ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vandevoorde, J.
Right arrow Articles by Vincken, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vandevoorde, J.
Right arrow Articles by Vincken, W.
Eur Respir J 2006; 27:378-383
Copyright ©ERS Journals Ltd 2006

Obstructive and restrictive spirometric patterns: fixed cut-offs for FEV1/FEV6 and FEV6

J. Vandevoorde1, S. Verbanck2, D. Schuermans2, J. Kartounian1 and W. Vincken2

1 Dept of General Practice and, 2 Respiratory Division, Academic Hospital, University of Brussels, Brussels, Belgium.

CORRESPONDENCE: J. Vandevoorde, University of Brussels (Vrije Universiteit Brussel), Dept of General Practice, Laarbeeklaan 103, B-1090 Brussels, Belgium. Fax: 32 52373311. E-mail: Jan.Vandevoorde{at}vub.ac.be

Keywords: Chronic obstructive pulmonary disease, forced expiratory volume in six seconds, pulmonary function testing, spirometry

Received: March 25, 2005
Accepted September 8, 2005


    ABSTRACT
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 REFERENCES
 
The purpose of this study was to determine fixed cut-off points for forced expiratory volume in one second (FEV1)/FEV6 and FEV6 as an alternative for FEV1/forced vital capacity (FVC) and FVC in the detection of obstructive and restrictive spirometric patterns, respectively.

For the study, a total of 11,676 spirometric examinations, which took place on Caucasian subjects aged between 20–80 yrs, were analysed. Receiver–operator characteristic curves were used to determine the FEV1/FEV6 ratio and FEV6 value that corresponded to the optimal combination of sensitivity and specificity, compared with the commonly used fixed cut-off term for FEV1/FVC and FVC.

The data from the current study indicate that FEV1/ FEV6 <73% and FEV6 <82% predicted can be used as a valid alternative for the FEV1/FVC <70% and FVC <80% pred cut-off points for the detection of obstruction and restriction, respectively. The statistical analysis demonstrated very good, overall, agreement between the two categorisation schemes. For the spirometric diagnosis of airway obstruction (prevalence of 45.9%), FEV1/FEV6 sensitivity and specificity were 94.4 and 93.3%, respectively; the positive and negative predictive values were 92.2 and 95.2%, respectively. For the spirometric detection of a restrictive pattern (prevalence of 14.9%), FEV6 sensitivity and specificity were 95.9 and 98.6%, respectively; the positive and negative predictive values were 92.2 and 99.3%, respectively.

This study demonstrates that forced expiratory volume in one second/forced expiratory volume in six seconds <73% and forced expiratory volume in six seconds <82% predicted, can be used as valid alternatives to forced expiratory volume in one second/forced vital capacity <70% and forced vital capacity <80% predicted, as fixed cut-off terms for the detection of an obstructive or restrictive spirometric pattern in adults.

Spirometry is the most frequently performed pulmonary function test and is an essential tool for the diagnosis and follow-up of respiratory diseases. Handheld office spirometers are now widely available for use in primary care and improvements in spirometry software have resulted in access to improved spirometric tests. Several studies emphasised the importance of spirometry in primary care, as a screening tool for the early detection of chronic obstructive pulmonary disease (COPD) 14. This has resulted in the need for easy-to-perform spirometry tests. Increasing evidence showed that the forced expiratory volume in six seconds (FEV6) 5, can be used as a convenient alternative for forced vital capacity (FVC) 69. The use of six seconds expiratory manoeuvres makes office spirometry easier and faster, providing a more explicit end-of-test definition and reduces the risk of syncope 10.

An important issue in spirometry is the definition of abnormality. The American Thoracic Society and the European Respiratory Society (ERS) guidelines recommend the use of reference equations, derived from a representative sample of healthy subjects, to determine lower limits of normal (LLN) 11, 12, taking into account that the spirometric indices are influenced by age, height, sex and ethnicity. It has already been demonstrated that FEV1/FEV6 is a valid alternative for FEV1/FVC when using LLN based on the third National Health and Nutrition Examination Survey (NHANES III) reference equations 6, 7, 9. At present, spirometers, and in particular handheld spirometers, do not always provide reference equation-based LLN. Moreover, reference equations for FEV6 and FEV1/FEV6 are only available for the USA population (NHANES III survey) 13 and only recently for European subjects in the 65–85-yrs category 14. Adding to the complexity of the problem, reference equations obtained from different studies lead to significant differences in predicted FVC and FEV1 15.

Presently, it is common practice to determine airway obstruction by use of a fixed cut-off point, i.e. when FEV1/FVC is <70%, according to the Guidelines from the Global Initiative for Chronic Obstructive Lung Disease (GOLD) 16.The aim of this study is to determine an alternative for the fixed cut-off points of FEV1/FVC <70% and FVC <80% predicted suitable for the use of FEV1/FEV6 and FEV6, respectively.


    METHODS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 REFERENCES
 
The data of consecutive adult patients, referred to the lung function laboratory of the Academic Hospital of the University of Brussels (AZ-VUB, Brussels, Belgium), between February 1992 and December 2000, were analysed. Spirometry measurements were performed with a mass-flow sensor (SensorMedics model 2200, Viasys Health Care, Yorba Linda, CA, USA), by highly trained and experienced pulmonary function technicians, according to the guidelines of the ERS 12.

For the diagnosis of airway obstruction, FEV1/FVC <70% was used as a fixed cut-off point, according to the GOLD guidelines 16. From a receiver–operator characteristic (ROC) curve, the FEV1/FEV6 ratio, that corresponded to the optimal combination of sensitivity and specificity (i.e. the greatest sum of both), was determined.

A subject was said to have a restrictive spirometric pattern if there was a reduced FVC in the presence of a normal FEV1/FVC. A fixed cut-off of 80% of the predicted value for FVC was used as the "gold standard". The FEV6 value that corresponded to the optimal combination of sensitivity and specificity was determined from a ROC curve.

To calculate sensitivity and specificity for FEV1/FEV6 and FEV6 as a predictor for obstruction or a restrictive spirometric pattern, 2x2 tables were used. For both indices the positive predictive value (PPV) and the negative predictive value (NPV) were also calculated. The PPV represents the proportion of patients with abnormal test results who have the disease and the NPV represents the proportion of patients with normal test results who do not have the disease. Furthermore, in each analysis the discordant cases, i.e. false positives and false negatives, were scrutinised.

Finally, agreement between the two categorisation schemes, based either on FVC or on FEV6, was assessed using kappa statistics: the number of obstructive patients were determined using FEV1/FVC <70% as a fixed cut-off point. In the nonobstructive patients, a restrictive spirometric pattern was considered if FVC <80% of the predicted value. Similarly, the cut-offs, obtained by a ROC curve for FEV1/FEV6 and FEV6, were used as a fixed cut-off to determine the number of patients with a normal, obstructive or restrictive spirometric pattern. The resulting classifications, based on either FVC- or FEV6-related indices, were combined in a 3x3 table, and a kappa value was calculated. Kappa represents the agreement between the two categorisation schemes in excess of the amount of agreement that would be expected by chance.


    RESULTS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 REFERENCES
 
The same study population was used as in a previous study, by the current authors 9, comparing FEV6 and FVC using LLN determined with the NHANES III reference equations 13. Spirometric data from 11,676 Caucasian subjects were studied, of whom 7,010 (60%) were male and 4,666 (40%) were female. Subject characteristics are shown in table 1Go. In this table, FEV1/FVC <70% and FVC <80% pred were used for the diagnosis of obstruction and a restrictive pattern, respectively.


View this table:
[in this window]
[in a new window]
 
Table 1— Subject demographics, presence and severity of airway obstruction

 
The obstructive group was further classified into subgroups according to the severity of airway obstruction in accordance with the GOLD guidelines 16: FEV1/FVC <70%, in combination with FEV1 ≥80% pred (Stage I), or 50%≤FEV1<80% pred (Stage II), or 30%≤FEV1<50% pred (Stage III), or FEV1 ≤30% pred (Stage IV).

Spirometric diagnosis of obstruction
Considering FEV1/FVC <70% as being the ‘gold standard’ for obstruction, a ROC curve was used to determine the best corresponding cut-off for FEV1/FEV6 (fig. 1Go). The area under the ROC curve was 98.8% (95% confidence interval (CI): 98.6–98.9%), and the FEV1/FEV6 cut-off, corresponding to the greatest sum of sensitivity and specificity, was 73%. When using a FEV1/FEV6 cut-off of 76%, sensitivity reached 100%, but specificity dropped to 71.7%. Choosing a fixed cut-off of FEV1/FEV6 <70% resulted in a specificity of 100%, with a sensitivity of 84.4%. Table 2Go shows the sensitivity and specificity results using FEV1/FEV6 <73% as a fixed cut-off. For the total population, FEV1/FEV6 sensitivity and specificity were 94.4 and 93.3%, respectively. The PPV and NPV were 92.2 and 95.2%, respectively. The prevalence of obstruction was 45.9%. Similar results were obtained when considering male and female subjects separately (data not shown).


