Skip to main content

Main menu

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

User menu

  • Log in
  • Subscribe
  • Contact Us
  • My Cart

Search

  • Advanced search
  • ERS Publications
    • European Respiratory Journal
    • ERJ Open Research
    • European Respiratory Review
    • Breathe
    • ERS Books
    • ERS publications home

Login

European Respiratory Society

Advanced Search

  • Home
  • Current issue
  • ERJ Early View
  • Past issues
  • Authors/reviewers
    • Instructions for authors
    • Submit a manuscript
    • Open access
    • COVID-19 submission information
    • Peer reviewer login
  • Alerts
  • Podcasts
  • Subscriptions

Diaphragm electromyogram measured with unilateral magnetic stimulation

YM Luo, LC Johnson, MI Polkey, ML Harris, RA Lyall, M Green, J Moxham
European Respiratory Journal 1999 13: 385-390; DOI:
YM Luo
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
LC Johnson
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
MI Polkey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
ML Harris
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
RA Lyall
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M Green
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J Moxham
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

The purpose of this study was to establish the phrenic nerve conduction time (PNCT) for magnetic stimulation and further assess the relatively new technique of anterior unilateral magnetic stimulation (UMS) of the phrenic nerves in evaluating the diaphragm electromyogram (EMG). An oesophageal electrode was used to record the diaphragm compound muscle action potential (CMAP) elicited by supramaximal percutaneous electrical phrenic nerve stimulation (ES) and UMS from eight normal subjects. The oesophageal electrode used for recording the CMAP was positioned at the level of the hiatus and 3 cm below. The diaphragm CMAP was also recorded from chest wall surface electrodes in five subjects. All of the phrenic nerves could be maximally stimulated with UMS. A clear plateau of the amplitude of the CMAP was achieved for the right and left phrenic nerves. The mean amplitudes of the CMAP recorded from the oesophageal electrode were, for the right side, 0.74+/-0.29 mV (mean+SD) for ES and 0.76+/-0.30 mV for UMS with maximal power output, and for the left side 0.88+/-0.33 mV for ES and 0.80+/-0.24 mV for UMS. PNCT measured by the oesophageal electrode with ES and UMS with maximal output were, for the right side, 7.0+/-0.8 ms and 6.9+/-0.8 ms, respectively, and for the left side 7.8+/-1.2 ms and 7.7+/-1.3 ms, respectively. However, the CMAP recorded from chest wall surface electrodes with UMS was unsuitable for the measurement of PNCT. The results suggest that unilateral magnetic stimulation of the phrenic nerves combined with an oesophageal electrode can be used to assess diaphragmatic electrical activity and measure the phrenic nerve conduction time.

PreviousNext
Back to top
Vol 13 Issue 2 Table of Contents
  • Table of Contents
  • Index by author
Email

Thank you for your interest in spreading the word on European Respiratory Society .

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Diaphragm electromyogram measured with unilateral magnetic stimulation
(Your Name) has sent you a message from European Respiratory Society
(Your Name) thought you would like to see the European Respiratory Society web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Alerts
Sign In to Email Alerts with your Email Address
Citation Tools
Diaphragm electromyogram measured with unilateral magnetic stimulation
YM Luo, LC Johnson, MI Polkey, ML Harris, RA Lyall, M Green, J Moxham
European Respiratory Journal Feb 1999, 13 (2) 385-390;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

Share
Diaphragm electromyogram measured with unilateral magnetic stimulation
YM Luo, LC Johnson, MI Polkey, ML Harris, RA Lyall, M Green, J Moxham
European Respiratory Journal Feb 1999, 13 (2) 385-390;
del.icio.us logo Digg logo Reddit logo Technorati logo Twitter logo Connotea logo Facebook logo Google logo Mendeley logo
Full Text (PDF)

Jump To

  • Article
  • Info & Metrics
  • PDF
  • Tweet Widget
  • Facebook Like
  • Google Plus One

More in this TOC Section

  • Identifying early PAH biomarkers in systemic sclerosis
  • Viable virus aerosol propagation by PAP circuit leak
  • Ambulatory management of secondary spontaneous pneumothorax
Show more Original Articles

Related Articles

Navigate

  • Home
  • Current issue
  • Archive

About the ERJ

  • Journal information
  • Editorial board
  • Reviewers
  • CME
  • Press
  • Permissions and reprints
  • Advertising

The European Respiratory Society

  • Society home
  • myERS
  • Privacy policy
  • Accessibility

ERS publications

  • European Respiratory Journal
  • ERJ Open Research
  • European Respiratory Review
  • Breathe
  • ERS books online
  • ERS Bookshop

Help

  • Feedback

For authors

  • Instructions for authors
  • Publication ethics and malpractice
  • Submit a manuscript

For readers

  • Alerts
  • Subjects
  • Podcasts
  • RSS

Subscriptions

  • Accessing the ERS publications

Contact us

European Respiratory Society
442 Glossop Road
Sheffield S10 2PX
United Kingdom
Tel: +44 114 2672860
Email: journals@ersnet.org

ISSN

Print ISSN:  0903-1936
Online ISSN: 1399-3003

Copyright © 2022 by the European Respiratory Society