Comparison of the Automated Nonradiometric Bactec MGIT 960 System with Löwenstein-Jensen, Coletsos, and Middlebrook 7H11 Solid Media for Recovery of Mycobacteria

  • Article
  • Published:
European Journal of Clinical Microbiology and Infectious Diseases Aims and scope Submit manuscript

Abstract

 The aim of this study was to evaluate the sensitivity of as well as the time to detection of mycobacteria by three procedures: solid media with traditional reading, microscopy on solid media, and liquid culture using the automated nonradiometric Bactec MGIT 960 system. A total of 2832 respiratory specimens were tested, 315 of which were positive for mycobacteria. The most frequently isolated species was Mycobacterium tuberculosis (201 isolates). One hundred twenty mycobacteria other than tuberculosis were isolated, 72 of which were Mycobacterium xenopi strains. Sensitivity of each of the different media compared to all media combined for growth of Mycobacterium tuberculosis was 93%, 76.1%, 79.6%, and 75.1% for Bactec MGIT 960, Middlebrook 7H11 plates, Löwenstein-Jensen, and Coletsos, respectively. Sensitivity of the Bactec MGIT 960 for detection of all mycobacterial isolates was 75.1%. When this automated system was supplemented with visual inspection, the sensitivity increased to 89.4%. The sensitivity of Middlebrook 7H11 plates, Löwenstein-Jensen, and Coletsos was 50.8%, 60.7%, and 52.3%, respectively. Time to detection of Mycobacterium tuberculosis using the Bactec MGIT 960 system and Middlebrook 7H11 plates with microscopic reading was 12.7 and 13 days, respectively; using the traditional Löwenstein-Jensen and Coletsos media, time to detection was 22.8 and 22.7 days, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Idigoras, P., Beristain, X., Iturzaeta, A. et al. Comparison of the Automated Nonradiometric Bactec MGIT 960 System with Löwenstein-Jensen, Coletsos, and Middlebrook 7H11 Solid Media for Recovery of Mycobacteria. EJCMID 19, 350–354 (2000). https://doi.org/10.1007/s100960050492

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s100960050492

Keywords

Navigation