Table 6—

Sensitivity and specificity estimates for isoniazid

First author [ref.]Sensitivity#Specificity
Bang 160.85 (0.62–0.97)1.00 (0.88–1.00)
Barnard 170.89 (0.83–0.94)1.00 (0.98–1.00)
Hillemann 200.88 (0.81–0.94)1.00 (0.91–1.00)
Hillemann 181.00 (0.80–1.00)1.00 (0.86–1.00)
Hillemann 190.88 (0.78–0.94)1.00 (0.93–1.00)
Hillemann 190.92 (0.83–0.97)1.00 (0.93–1.00)
Hillemann 190.88 (0.74–0.96)1.00 (0.88–1.00)
Hillemann 190.90 (0.77–0.97)1.00 (0.88–1.00)
Weizenegger 151.00 (0.29–1.00)0.98 (0.90–1.00)
Makinen 210.84 (0.67–0.95)1.00 (0.83–1.00)
Miotto 230.67 (0.60–0.74)1.00 (0.89–1.00)
Miotto 231.00 (0.54–1.00)1.00 (0.88–1.00)
Miotto 220.60 (0.26–0.88)0.92 (0.82–0.98)
Miotto 220.73 (0.39–0.94)0.93 (0.83–0.98)
Somoskovi 240.57 (0.46–0.67)1.00 (0.92–1.00)
  • Data are presented as % (confidence interval). #: Chi-squared = 84.93; degrees of freedom = 14 (p<0.001); inconsistency (I-squared) = 83.5%; : Chi-squared = 28.50; degrees of freedom = 14 (p = 0.0122); inconsistency (I-squared) = 50.9%. See also figure 4.