ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boffi, R.
Right arrow Articles by Invernizzi, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boffi, R.
Right arrow Articles by Invernizzi, G.
Eur Respir J 2006; 27:862-863
Copyright ©ERS Journals Ltd 2006

A day at the European Respiratory Society Congress: passive smoking influences both outdoor and indoor air quality

R. Boffi1, A. Ruprecht1, R. Mazza1, M. Ketzel2 and G. Invernizzi1

1 Tobacco Control Unit, National Cancer Institute/SIMG-Italian College of GPs, Milan, Italy, and 2 National Environmental Research Institute, Roskilde, Denmark.

To the Editors:

Outdoor and indoor air quality is a well known determinant of human health 1. Environmental tobacco smoke (ETS) is a recognised risk factor for respiratory diseases 2 and the most important source of indoor particulate matter (PM) pollution 3. In recent years, several countries have issued smoking policy rules to protect nonsmoking people from ETS with a good compliance 4. This year, the European Respiratory Society (ERS) Congress was held in Copenhagen (Denmark), a country where, like many others, comprehensive anti-smoking rules are not yet fully endorsed 5. In fact, although smoking has been restricted in state-owned governmental premises since 1988, the legislation doesn't apply to the hospitality industry or to workplaces in the private sector. The ERS has made the case of passive smoking one of utmost importance for respiratory prevention 6. Congress participants were advised to refrain from smoking both inside and in front of the Copenhagen Congress venue at the Bella Center, which was indicated by signs stating the following: "Tobacco is the major cause of lung disease. Please refrain from smoking in and in front of the Congress venue, including meeting rooms, the exhibition, poster areas, restrooms, restaurants and bars." The ERS Congress represented a good opportunity for air quality measurement and comparisons in relation to ETS pollution. PM2.5, as a representative marker of outdoor pollution 1 and as a surrogate of ETS 7, was measured in different places in the city, in the proximity of the Bella Center and inside the Bella Center, and compared with official 24-h urban backgrounds.

PM2.5 measurements were carried out on the third day of the Congress (September 17, 2005) from the morning to late in the evening with time-tabled records of the place of measurements. We measured PM concentrations sequentially in the Congress car parking place (open space), inside the Bella Center, outdoors in front of the Bella Center with smokers under a roof (18 smokers during a measurement time of 35 min), along the motorway to the city centre, and inside a Copenhagen restaurant where smoking was allowed. Official outdoor PM2.5 values for the same day were taken for comparison from an urban background location in Copenhagen (H.C. Ørsted Institute) belonging to the Danish Air Quality Monitoring Programme 8.

PM2.5 measurements were carried out by means of model AEROCET 531 (Metone Instruments Inc., Grants Pass, OR, USA), a hand-held laser-operated monitor of particle size and mass concentration with a 2-min sampling time. The instrument had been pre-calibrated using a reference gravimetric system. The weather was cloudy and with a light breeze, with the temperature ranging 17–27°C and the relative humidity 44–74%. For each site, a minimum of eight consecutive measurements for a total of 16 min were taken. US-EPA air quality index (AQI) was chosen as a reference 9. The official outdoor PM2.5 values at the urban background location were measured with TEOM technology (Tapered-Element Oscillating Microbalance; Rupprecht & Patashnick Co. Inc., Albany, NY, USA).

Mean±SEM PM2.5 records are reported in figure 1Go. With reference to time-sequence of measurements, PM2.5 complied with good AQI according to US-EPA (<12.5 µg·m–3) in the car parking area and inside the Bella Center, with a level of 6.0±1.7 and 3.0±0.9 µg·m–3, respectively. Peak values were 12.5 µg·m–3 and 12.0 µg·m–3, respectively. However, outside in front of the Bella Center with smokers, mean PM2.5 was 17.8±7.5 µg·m–3 with a peak of 98.9 µg·m–3 (p<0.03, as compared with inside the venue), which is a step down in AQI. PM2.5 along the motorway was only 4.6±0.7 µg·m–3 with a peak value of 8.7 µg·m–3. Inside the restaurant, high concentrations of PM2.5 were found (165.1±8.5 µg·m–3) with a peak value of 372.2 µg·m–3, with a "very unhealthy" AQI. Official outdoor PM2.5 mean±SEM recorded in the town for the time interval of all the measurements was 5.7±0.4 µg·m–3. Overall, mean values observed with smokers in front of the Bella Center and inside the restaurant were significantly higher than the outdoor parking place, indoor Bella Center, motorway and Copenhagen outdoor official data (p<0.05 and p<0.001, respectively).


