Abstract
The class label warning in the United States for inhaled corticosteroids (ICS's) states that these drugs may reduce growth velocity in children. In this paper, the evidence for this warning is reviewed from a clinical point of view.
Children with asthma tend to grow slower than their healthy peers during the prepubertal years because they go into puberty at a later age. However, asthmatic children do achieve a (near) normal adult height. In randomized controlled clinical trials, the use of inhaled beclomethasone, budesonide and fluticasone is associated with a reduced growth during the first months of therapy, in the order of magnitude of approximately 0.5–1.5 cm·yr−1. It is, however, unlikely that such an effect continues or persists because accumulating evidence shows that asthmatic children, even when they have been treated with ICS for years, attain normal adult height. Individual rare cases have been reported, however, where ICS use was associated with clinically relevant growth suppression.
Inhaled corticosteroids are the most effective therapy available for maintenance treatment of childhood asthma. Fear of reduced growth velocity is based on exceptional cases and not on group data. It should, therefore, not be a reason to withhold or withdraw such highly effective treatment in children with asthma.
In the summer of 1998, the Pulmonary-Endocrine Drugs Advisory Committee of the American Food and Drug Administration (FDA) convened in Bethesda, USA to review data on the effect of inhaled corticosteroids (ICS's) on growth of children with asthma. The Committee decided by conrevsus to alter the class labelling for all intranasal and inhaled corticosteroids in children to include a precautionary statement that the use of these drugs in recommended doses may be associated with a reduction in growth velocity. This committee decision received widespread attention throughout the world by paediatricians being concerned about the possible side effects of ICS therapy.
At about the same time, a 13 yr old girl with moderately severe asthma, was referred to the present author by a general paediatrician because her growth was reduced during ICS treatment (fig. 1⇓). Four and a half years previously, at the age of 8, she was started on inhaled beclomethasone dipropionate (BDP) 400 µg daily, by dry powder inhaler (DPI), because her asthmatic symptoms were insufficiently controlled on inhaled bronchodilators alone. After she started ICS's, her asthma was well controlled; attempts to reduce the daily dose resulted in recurrence of troublesome nocturnal symptoms. Her mother was very concerned about her daughter’s growth (“She's now by far the smallest girl in her class, doctor!”) and brought with her a summary of the FDA Committee's report downloaded from the Internet. She requested support for her decision to stop ICS treatment and to start her on another form of anti-inflammatory maintenance therapy.
What are the issues in this case?
Every paediatrician is familiar with cases such as this. Before making a decision on withdrawing or continuing ICS treatment in a case such as this, the evidence on several issues needs to be reviewed (table 1⇓). Then, the applicability of the evidence to the particular case should be addressed; what are the pros and cons of ICS treatment in this child, and how should they be balanced?
What are the effects of corticosteroids on growth in general?
There is convincing evidence that daily maintenance treatment with systemic corticosteroids reduces growth in children with various diseases 1, 2. Alternate-day oral corticosteroid therapy is also associated with reduced growth, but to a lesser degree than a daily schedule 3. The cumulative growth-reducing effect of systemic corticosteroids may amount to more than 10 cm, although many children continue to grow normally even during long-term systemic steroid therapy 4. Because the risk of growth suppression during treatment with systemic corticosteroids is large, the concern that inhaled corticosteroids might also be growth-suppressive, is understandable 5.
What is the bioavailability of inhaled corticosteroids?
Inhaled corticosteroids can only reduce growth after they become available systemically. Systemic side effects of ICS's are determined by absorption from the lung and the gut (fig. 2⇓) 6–8. The amounts of drug that are deposited in the lung and in the oropharynx depend largely on the type of inhaler device being used and on the patient's inhalation technique 9, 10. If a spacer device is being used, oropharyngeal deposition is low; the largest proportion of the drug that is not deposited into the lung remains in the spacer 11, 12. If a DPI or a metered dose inhaler (MDI) without a spacer is used, a considerable proportion of the inhaled drug (up to 60%) is deposited in the oropharynx, swallowed and may thus contribute to systemic availability 13, 14. Under these circumstances, systemic bioavailability depends on the degree of first-pass inactivation in the liver, which is larger for fluticasone propionate (FP, 99%) and budesonide (BUD 90%) than for BDP (70%) 15. Oropharyngeal deposition can be reduced by mouth rinsing 16. Regardless of the inhalation device and the specific drug inhaled, systemic bioavailability is predominantly determined by the amount of drug deposited into the lung (fig. 2⇓) 9. Improved lung deposition will, therefore, inevitably lead to increased systemic availability of ICS's. It can be assumed that lung deposition is higher in healthy subjects and in patients with mild asthma, than in patients with more severe airways obstruction 17.
The potential of systemically available ICS's to cause side effects is also determined by their pharmacokinetic properties. FP, being the most lipophilic ICS, not only has the largest corticosteroid receptor affinity, but also has a larger volume of distribution and a longer elimination half-life than other ICS's 18. This may help to explain why FP causes more adrenal suppression than BUD, in particular during steady state daily dosing 19–22. During single-dose studies, accumulation of lipophilic compounds does not occur and systemic effects may be less clear 23. Studies on systemic side effects of ICS's, are therefore best performed during steady state dosing.
What is the dose-effect relationship of inhaled corticosteroids for systemic side effects?
Both anti-inflammatory and systemic effects of corticosteroids are dose-dependent, but the dose-response curves of pulmonary and systemic effects differ markedly (fig. 3⇓) 7, 24, 25. The dose-response curve for pulmonary effects appears to have its steep part at relatively low daily doses, to flatten off towards higher daily doses. For systemic effects, the reverse pattern applies (fig. 3⇓). Although this basic principle applies for all ICS's available today, the exact dose-response curves may differ between various compounds, and even between different individuals using the same compound 15. It is likely that genetically determined polymorphism in the glucocorticoid receptor explains the intra-individual differences in sensitivity to corticosteroid effects 26.
The basic principle is best explained by a clinical example. Increasing the daily dose of an ICS from, say, 100 to 200 µg will markedly improve its efficacy with little or no increased risk of systemic effects, whereas an increase from, say, 800 to 1600 µg will yield little extra efficacy at the expense of a markedly increased risk of systemic side effects.
How do children with asthma grow when they are not treated with inhaled corticosteroids?
As is the case with any chronic disease, asthma itself may reduce growth. Although this attenuation of growth is highly variable between individual patients, it appears to be related to the severity of the disease, being most pronounced in chronic, poorly controlled asthma. Nevertheless, a reduction in prepubertal growth and a delay in the onset of puberty and the pubertal growth spurt may also be found in well-managed and well-controlled asthma 27–30. The underlying cause of this phenomenon is poorly understood. Studies have shown that although puberty and the pubertal growth spurt occur later than usual, they are not abnormal in any other way, and asthmatic children show catch-up growth later on to reach normal or near-normal adult height 31, 32.
What are the effects of inhaled corticosteroids on growth in asthmatic children? Retrospective studies
The difference in growth between children with mild and severe asthma complicates the interpretation of any retrospective data on growth in asthmatic children being treated with ICS's. In 1981, Littlewood et al. 33 were the first to report slower growth in asthmatic children being treated with ICS's. They retrospectively compared height standard deviation scores (SDS) of 249 children with asthma being treated with inhaled bronchodilators or cromolyn sodium, to those of 81 children using BDP, and found that the height SDS scores of children on ICS's were on average 0.5 lower than those on bronchodilators or cromolyn. However, because in the late 1970s and early 1980s ICS's were only given to children with severe asthma, it is quite possible that the slower growth in the ICS group was due to the more severe asthma itself rather than its treatment with ICS. A number of other similarly designed retrospective studies on ICS's and growth in asthmatic children were published subsequently. These studies were summarized in a meta-analysis in 1994 1: in the pooled analysis, the effect of ICS's on growth was not statistically significant. It follows from the above that prospective studies are needed to reveal the true effect of ICS's on growth.
What are the effects of inhaled corticosteroids on growth in asthmatic children? Prospective controlled clinical trials
Short-term studies (weeks)
A number of well-designed controlled clinical trials have examined the short-term effects of ICS's on growth using knemometry. Since, by using this method, lower leg length can be measured with an accuracy of 0.1 mm, it is uniquely fitted to monitor growth over a period of days to weeks 34. Although such short-term growth rates do not predict longer term growth in any meaningful way 35, the knemometer is considered to be the most valuable tool in determining short-term ICS systemic side effects 36. The results of five of these knemometric cross-over studies comparing short-term growth during treatment with and without ICS's are summarized in fig. 4 37–41. There is a dose-dependent reduction of lower leg growth during short-term treatment with ICS which is most pronounced for BDP. A recent study showed that lower leg growth was less suppressed during a 4 week treatment period with BUD (800 µg·day) when it was given in a single daily dose compared to when it was divided into two doses of 400 µg each 42, supporting the hypothesis that the effects of ICS's on growth may be less pronounced during once daily dosing than with twice daily dosing 5.
Medium-term studies (months)
Ten controlled clinical trials studying the effects of ICS's on growth during several months have been published to date (table 2⇓). Four studies compared BDP 400 μg·day−1 to other treatments (theophylline, salmeterol, or placebo). Despite the differences in study design, drug used in the control group, inhaler device used and age range, the results of these studies were remarkably consistent: children using BDP grew significantly slower (up to 1.8 cm·yr−1) than children from the control group 43–46. Such a growth retarding effect was not found in two studies comparing BUD by MDI and spacer to other maintenance therapies over months to years of follow-up 47, 48. However a small, but statistically significant, reduction in growth velocity was found during one year maintenance therapy with BUD inhalation suspension, (table 2⇓) 49. Similarly, a recent study showed that the growth of children during the first year of treatment with BUD by DPI was 1.1 cm less than that of children using placebo or nedocromil 50. Interestingly, this small reduction in growth velocity during the first year of therapy did not persist during further follow-up 4–6 years 50. It appears, therefore, that the effects of ICS's on growth velocity are temporary.
One open-label study compared growth rates between 1 yr maintenance therapy with FP (100 µg·day−1) and that with cromolyn. Although the patients from the FP group grew on average 0.5 cm·yr−1 slower than children from the cromolyn group, the difference was not statistically significant 51. Another study comparing growth in asthmatic children treated for 1 yr with placebo and FP (100 and 200 µg daily) reported no significant overall difference in growth rates between groups 52. However, when the difference in growth rates between each of the two FP groups separately compared to placebo were analysed, the group using the higher dose (200 µg daily) showed significantly reduced growth of 0.42 cm·yr−1 (table 2⇑). Similar results were reported in a meta-analysis on the effects of fluticasone on growth 53.
Long-term studies (final height)
Even if ICS treatment does reduce growth in the short-term or the medium-term, it is entirely conceivable that this effect is only temporary, like the effect of the disease asthma itself, and that final adult height is unaffected. From the few studies published on adult height in asthmatic patients being treated with ICS's, this appears to be the case 4, 30–32, 54–56. The results of these studies are summarized in table 3⇓. It should be stressed that the numbers of patients in these studies were small and that most studies were retrospective 4, 55, 56. Moreover, the use of a control group of asthmatics not using ICS's may not be valid because it is likely that the children in the ICS treatment group had more severe asthma than the children in the control group, which may have affected their growth and final height. Given the reassuring results from most of the studies presented in table 3⇓, it is acceptable to conclude that at present there is no evidence that ICS's reduce final attained height. It is important to emphasize that this appears to be true not only inhospital-based populations of moderate-to-severe asthmatics 4, 30, 54–56, but also in a general population-based study of mild asthmatics 31, 32. Thus, even in mild asthmatics, in whom the risk of systemic side effects is considered to be greatest 15, 17, there does not appear to be a detrimental effect of long-term ICS therapy on final adult height.
Applicability of the evidence to the individual case
The evidence presented above suggests that although ICS (particularly BDP) treatment may suppress short- and medium-term growth in children with asthma, the effect is probably temporary. Indeed, in two studies, growth was reduced during the first year of ICS therapy as compared to children not treated with ICS's, but the growth during this first year of therapy was not associated with final height, and no effect of ICS's on final height was found 50, 54. Thus, even if ICS's are used for many years, it is unlikely that they cause permanent growth retardation or reduced adult height in asthmatic children.
