back to top
View this article with LENS
Vol 18 Issue 3 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome
P. Lloberes, G. Sampol, G. Levy, D. Aristizabal, T. Sagales, M. De la Calzada, A. Roca, I. Cañas, F. Morell
European Respiratory Journal Sep 2001, 18 (3) 530-534; DOI: 10.1183/09031936.01.00072401

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome
P. Lloberes, G. Sampol, G. Levy, D. Aristizabal, T. Sagales, M. De la Calzada, A. Roca, I. Cañas, F. Morell
European Respiratory Journal Sep 2001, 18 (3) 530-534; DOI: 10.1183/09031936.01.00072401
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Material and methods
    • Results
    • Discussion
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea
  • Mortality in severe sleep apnoea/hypopnoea syndrome patients: impact of treatment
  • Health utilities in evaluating intervention in the sleep apnoea/hypopnoea syndrome
Show more Original Articles: Sleep

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2023 by the European Respiratory Society