ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liu, J.
Right arrow Articles by Thomas, P. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liu, J.
Right arrow Articles by Thomas, P. S.
Eur Respir J 2007; 30:807-808
Copyright ©ERS Journals Ltd 2007

Collection devices influence the constituents of exhaled breath condensate

J. Liu1,2, D. H. Conrad3, S. Chow3, V. H. Tran3, D. H. Yates4 and P. S. Thomas1,2,3

1 Prince of Wales Clinical School, Faculty of Medicine, and 3 School of Medical Sciences, Faculty of Medicine, University of New South Wales, Sydney, and 2 Dept of Respiratory Medicine, Prince of Wales Hospital, Randwick, and 4 Dept of Thoracic Medicine, St Vincent's Hospital, Darlinghurst, New South Wales, Australia.

To the Editors:

The recent paper by Rosias et al. 1 reported that silicone and glass inner coatings were superior to the EcoScreen® system (Erich Jaeger GmbH, Hochberg, Germany), aluminium, polypropylene and Teflon when measuring 8-isoprostane and albumin levels in exhaled breath condensate (EBC) 13. This raises important issues in the ongoing debate about the optimal collection method for sampling airway biomarkers. We have complemented these important data by comparing the efficiency and reproducibility of EBC biomarkers collected by different devices in six healthy subjects.

Four collection systems were compared in a randomised order: glass, siliconised glass, EcoScreen® and RTube® (Respiratory Research Inc., Charlottesville, VA, USA). Oxides of nitrogen (NOx), total protein, mucin and pH were measured and assessed for reproducibility over 3 days 4, 5.

The mean±SD EBC NOx level after a 10-min collection period was significantly higher using the EcoScreen® (25.7±9.1 nmol) than either siliconised glass (3.0±0.7 nmol) or RTube® (3.7±0.7 nmol; p<0.001; fig. 1aGo). Total protein per 10-min collection was significantly higher using the EcoScreen® (18.6±7.3 µg) than either glass (6.6±3.3 µg) or RTube® (7.0±2.9 µg; p = 0.017; fig. 1bGo). Siliconised glass tubes showed a trend in their ability to collect more total protein in EBC compared with glass tubes; a larger sample size may have shown a significant difference (n = 107, {alpha} = 0.05, 1-ß = 0.8). Mucin levels in EBC were not significantly different between the four devices (p = 0.52). No significant difference was found in pH in EBC between the four devices (p = 0.34, Friedman test). EBC collection was more efficient in the EcoScreen® (21.8±2.4 µL·L–1 of breath) than the siliconised glass tubes (12.8±1.9 µL·L–1 of breath; p<0.05) or RTube® (12.9±1.1 µL·L–1 of breath; p<0.05; fig. 1cGo).


Figure 1
View larger version (7K):
[in this window]
[in a new window]

 
Fig. 1— a) The total amount of oxides of nitrogen (NOx) and b) the total protein levels in exhaled breath condensate (EBC) during a 10-min collection. c) The EBC volume per total breath volume. a) Total of NOx was significantly higher in the samples collected using the EcoScreen® system (Erich Jaeger GmbH, Hochberg, Germany) when compared with either siliconised glass tubes or the RTube® (Respiratory Research Inc., Charlottesville, VA, USA) but did not differ significantly from the amounts collected by the glass tube apparatus. b) The total protein levels in EBC during 10-min EBC collection were significantly higher in the samples collected using EcoScreen® when compared with either glass tubes or RTube® (p = 0.017). c) The mean EBC volume per total breath volume collected using EcoScreen® was significantly higher than those collected by either siliconised tube or RTube® (p = 0.010). *: p<0.05.

 
NOx levels were poorly reproducible and the median coefficient of variation for NOx concentrations was lowest in the EBC collected by the siliconised glass tube (16.1%), although there was a large range (0.0–67.4%). It has been demonstrated that NOx stability is associated with temperature, which may explain the relatively large coefficient of variation of NOx using the RTube® 6, in which the temperature gradually increases from -15°C to room or body temperature. The RTube® might be better used for monitoring markers not affected by collecting temperature. The EcoScreen® seemed to have better reproducibility in terms of total protein levels in EBC, although there was no significant difference when compared with glass, siliconised glass or the RTube®. pH was the most reproducible marker in all devices.

To determine whether the devices could contaminate samples with NOx or H+ ions, distilled water, tap water and normal saline were incubated in each device. Baseline median (range) NOx levels were 1.2 (1.0–2.2) µM, 10.9 (10.1–11.4) µM and 1.2 (0.5–1.7) µM in distilled water, tap water and normal saline, respectively. NOx levels were significantly increased in the EcoScreen® system (5.4 (2.2–7.3) µM in distilled water, 14.9 (14.3–19.8) µM in tap water and 4.4 (2.4–5.9) µM in normal saline (p = 0.006)) and in the RTube® (2.7 (1.4–4.3) µM in distilled water, 11.5 (11.1–11.8) µM in tap water and 2.6 (1.2–3.9) µM in normal saline (p = 0.006)) after a 10-min incubation; there was no significant change in NOx levels in either glass tubes or siliconised glass tubes. No significant change was found in pH levels after 10 min of incubation in any device.