A second justified conclusion is that the effects of ICS therapy on growth over a period of weeks to months are dose-dependent. Higher doses should be used with caution in any patient, as they only improve efficacy slightly, but increase the risk of side effects (including reduced growth) quite substantially (fig. 3⇑). In patients not doing well on high doses of ICS's, it is important to consider poor compliance, faulty inhalation technique 57 or alternative diagnoses 58 before increasing the dose any further.
It is important to emphasize that the overall evidence arguing against a clinically relevant and persistent growth retarding effect of ICS's in childhood asthma, does not exclude a clinically relevant growth retarding effect of ICS's in an individual case such as this. Case reports have been published showing serious growth suppression during maintenance therapy with BDP 59, 60 BUD 61 and FP 62. Although the risk of such growth suppression is higher when high doses of ICS's are used, clinically significant growth suppression may occur at any dose of ICS in any patient. This suggests that reduced growth during ICS therapy is an idiosyncratic event – the result of increased individual sensitivity of the particular patient to the systemic side effects of corticosteroids. If the mechanisms underlying this phenomenon (probably involving a glucocorticoid receptor polymorphism 26) are unravelled, such patients may, in the future, be identified before they experience serious side effects of steroid therapy.
There is accumulating evidence that growth suppression occurs primarily during the first 3–12 months of ICS therapy 50, 54, 63. Thus, if a patient grows well during the first 6 months of ICS therapy, the risk of this patient developing growth suppression subsequently is small. It is important, however, to continue to monitor growth in all asthmatic children using ICS's. Only then can the individual cases of delayed onset of puberty or significant growth retardation be identified.
So what about the patient?
Considering all the above, how should we interpret the patient's growth curve? The reduction of growth velocity appears to commence at the age of 8, at about the time ICS therapy was started. Over the 5 years that followed, her height standard deviation score (SDS) went from around zero (the population mean) to −1.45 at the age of 13. A reduction in height growth of more than 0.25 SDS·yr−1 is considered by paediatric endocrinologists to be clinically significant, and to warrant further investigation 64.
At physical examination, the girl was apparently in good health. There were no signs of puberty (Tanner stages P1 M1) and her breath sounds were clear; there was no wheezing. Further physical examination was unremarkable. Her bone age was 11.5 yrs according to the Tanner & Whitehouse method.
The conclusion was that the patient's growth was retarded due to a delayed onset of puberty, as may be seen in up to 50% of asthmatic children 30. Other than the concurrence in time, there was no particular reason to assume that her slow growth was in any way related to the ICS therapy. It was decided to continue the patient's ICS therapy, and she was switched from BDP to FP by DPI (200 µg daily). She turned down the offer to have her puberty induced medically. Further follow-up proved her right, as puberty developed spontaneously shortly afterwards and she showed a normal (though delayed) pubertal growth spurt. At follow-up recently, at the age of 16, her height was 170 cm – well within her target height range (fig. 5⇓).
Conclusion
Although there is consistent evidence that inhaled corticosteroids reduce short-term growth and reduce growth velocity by approximately 1 cm·yr−1 during the first year of treatment, at present there is no reason to assume that maintenance therapy with inhaled corticosteroids in “normal” daily doses (up to 400 µg·day−1 for beclomethasone diproprionate or budesonide, or 200 µg·day−1 for fluticasone proprionate) causes clinically relevant growth suppression or reduced final height in the overall majority of patients. Because idiosyncratic responses (increased sensitivity to the systemic effects of inhaled corticosteroids) cannot be ruled out in the individual patient, careful monitoring of growth during inhaled corticosteroid therapy in children with asthma is recommended. If height growth is reduced by more than 0.25 standard deviation score·yr−1, further investigation is warranted. The most common cause for prepubertal growth suppression in asthmatic children using inhaled corticosteroids is delayed onset of puberty (as was the case in the patient). This can be easily diagnosed by physical examination and determination of bone age. Even in the rare event of a truly clinically relevant growth suppression due to inhaled corticosteroid therapy, the reasons to continue therapy (well controlled asthma) almost always outweigh the reasons to withdraw treatment (slower growth). Fear of reduced growth velocity should not be a reason to withhold or withdraw this highly effective treatment in asthmatic children, and the American Food and Drug Administration class label warning should be adjusted accordingly.
- Received May 20, 2000.
- Accepted October 18, 2000.
- © ERS Journals Ltd