Incidence and Severity of Hoarseness

 Video stylet (n=20)Direct laryngoscope (n=20)P-value
Incidence5/20 (25%)13/20 (65%)0.025
Severity(0/1/2/3)15/5/0/07/8/4/10.021
  • 0=no , 1=felt by patient, 2=felt by observer, 3=aphonia