Table 1—

Condensate in the breathing system, mean room temperature and absolute humidification

PatientPressure cmH2OMean room temperature °CWater in mask/tube mLAbsolute humidification# mL
Conventional humidifierControlled heated breathing tube humidifierConventional humidifierControlled heated breathing tube humidifierConventional humidifierControlled heated breathing tube humidifier
1717.311.9340145229
2815.614.0342131136
3814.611.6160130143
41213.614.0632222158
5910.813.629214392
6715.313.654176119
7712.612.9365114154
81016.216.6262151149
91014.616.0402145229
10711.711.1692103138
11811.010.9270120137
12715.412.2132178170
13713.214.7492123134
14714.114.222315385
15713.012.0374113140
16716.315.5351142116
17915.115.072159203
18913.716.1333125200
19715.315.7462116158
Mean±sd8.1±1.414.2±1.813.8±1.835.3±16.01.9±1.3136.3±30.9152.1±40.0
p-value0.520.00010.12
  • #: difference of water in the heating chamber between evening and morning minus water in the mask/tube system. 1 cmH2O = 0.0978 kPa.