This study has confirmed that EBC collection devices influence the efficiency of collection but can also introduce errors in the measurement of markers. The EBC collected using the EcoScreen® system had the largest amount of NOx but also demonstrated poor inter-day and intra-day reproducibility. The higher efficiency of the EcoScreen® system in trapping the NO degradation product, NOx, confirms our previous study 7, but is factitious and represents a contribution of NOx from the device to aqueous media.

The EcoScreen® system had the highest amount of total protein levels in EBC compared with either the glass tube or the RTube® and it also showed superior inter-day repeatability in total protein in this study. Higher protein levels in EBC collected by the most efficient device will aid identification quantification of EBC proteins, which may be near the lower limit of detection.

Mean total mucin levels in EBC were not significantly different between the four devices. In addition, glass and siliconised tubes had a trend to better reproducibility compared with the other two types of apparatus. An explanation may be that like other proteins, mucin is negatively charged and repulsed by glass, which also has a negative net charge 8.

In conclusion, collection devices significantly affect exhaled breath condensate biomarker levels and absolute values from different devices are not directly comparable. Siliconised glass showed the least variability in oxides of nitrogen levels, whilst the EcoScreen® was more consistent and efficient for protein collection, and also in terms of total exhaled breath condensate volume. This efficiency may in part be related to the lower temperature used in this device. We conclude that no single device is ideal for all applications. In future studies, each marker may need to be tested in a variety of devices to determine the optimal collection apparatus.

ACKNOWLEDGEMENTS

We would like to thank Ratnawati (University of New South Wales, Sydney, New South Wales, Australia), A. Krishnan and G. Warwick (both St Vincent's Hospital, Darlinghurst, New South Wales, Australia) for their assistance in this study.

REFERENCES

  1. Rosias PP, Robroeks CM, Niemarkt HJ, et al. Breath condenser coatings affect measurement of biomarkers in exhaled breath condensate. Eur Respir J 2006;28:1036–1041.[Abstract/Free Full Text]
  2. Rosias PPR, Vernooy JHJ, Dentener MA, et al. The inner coating of condenser systems influences the detection of human albumin in exhaled breath condensate. Eur Respir J 2003;22: Suppl. 45 280s[CrossRef]
  3. Rosias P, Robroeks C, Hendriks J, Dompeling E, Jobsis Q. Exhaled breath condensate: a space odessey, where no one has gone before. Eur Respir J 2004;24:189–190.[Free Full Text]
  4. Liu J, Thomas PS. Relationship between exhaled breath condensate volume and measurements of lung volumes. Respiration 2007;74:142–145.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  5. Jackson AS, Sandrini A, Campbell C, Chow S, Thomas PS, Yates DH. Comparison of biomarkers in exhaled breath condensate and broncho-alveolar lavage. Am J Respir Crit Care Med 2007;175:222–227.[Abstract/Free Full Text]
  6. Yang F, Troncy E, Vinet B, Vinay P, Czaika G, Blaise G. Effects of reducing reagents and temperature on conversion of nitrite and nitrate to nitric oxide and detection of NO by chemiluminescence. Clin Chem 1997;43:657–662.[Abstract/Free Full Text]
  7. Liu J, Chow S. Ratnawati, et al.. Effect of collection materials upon markers of inflammation in exhaled breath condensate (abstract). Respirology 2006;11:A31
  8. Van Klinken BJ, Dekker J, Buller HA, Einerhand AW. Mucin gene structure and expression: protection vs adhesion. Am J Physiol 1995;269:G613–G627.[Web of Science][Medline] [Order article via Infotrieve]



This article has been cited by other articles:


Home page
Eur Respir JHome page
I. Horvath, Z. Lazar, N. Gyulai, M. Kollai, and G. Losonczy
Exhaled biomarkers in lung cancer
Eur. Respir. J., July 1, 2009; 34(1): 261 - 275.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
S. Chow, D. H. Yates, and P. S. Thomas
Reproducibility of exhaled breath condensate markers
Eur. Respir. J., October 1, 2008; 32(4): 1124 - 1126.
[Full Text] [PDF]


Home page
Eur Respir JHome page
D. L. Bayley, H. Abusriwil, A. Ahmad, and R. A. Stockley
Validation of assays for inflammatory mediators in exhaled breath condensate
Eur. Respir. J., May 1, 2008; 31(5): 943 - 948.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
P. P. R. Rosias, Q. Jobsis, K. van de Kant, C. Robroeks, C. P. van Schayck, L. J. I. Zimmermann, and E. Dompeling
Global condensation: a "climate change" towards better standardisation of exhaled breath condensate measurements
Eur. Respir. J., March 1, 2008; 31(3): 684 - 685.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liu, J.
Right arrow Articles by Thomas, P. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liu, J.
Right arrow Articles by Thomas, P. S.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS