Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart
  • Log out

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions

Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy

F. Sériès, I. Marc
European Respiratory Journal 2001 18: 170-175; DOI:
F. Sériès
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
I. Marc
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional continuous positive airway pressure (CPAP) and auto CPAP therapy was evaluated.

Thirty-three newly treated sleep apnoea hypopnoea syndrome (SAHS) patients were randomly allocated to conventional or auto-CPAP therapy. Six patients of each treatment group were classified as having sleep stage- and body position-dependent obstructive breathing abnormalities according to the results of the baseline sleep study.

After 3 weeks of treatment, the Epworth sleepiness score tended to be higher (p=0.08) and the ability to stay awake lower (p=0.02) in patients with dependent breathing abnormalities treated with fixed CPAP, than in the other patients. The effective pressure/time index was significantly lower in sleep stage- and body position-dependent patients treated with fixed CPAP, than in the other patients (p=0.02). The number of hours the machine was turned on and a positive pressure applied, tended to be smaller in dependent patients treated with fixed CPAP than in independent patients of this treatment group and in patients treated with auto-CPAP. A night-to-night variability index (VI) of positive pressure changes was obtained in the auto-CPAP group. This index significantly decreased with time in the dependent patients while it remained unchanged in the independent group.

It is concluded that auto-continuous positive airway pressure may have specific indications in a subset of obstructive sleep apnoea patients with sleep stage- and body position dependent nocturnal breathing abnormalities.

  • diurnal somnolence
  • effective pressure level
  • positive pressure variability

Nasal continuous positive airway pressure (CPAP) is one of the most effective treatments of the sleep apnoea/hypopnoea syndrome (SAHS). The effective positive pressure level (Peff) is conventionally identified during attended or unattended titration sleep studies and indicates the pressure level required to normalize sleep and respiration in all sleep stages and body positions during the first treatment night. However, this pressure level is influenced by several physiological and clinical situations, including sleep stages, changes in body, neck and jaw position, variations in upper airway vascular tone, hysteresis of the upper airway, duration of CPAP therapy, and weight loss 1–7. Because of the aforementioned factors, positive pressure requirements may dramatically change over time. CPAP therapy should take into account for the intra-night and inter-night variability in positive pressure requirements. This has led to the development of automatic positive pressure devices that have the ability to continuously adapt the positive pressure level during the night.

Only a few studies have been conducted to explore the applicability and accuracy of these newly developed apparatus, most of those performed having been conducted in a sleep laboratory or in hospital 8–10 instead of the home environment 11, 12. Most studies demonstrated a normalization of sleep and respiratory variables during auto-CPAP therapy with a similar improvement in subjective and objective diurnal sleepiness and in neuropsychological performances compared to fixed CPAP 12, 13. With these auto-CPAP machines, a significant percentage of total sleep time can be spent below the effective pressure level 8, 11, with significant changes in the positive pressure level within the different sleep stages and body positions 12, 13. Another important potential advantage of auto-CPAP therapy is that it is associated with an increase in short term treatment compliance 12, 13.

Besides these potential benefits of auto-CPAP therapy, it must be acknowledged that the specific place of auto-CPAP therapy in SAHS treatment strategy is not clearly defined, i.e. should it be prescribed in every patient or only in a subset of patients who would particularly benefit from this new therapeutic alternative? According to the present authors' experience with auto-CPAP and knowing the influence of sleep stages and body positions on the required positive pressure needs, it was hypothesized that patients who have sleep stage- and/or body position-dependent obstructive breathing abnormalities would be more likely to benefit from auto-CPAP therapy.

The aim of the present study was to evaluate the influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional CPAP and auto-CPAP therapy. For this purpose, since the sample sizes of recently published trials on auto-CPAP were too small to conduct the present study 12, 13, the patients who participated to those previous studies were pooled together and a new cohort of patients was enrolled.

Material and methods

Subjects

Forty-eight newly treated SAHS patients, identified by conventional sleep recordings were studied. Forty of them participated in recently published studies on home auto-CPAP 12, 13. They did not receive any medication at the time of the study. None had previous upper airway surgery. The protocol was accepted by the internal review board of Laval University, Quebec, Canada, and each patient signed an informed consent form for acceptance to participate to the study.

Sleep studies

Sleep recording consisted of the continuous acquisition of: electroencephalogram (C4A1, C3A2, O2A1); electroculogram (EOG); submental and anterior tibialis electromyogram (EMG); electrocardiogram (ECG); combined oro-nasal flow with thermistors placed in front of the nares and the mouth (ONT 2, Grass instruments, Astromed, Longueuil, PQ, Canada); thoracoabdominal movements with inductive plethysmography (Respitrace®, Ambulatory monitoring, Arsdley, NY, USA) calibrated with the isovolume method 14; arterial oxyhaemoglobin saturation with an ear oximeter (504 pulse oximeter, Criticare systems, Waukesha, WI, USA); and breathing noises with two microphones placed at the head of the bed 15. Body position was checked during the sleep recordings by the attending technician, according to continuous infrared monitoring. During CPAP nights, flow was measured via a pneumotachograph connected to the nasal CPAP mask.

Protocol

Diurnal sleepiness was subjectively assessed by the Epworth sleepiness score (ESS) 16, and the ability to stay awake with the Maintenance of wakefulness test (MWT) 17, before initiating CPAP therapy. Every patient had a conventional titration sleep study to determine the Peff level. They were then randomly allocated to fixed (n=24) or auto-CPAP (n=24) therapy using the same auto-CPAP machine (Morphée Plus/Cloudnine, Nelcorr Puritan Benett, Minneapolis, MN, USA) for 3 weeks. For the 40 patients who participated in the aforementioned previous auto-CPAP studies, the constant and auto-CPAP groups were paired for the apnoea/hypopnoea index (AHI) and body mass index (BMI) (n=8) or for Peff (n=12). The eight additional subjects were paired for Peff.

In the conventional CPAP group, the machine was set at Peff and used in the constant mode. In the auto-CPAP group, the Morphée Plus setting requires the determination of a reference pressure on each side of which the pressure is allowed to change inside upper and lower limits that are separately chosen by the physician. Reference pressure was set at the Peff value, with upper and lower pressure limits set at +2/−4 cmH2O in eight subjects, and +3/−4 cmH2O in the 12 others. A control sleep study was obtained at the end of the CPAP trial using the machine and the pressure setting prescribed for the three previous weeks. ESS score and MWT test were obtained during the day following the control sleep study.

Data and statistical analysis

Sleep and respiratory variables were manually interpreted according to standard criteria 18, 19. Treatment compliance was evaluated by the time the machine was turned on (machine running time), the time a positive pressure was applied (positive pressure-time), and their ratio (effective pressure time index). Patients were classified as having sleep stage- or body position-dependent nocturnal breathing abnormalities when there was a minimum of 100% difference in the apnoea/hypopnoea index between the different sleep positions (lateral, supine) in nonrapid eye movement (REM) sleep or between stages I and II, and REM in the same sleep position. Patients were defined as having sleep stage- and body position-dependent nocturnal breathing abnormalities when both sleep stage-dependence criteria were met.

In patients of the auto-CPAP group, the amount of pressure delivered at the different pressure levels was assessed by a print out of the percentage of the positive pressure-time spent at the different pressure levels for each treatment night during the 3 weeks of home CPAP therapy. The degree of pressure changes was quantified by the VI, which took into account the percentage of positive pressure time spent at the different pressure levels. The same formula that is used to determine the variance of a frequency variable was used: VI=Σi (i−A)2·Pi, where i represents the positive pressure value from 4–20 cmH2O in 2 cmH2O increments, Pi is the percentage of positive pressure time spent at the different positive pressure levels, and A=Σi I·Pi. According to this index calculation, VI is 0 if the whole night was spent at the same pressure level and 5 if the time spent at the different pressure levels is identical. The maximal possible value of VI is 9 and corresponds to the situation where 50% of the treatment time is spent at the two extreme pressure values respectively.

The different analysed parameters were compared using a two-way ANOVA to evaluate the interaction effects of treatment mode and sleep stage/body position-dependence status. Parameters measured at baseline and after treatment were compared with a repeated measure design. Normality of variance assumptions were verified to validate statistical tests. The distribution of total sleep time between different sleep stages was transformed with an arcsin function and expressed as a percentage. Statistical significance was inferred for p-values<0.05.

Results

Six patients from the conventional CPAP group and six patients from the auto-CPAP group were classified as having sleep stage- and body position-dependent obstructive breathing abnormalities. The sleep stage- and body position-dependence could not be characterized in 15 patients who did not change body position or whose sleep architecture did not include REM sleep during baseline sleep recording. These subjects were therefore excluded from the comparison between sleep stages/body position-dependent and independent patients. Analysis was done with 33 subjects, 16 undergoing conventional CPAP and 17 auto-CPAP therapy. There was no difference in the subject characteristics between the 48 patients recruited for the study, the 40 who participated in the previously published papers and the 33 in whom the body position- and sleep stage-dependency was definable. In the subjects of the auto-CPAP group who had sleep stage- and body position-dependent breathing disorders, the upper and lower pressure limits were set at +2/−4 cmH2O in three patients and at +3/−4 cmH2O in the other three.

Patients of the two treatment groups (constant and auto-CPAP) had identical age, body mass index, apnoea/hypopnoea and sleep fragmentation indices, and Peff values (tables 1 and 2⇓⇓). Subjective and objective baseline assessment of diurnal sleepiness and Peff level were similar in these two groups (table 2⇓). No difference was found in these variables between patients with or without sleep stage/body position-dependent breathing abnormalities in each treatment group.

View this table:
  • View inline
  • View popup
Table 1—

Anthropometric and nocturnal breathing characteristics of the patients in each treatment group.

View this table:
  • View inline
  • View popup
Table 2—

Characteristics of patients with and without sleep stage- and body position-dependence of nocturnal breathing disorders in each treatment group.

Body weight and neck circumference did not change during the treatment course. Sleep architecture and breathing characteristics and diurnal somnolence improved in each treatment group whatever the sleep stage- body position-dependent or independent status (table 2⇑). At the end of the treatment period, patients treated with fixed CPAP who had dependent breathing abnormalities demonstrated more daytime sleepiness compared to the other patients of this treatment group and to those of the auto-CPAP group, as suggested by the higher Epworth sleepiness score (p=0.08) and lower ability to stay awake (p=0.02) (table 2⇑). Similarly, diurnal sleepiness improved in dependent and independent patients of the auto-CPAP treatment group. In the auto-CPAP group, the percentage of positive pressure-time that was spent below Peff during home CPAP trial was significantly greater in the dependent group than in the independent group (p=0.009).

The machine running time was similar in the fixed and auto-CPAP treatment groups. However, the positive pressure-time and the effective pressure time index were significantly less in the fixed CPAP group than in the auto-CPAP group (p=0.006). The machine running time, positive pressure-time (fig. 1a⇓), and effective pressure-time index (fig. 1b⇓) were smaller in patients of the fixed CPAP with dependent breathing disorders with than in the other groups. This difference did not reach significance for the first two variables but was significant for the third one (p=0.02).

Fig. 1.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 1.—

Mean±sd values of a) the machine running time (□) and positive pressure time (└), and b) and effective pressure time index in each treatment group, depending on their sleep stage/body position-dependency. The effective pressure time index is defined as the ratio of the number of hours a pressure is delivered to the number of hours the machine is turned on. The parameters measuring treatment duration tended to be lower in dependent patients treated with fixed continuous positive airway pressure (CPAP) but these differences did not reach significance. The effective pressure index was significantly lower in this group compared to others. *: significant difference (p<0.05) between indicated groups.

The above mentioned differences in treatment efficiency between patients with dependent breathing disorders treated with fixed CPAP and patients of the other groups were not observed if sleep stage- or body position-dependency were considered alone.

No difference was found in VI between sleep stage/body position dependent and independent patients for the overall treatment period (5.9±2.2 and 5.3±2.6, respectively, p=0.12). This index was found to significantly decrease with time in the dependent patients while it remained unchanged in the independent group (fig. 2⇓).

Fig. 2.—
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig. 2.—

Mean±sd values of the variability index measured day-by-day in patients of the auto-CPAP group, with (□) and without (•) sleep stage- and body position-dependence of nocturnal breathing abnormalities. This index tended to decrease with time. No significant difference was found in the changes in VI with time between the two groups.

Discussion

To the authors' knowledge, this is the first study to look at the influence of body position- and sleep stage-dependence of obstructive breathing abnormalities and CPAP mode on CPAP efficiency.

The criteria that were used to define body position-dependence is the same as that previously used by Shepard and coworkers 20, 21. Interestingly, these authors found that, in a retrospective study of 100 patients, 43% of patients with body position-dependent nocturnal breathing disorders also had a sleep stage-dependence according to the criteria that were used in the present study; therefore, the prevalence of sleep stage- and body position-dependence in their study population was 21%, which is very close to that observed in the present study in those patients where this dependency could be analysed (25%).

The present results suggest that CPAP compliance and the benefits of treatment on neuropsychological variables are improved with auto-CPAP therapy in patients with sleep stage- and/or body position-dependent nocturnal breathing disorders, compared to fixed CPAP. This is of primary importance when objective compliance to CPAP therapy is poor; only 46% of patients treated with fixed CPAP apparatus use it at least 4 h·day−1 22. According to the prevalence of body position- and sleep stage-dependence that were observed in the present study, auto-CPAP therapy may be more effective than conventional CPAP treatment in 25% of obstructive sleep apnoea (OSA) patients. On the other hand, the present results suggest that in patients with no such body position- and sleep stage-dependence, auto-CPAP therapy may not bring additional benefits compared to fixed CPAP. Therefore, auto-CPAP therapy may have specific indications in a subset of OSA patients, but is obviously not more effective than conventional CPAP in the majority of sleep apnoea patients. These parameters should be taken into account in any clinical trial comparing auto-CPAP and conventional CPAP efficiencies.

Body position and sleep stage have been shown to significantly influence the positive pressure level that abolishes obstructive breathing abnormalities 1, 2. The present authors are aware that several other factors also contribute to determine the positive pressure needs, and potentially, the changes in positive pressure requirements within the night, and from one night to another 3–5. This can account for the important scatter in VI that was found in both groups (fig. 2⇑). However, it is particularly interesting to note that the behaviour of this index with time, differed between the groups with different sleep stage- and/or body position-dependence status, with the VI decreasing with time in patients with dependent breathing abnormalities. Several factors can contribute to the decrease in VI over time such as the greater stability in body position during CPAP therapy 23 and the improvement in upper airway shape and/or dimension 24. Several other factors may obviously be involved that remain to be investigated.

The observation that VI progressively decreases in dependent patients, to become similar to that of the independent group within 3 weeks of treatment, suggests that the benefits of auto-CPAP machines may be limited during the first weeks of treatment. Further studies should be conducted to analyse if VI values, and its changes during the course of CPAP therapy, may bring additional information on auto-CPAP behaviour, independently of the sleep stages- and or body position-dependent and independent status.

It is concluded that patients with body position- and/or sleep stage-dependency of nocturnal breathing disturbances, may benefit more from auto-continuous positive airway pressure therapy than from fixed continuous positive airway pressure, at least during the initial course of their treatment. Long-term prospective, randomized trials are needed to determine if additional factors can help to identify patients whose compliance and clinical response would be enhanced by using auto-continuous positive airway pressure devices and to investigate if positive pressure variations may be helpful in identifying them.

  • Received October 20, 1998.
  • Accepted May 25, 2001.
  • © ERS Journals Ltd

References

  1. ↵
    Issa FG, Sullivan CE. Upper airway closing pressures in obstructive sleep apnea. J Appl Physiol 1984;57:520–527.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Thut DC, Schwartz AR, Roach D, Wise RA, Permutt S, Smith PL. Tracheal and neck position influence upper airway airflow dynamics by altering airway length. J Appl Physiol 1993;75:2084–2090.
    OpenUrlAbstract/FREE Full Text
  3. ↵
    Wasicko MJ, Hutt DA, Parisi RA, Neubaeur JA, Mezrich R, Edelman NH. The role of vascular tone in the control of upper airway collapsibility. Am Rev Respir Dis 1990;141:1569–1577.
    OpenUrlPubMedWeb of Science
  4. Meurice JC, Marc I, Carrier G, Sériès F. Effects of mouth opening on upper airway collapsibility in normal sleeping subjects. Am J Respir Crit Care Med 1996;153:255–259.
    OpenUrlPubMedWeb of Science
  5. ↵
    Condos R, Norman RG, Krisnasamy I, Peduzzi N, Goldring RM, Rapoport DM. Flow-limitation as a noninvasive assessment of residual upper-airway resistance during continuous positive airway pressure therapy of obstructive sleep apnea. Am J Respir Crit Care Med 1994;150:475–480.
    OpenUrlPubMedWeb of Science
  6. Sériès F, Marc I, Cormier Y, La Forge J. Required levels of nasal continuous positive airway pressure during treatment of obstructive sleep apnoea. Eur Respir J 1994;7:1776–1781.
    OpenUrlAbstract
  7. ↵
    Schwartz AR, Gold AR, Schubert N, et al. Effect of weight loss on upper airway collapsibility in obstructive sleep apnea. Am Rev Respir Dis 1991;144:494–498.
    OpenUrlCrossRefPubMedWeb of Science
  8. ↵
    Scharf MB, Brannen DE, McDannold MD, Berkowitz DV. Computorized adjustable versus fixed NCPAP treatment of obstructive sleep apnea. Sleep 1996;19:491–496.
    OpenUrlPubMedWeb of Science
  9. Sharma S, Wali S, Pouliot Z, Peters M, Neufeld H, Kryger M. Treatment of obstructive sleep apnea with self-titrating continuous positive airway pressure system. Sleep 1996;19:497–501.
    OpenUrlPubMedWeb of Science
  10. ↵
    Lofaso F, Lorino AM, Duizabo D, et al. Evaluation of an auto-CPAP device based on snoring detection. Eur Respir J 1996;9:1795–1800.
    OpenUrlAbstract/FREE Full Text
  11. ↵
    Berthon-Jones M, Lawrence S, Sullivan CE, Grunstein R. Nasal continuous positive airway pressure treatment: current realities and future. Sleep 1996;S131–S135.
  12. ↵
    Meurice JC, Marc I, Sériès F. Efficiency of auto-cpap in the treatment of obstructive sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 1996;153:794–798.
    OpenUrlPubMedWeb of Science
  13. ↵
    Sériès F, Marc I. Efficacy of automatic continuous positive airway pressure that uses an estimated required pressure level in the treatment of obstructive sleep apnea syndrome. Ann Intern Med 1997;8:588–595.
    OpenUrl
  14. ↵
    Chadha TS, Watson H, Birch S, et al. Validation of respiratory inductive plethysmography using different calibration procedures. Am Rev Respir Dis 1982;125:644–649.
    OpenUrlPubMedWeb of Science
  15. ↵
    Sériès F, Sériès I, Atton L. Comparison of snoring characteristics obtained by polysomnographic studies and home recordings. Chest 1993;103:1769–1773.
    OpenUrlCrossRefPubMedWeb of Science
  16. ↵
    Johns MW. Daytime sleepiness, snoring, and obstructive sleep apnea. The Epworth sleepiness scale. Chest 1993;103:30–36.
    OpenUrlCrossRefPubMedWeb of Science
  17. ↵
    Poceta JS, Timms RM, Jeong DU, Ho JL, Erman MK, Mitler MM. Maintenance of wakefulness test in obstructive sleep apnea syndrome. Chest 1992;101:893–897.
    OpenUrlCrossRefPubMedWeb of Science
  18. ↵
    Rechtschaffen A, Kales A. . A manual of standardized terminology, techniques and snoring system for sleep stages of human subjects. Public Health Service, Washington D.C., National Institutes of Health publication 204, 1968.
  19. ↵
    American Sleep Disorders Association. EEG arousals: scoring rules and examples. Sleep 1992;15:174–183.
    OpenUrlWeb of Science
  20. ↵
    Pevernagie DA, Shepard JW. Relations between sleep stage, posture and effective nasal CPAP levels in OSA. Sleep 1992;15:162–167.
    OpenUrlPubMedWeb of Science
  21. ↵
    Pevernagie DA, Stanson AW, Sheedy PF, Daniels BK, Shepard JW. Effects of body position on the upper airway of patients with obstructive sleep apnea. Am J Respir Crit Care Med 1995;152:179–185.
    OpenUrlPubMedWeb of Science
  22. ↵
    Kribbs NB, Packs AI, Kline LR, et al. Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis 1993;147:887–895.
    OpenUrlCrossRefPubMedWeb of Science
  23. ↵
    Sériès F, Marc I, Cormier Y, La Forge J. Required levels of nasal continuous positive airway pressure during treatment of obstructive sleep apnoea. Eur Respir J 1994;7:1776–1781.
  24. ↵
    Ryan CF, Lowe AA, Li D, Fleetham JA. Magnetic resonance imaging of the upper airway in obstructive sleep apnea before and after chronic nasal continuous positive airway pressure therapy. Am Rev Respir Dis 1991;144:939–944.
    OpenUrlCrossRefPubMedWeb of Science
PreviousNext
Back to top
View this article with LENS
Vol 18 Issue 1 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
Citation Tools
Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy
F. Sériès, I. Marc
European Respiratory Journal Jul 2001, 18 (1) 170-175;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy
F. Sériès, I. Marc
European Respiratory Journal Jul 2001, 18 (1) 170-175;
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo CiteULike logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
    • Abstract
    • Material and methods
    • Results
    • Discussion
    • References
  • Figures & Data
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea
  • Mortality in severe sleep apnoea/hypopnoea syndrome patients: impact of treatment
  • Health utilities in evaluating intervention in the sleep apnoea/hypopnoea syndrome
Show more Original Articles: Sleep

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2022 by the European Respiratory Society