Figure 1
View larger version (7K):
[in this window]
[in a new window]
 
Fig. 1— Receiver–operator characteristic curve for forced expiratory volume in one second (FEV1)/FEV6 using FEV1/forced vital capacity <70% as a "gold standard" for obstruction.

 

View this table:
[in this window]
[in a new window]
 
Table 2— Comparison of forced expiratory volume in one second(FEV1)/FEV6 with FEV1/forced vital capacity (FVC) for the diagnosis of airway obstruction

 
Analysis of the 726 discordant cases (false positives and false negatives combined) showed that 98.8% of the discordant values of FEV1/FEV6 are within a ±5% interval of the chosen fixed cut-off of 73%. Only one subject was found to have a FEV1/FEV6 which differed by >10% from the cut-off.

In the 426 false positive cases, the mean difference of FEV1/FVC and FEV1/FEV6, with their respective LLN, was 0.9 (SD = 1.0) and –2.1% (SD = 1.0 %). In the 300 false negative cases the mean difference of FEV1/FVC and FEV1/FEV6 with their respective LLN was -3.6 (SD = 2.6) and 1.5% (SD = 2.0%).

Spirometric detection of restriction
In all subjects with normal FEV1/FVC (n = 6,319), FVC <80% pred was considered as a ‘gold standard’ for the detection of a restrictive spirometric pattern. A ROC analysis showed that a fixed cut-off of FEV6 <82% pred resulted in the best combination (i.e. greatest sum) of sensitivity and specificity (fig. 2Go). The area under the ROC curve was 99.5% (95% CI = 99.5–99.6%). When using FEV6 <84% pred, sensitivity reached 100% with a specificity of 95.5%. Choosing FEV6 <80% resulted in a specificity of 100%, but sensitivity dropped to 88%. Table 3Go shows the current findings using FEV6 <82% pred as a fixed cut-off. For the total population, sensitivity and specificity was 95.9 and 98.6%, respectively. The PPV was 92.2% and the NPV 99.3%. The prevalence of a restrictive pattern was 14.9%. Similar results were obtained for both male and female populations (data not shown).


Figure 2
View larger version (7K):
[in this window]
[in a new window]
 
Fig. 2— Receiver–operator characteristic curve for forced expiratory volume in six seconds using forced vital capacity <80% predicted as a "gold standard" for restriction.

 

View this table:
[in this window]
[in a new window]
 
Table 3— Comparison of forced expiratory volume in six seconds(FEV6) with forced vital capacity (FVC) for the diagnosis of a spirometric restrictive pattern: in the nonobstructive group

 
Analysis of the 116 discordant cases (false positives and false negatives combined) showed that 94.0% of the discordant values of FEV6 are within a ±5% interval of the chosen fixed cut-off of 82% pred. None of these results differed by >10% with the cut-off (data not shown).

In the 77 false positive cases, the mean difference of FVC and FEV6, with their respective cut-offs, was 1.1 (SD = 1.4) and –2.5% (SD = 1.6%). In the 39 false negative cases, the mean difference of FVC and FEV6 with their respective cut-off was –1.8 (SD = 0.8) and 0.5% (SD = 0.7%).

Overall agreement using kappa statistics
Overall agreement between the two categorisation schemes was assessed using kappa statistics (table 4Go). In this study, a kappa value of 0.87 (95% CI = 0.86–0.88) was obtained, indicating a very good agreement between FEV6- and FVC-derived indices.


View this table:
[in this window]
[in a new window]
 
Table 4— Kappa statistics comparing forced expiratory volume in six seconds(FEV6) and forced vital capacity (FVC) derived indices

 

    DISCUSSION
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 REFERENCES
 
It has already been demonstrated that FEV6 is a reliable alternative for FVC to identify obstructive and restrictive spirometric patterns, using the NHANES III reference equations to calculate LLN for each spirometric index 79. The main purpose of the present study was to determine a fixed cut-off for the FEV1/FEV6 ratio and for the FEV6 which are equivalent to the commonly used fixed cut-offs for the FEV1/FVC ratio and for the FVC.