Figure 1
View larger version (13K):
[in this window]
[in a new window]
 
Fig. 1— Comparison of particulate matter (PM2.5) concentrations at different sites during the third day of the European Respiratory Society Copenhagen Congress, 2005. ···: air quality index break-points, which correspond to; 5: very unhealthy; 4: unhealthy; 3: unhealthy for sensitive groups; 2: moderate; 1: good. *: p<0.05 as compared with outdoor, indoor, motorway and official mean; **: p<0.001 as compared with outdoor, indoor, motorway and official mean.

 
Indoor and outdoor air quality monitoring through an entire day showed that in a country where outdoor air quality is generally good, as in Denmark, the presence of ETS worsens both indoor and outdoor PM concentrations. In the restaurant with smokers we observed very high PM2.5 levels, with an AIQ classified as "very unhealthy", as reported by previous studies 7. PM also reached significant values outdoors where smokers gathered to smoke, confirming previous field surveys at outdoor patios 10. By appreciating this issue, ERS organisers advised participants not to smoke in front of the Congress venue, a suggestion that also implies coherence with doctor's role model, an issue that still deserves attention.

Understanding the importance of indoor versus outdoor pollution and the issue of environmental tobacco smoke as both an indoor and outdoor pollutant can contribute to a better knowledge of environmental tobacco smoke exposure risk.

ACKNOWLEDGEMENTS

The authors are grateful to G. Viegi for his helpful discussion.

REFERENCES

  1. Kunzli N. The public health relevance of air pollution abatement. Eur Respir J 2002;20:198–209.[Abstract/Free Full Text]
  2. Viegi G, Simoni M, Scognamiglio A, et al. Indoor air pollution and airway disease. Int J Tuberc Lung Dis 2004;8:1401–1415.[ISI][Medline] [Order article via Infotrieve]
  3. Repace JL, Lowrey AH. Indoor air pollution, tobacco smoke, and public health. Science 1980;208:464–472.[Abstract/Free Full Text]
  4. Gallus S, Zuccaro P, Colombo P, et al. Effects of new smoking regulations in Italy. Ann Oncol 2006;17:346–347.[Abstract/Free Full Text]
  5. Denmark Law about Smoke-free Environments on Public Premises; means of transportation and the like. Law nr.436 of 06/01/1995. Available online: http://apps.nccd.cdc.gov/nations/legislation/TextFiles/Denmark_13.htm. Date last accessed: December 2005. Date last updated: November 2005
  6. Smoke Free Europe Conference 2005. http://www.ersnet.org/ers/lr/browse/default.aspx?id_dossier=31552. Date last accessed: December 2005. Date last updated: December 2005
  7. Invernizzi G, Ruprecht A, Mazza R, et al. Real-time measurement of indoor particulate matter originating from environmental tobacco smoke: a pilot study. Epidemiol Prev 2002;26:2–6.[Medline] [Order article via Infotrieve]
  8. Kemp K, Ellermann T, Palmgren F, Wåhlin P, Berkowicz R. Jørgen Brandt 2005: The Danish Air Quality Monitoring Programme. Annual summary for 2004. National Environmental Research Institute (NERI), Roskilde Denmark. NERI Technical Report No. 544. Link for report: http:\\technical-reports.dmu.dk. Link for recent data: http://www.dmu.dk/atmosphericenvironment/byer/forside.htm. Date last accessed: December 2005. Date last updated: December 2005
  9. Guideline for reporting of daily air quality-air quality index (AQI). United States Office of Air Quality EPA-454/R-99-010 Environmental Protection Planning and Standards July 1999
  10. Repace J. Measurements of outdoor air pollution from secondhand smoke on the UMBC campus. http://www.repace.com/pdf/outdoorair.pdf. Date last accessed: December 2005. Date last updated: November 2005




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boffi, R.
Right arrow Articles by Invernizzi, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boffi, R.
Right arrow Articles by Invernizzi, G.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS