TABLE 3

Relative rates of rejection (D or F grade) and mean differences# in rejected values according to reviewers and computerised assessment for healthy subjects and Caucasian adults

Entire datasetFVCFEV1
RejectedΔFVC mLRejectedΔFEV1 mL
  Healthy subjects+
   Reviewer 1  5.2  −351 (−402– −300)  3.1  −312 (−372– −251)
   Computer 25 mL  16.0  −154 (−181– −128)  3.9  −110 (−165– −55)
  Caucasian adults§
   Reviewer 1  3.7  −428 (−591– −265)  2.1  −212 (−383.4– −40.2)
   Reviewer 2  3.8  −167 (−331– −4)  1.9  −92 (266.7–83.6)
   Reviewer 3  5.9  −97 (−233–39)  2.0  −40 (−266.7–83.6)
   Computer 25 mL  11.5  −104 (−191– −16)  3.1  −12 (−191.3– −16.1)
  • Data are presented as % or mean (95% CI). FVC: forced vital capacity; FEV1: forced expiratory volume in 1 s. #: calculated as the mean difference from predicted values observed for tests rejected according to the various types of analysis; : FVC was rejected by the computer (grades D and F) based on the 2005 American Thoracic Society/European Respiratory Society recommendations (i.e. end-of-test did not attain <25 mL for ≥1 s in subjects aged >10 years, if exhalation was <6 s); +: n=7777; §: n=1466.