Paper
29 July 1993 Automated method for relating regional pulmonary structure and function: integration of dynamic multislice CT and thin-slice high-resolution CT
Jehangir K. Tajik, Steven D. Kugelmass, Eric A. Hoffman
Author Affiliations +
Proceedings Volume 1905, Biomedical Image Processing and Biomedical Visualization; (1993) https://doi.org/10.1117/12.148647
Event: IS&T/SPIE's Symposium on Electronic Imaging: Science and Technology, 1993, San Jose, CA, United States
Abstract
We have developed a method utilizing x-ray CT for relating pulmonary perfusion to global and regional anatomy, allowing for detailed study of structure to function relationships. A thick slice, high temporal resolution mode is used to follow a bolus contrast agent for blood flow evaluation and is fused with a high spatial resolution, thin slice mode to obtain structure- function detail. To aid analysis of blood flow, we have developed a software module, for our image analysis package (VIDA), to produce the combined structure-function image. Color coded images representing blood flow, mean transit time, regional tissue content, regional blood volume, regional air content, etc. are generated and imbedded in the high resolution volume image. A text file containing these values along with a voxel's 3-D coordinates is also generated. User input can be minimized to identifying the location of the pulmonary artery from which the input function to a blood flow model is derived. Any flow model utilizing one input and one output function can be easily added to a user selectable list. We present examples from our physiologic based research findings to demonstrate the strengths of combining dynamic CT and HRCT relative to other scanning modalities to uniquely characterize pulmonary normal and pathophysiology.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jehangir K. Tajik, Steven D. Kugelmass, and Eric A. Hoffman "Automated method for relating regional pulmonary structure and function: integration of dynamic multislice CT and thin-slice high-resolution CT", Proc. SPIE 1905, Biomedical Image Processing and Biomedical Visualization, (29 July 1993); https://doi.org/10.1117/12.148647
Lens.org Logo
CITATIONS
Cited by 20 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood circulation

Lung

Blood

Image segmentation

Tissues

X-ray computed tomography

Scanners

Back to Top