Indeed, with a kappa value of 0.87, a very good overall performance was obtained for FEV1/FEV6 <73% and FEV6 <82% pred as fixed cut-offs for the detection of obstructive and restrictive spirometric patterns, respectively (table 4Go). A kappa value of 1 indicates perfect agreement, while a kappa value of 0 indicates that agreement is no better than chance. Landis and Koch 17 have proposed the following as standards for strength of agreement for the kappa coefficient: 0.01–0.20 = slight, 0.21–0.40 = fair, 0.41–0.60 = moderate, 0.61–0.80 = substantial and 0.81–1 = almost perfect agreement.

Spirometric diagnosis of obstruction
A ROC curve analysis showed that FEV1/FEV6 <73% was the cut-off with the best combination of sensitivity and specificity, and performed well as a surrogate for FEV1/FVC <70% (table 2Go). In addition, almost all of the discordant cases were close to the cut-off value.

The findings of the present study apply to a population with an overall prevalence of airway obstruction of 45.9%, which corresponds to reported prevalences of COPD of 30–50% in high-risk populations, i.e. smokers aged >45 yrs and subjects with respiratory symptoms. This makes FEV1/FEV6 suitable for screening purposes in primary care.

It should be emphasised that fixed cut-off values should be used with caution, as spirometric indices are highly influenced by age, height, sex and race. From the NHANES III survey, reference equations have become available to calculate predictive values and LLN for FEV1, FVC, FEV6, FEV1/FVC and FEV1/FEV6, with age and height as predictor variables 13. In the study by Hankinson et al. 13, the analysis was performed separately for each sex and each ethnic group, and the LLN was estimated as predicted minus 1.645 times the standard error of the estimate, which corresponds to the fifth percentile.

While fixed cut-off values are more widely used, in an attempt to simplify the diagnosis, there is potential for misclassification. For example, in elderly subjects, where the age-related decline in FEV1/FVC and FEV1/FEV6 may cause a significant over-diagnosis of airway obstruction, pointed out by Hardie et al. 18. This is illustrated here by table 5Go where LLN values, derived from the NHANES III reference equations, are depicted for discrete ages between 20–80 yrs. Clearly, fixed cut-offs of FEV1/FVC <70% and FEV1/FEV6 <73% are most suitable for use with middle-aged subjects. Table 5Go also shows that cut-offs could be 7% (for FEV1/FVC) or 5% (for FEV1/FEV6) higher in 20-yr-old females and 8% (for FEV1/FVC) or 6% (for FEV1/FEV6) lower in 80-yr-old males. Finally, it must be considered that, regardless of the method used to define abnormality, measured values that lie close to the threshold should be interpreted with caution, due to several sources of variability: 1) diurnal and day-to-day variations of spirometric indices 11; 2) between-manoeuvre repeatability criteria that allow for a difference up to a maximum of 0.150 L between the two largest values of both FEV1 and FVC 5; 3) patients with obstruction having coefficients of variation for FEV1 and FVC that are approximately twice those of normal subjects 19.


View this table:
[in this window]
[in a new window]
 
Table 5— Age and sex dependency of the lower limits of normal(LLN)# for forced expiratory volume in one second (FEV1)/forced vital capacity (FVC) and FEV1/FEV6

 
Spirometric detection of restriction
The present study shows that the commonly used cut-off value, FVC <80% predicted, could be replaced by FEV6 <82% pred, especially for excluding a restrictive ventilatory defect. However, a restrictive abnormality is characterised by a reduced total lung capacity, whereas a reduced FVC in the presence of a normal FEV1/FVC can only be used to suggest, but not to diagnose, the presence of a restrictive abnormality 11. A study by Swanney et al. 8 showed that spirometry-based algorithms could not reliably predict a reduced total lung capacity, but are very useful at excluding a restrictive defect. They also demonstrated that FEV6 was equivalent to FVC when using LLN calculated with the NHANES III reference equations. In the current study high, negative predictive values were found when comparing FEV6 and FVC as a predictor of a restrictive pattern (table 3Go). This makes the use of FEV6 suitable for the exclusion of restriction.

However, fixed percentages of the predicted value should be used with caution. Tables 6Go and 7Go show the age and height dependency of the LLN for FVC and FEV6, using the NHANES III reference equations, for males and females. Using fixed cut-offs had a tendency towards over-diagnosis of a restrictive pattern in elderly people.


View this table:
[in this window]
[in a new window]
 
Table 6— Age and height dependency of the lower limits of normal(LLN)# of forced vital capacity (FVC) and forced expiratory volume in six seconds (FEV6) in males

 

View this table:
[in this window]
[in a new window]
 
Table 7— Age and height dependency of the lower limits of normal(LLN)# of forced vital capacity (FVC) and forced expiratory volume in six seconds (FEV6) in females

 

    CONCLUSION
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 REFERENCES
 
This study demonstrates that forced expiratory volume in one second/forced expiratory volume in six seconds <73% and forced expiratory volume in six seconds <82% pred can be used as a valid alternative for forced expiratory volume in one second/forced vital capacity <70% and forced vital capacity <80% pred as fixed cut-off points for the detection of an obstructive or restrictive spirometric pattern in adults. The authors emphasise that the fixed cut-off terms should be used with caution, particularly outside the middle-aged population. Ideally, abnormalities in spirometric values should be defined using lower limits of normal, derived from a representative sample of healthy subjects.


    FOOTNOTES
 
For editorial comments see page 245. Back


    REFERENCES
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 REFERENCES
 

  1. Buffels J, Degryse J, Heyrman J, Decramer M. Office spirometry significantly improves early detection of COPD in general practice. The DIDASCO Study. Chest 2004;125:1394–1399.[Abstract/Free Full Text]
  2. Lundbäck B, Lindberg A, Lindström M, et al. Not 15 but 50% of smokers develop COPD? Report from the Obstructive Lung Disease in Northern Sweden Studies. Respir Med 2003;97:115–122.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  3. Stratelis G, Jakobsson P, Molstad S, Zetterstrom O. Early detection of COPD in primary care: screening by invitation of smokers aged 40 to 55 years. Br J Gen Pract 2004;54:201–206.[Medline] [Order article via Infotrieve]
  4. Zieliñski J, Bednarek M. Early Detection of COPD in a high-risk population using spirometric screening. Chest 2001;119:731–736.[Abstract/Free Full Text]
  5. Miller MR, Hankinson JL, Brusasco V, et al. Standardisation of spirometry. Eur Respir J 2005;26:319–338.[Abstract/Free Full Text]
  6. Enright PL, Connett JE, Bailey WC. The FEV1/FEV6 predicts lung function decline in adult smokers. Respir Med 2002;96:444–449.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  7. Swanney MP, Jensen RL, Crichton DA, Beckert LE, Cardno LA, Crapo RO. FEV6 is an acceptable surrogate for FVC in the spirometric diagnosis of airway obstruction and restriction. Am J Respir Crit Care Med 2000;162:917–919.[Abstract/Free Full Text]
  8. Swanney MP, Beckert LE, Frampton CM, Wallace LA, Jensen RL, Crapo RO. Validity of the American Thoracic Society and other spirometric algorithms using FVC and forced expiratory volume at 6 s for predicting a reduced total lung capacity. Chest 2004;26:1861–1866.
  9. Vandevoorde J, Verbanck S, Schuermans D, Kartounian J, Vincken W. FEV1/FEV6 and FEV6 as an alternative for FEV1/FVC and FVC in the spirometric detection of airway obstruction and restriction. Chest 2005;127:1560–1564.[Abstract/Free Full Text]
  10. Ferguson GT, Enright PL, Buist AS, Higgins MW. Office spirometry for lung health assessment in adults: a consensus statement from the National Lung Health Education Program. Chest 2000;117:1146–1161.[Abstract/Free Full Text]
  11. Medical Section of the American Lung Association. Lung function testing: selection of reference values and interpretative strategies. Am Rev Respir Dis 1991;144:1202–1218.[Web of Science][Medline] [Order article via Infotrieve]
  12. Quanjer PhH, Tammeling GJ, Cotes JE, Pedersen OF, Peslin R, Yernault JC. Standardized lung function testing. Lung volumes and forced ventilatory flows. Eur Respir J 1993;16: Suppl. 6 5s–40s.
  13. Hankinson JL, Odencrantz JR, Fedan KB. Spirometric reference values from a sample of the general U.S population. Am J Respir Crit Care Med 1999;159:179–187.[Abstract/Free Full Text]
  14. Garcia-Rio F, Pino JM, Dorgham A, Alonso A, Villamor J. Spirometric reference equations for European females and males aged 65–85 yrs. Eur Respir J 2004;24:397–405.[Abstract/Free Full Text]
  15. Roca J, Burgos F, Sunyer J, et al. Reference values for forced spirometry. Eur Respir J 1998;11:1354–1362.[Abstract]
  16. U.S. Public Health Service National Heart, Lung and Blood Institute. Global Initiative for Chronic Obstructive Lung Disease: Global Strategy for the Diagnosis, Management, and Prevention of Chronic Obstructive Pulmonary Disease, 2004. www.goldcopd.com. Last updated: July 2005; last accessed: May 2005<1?tic n?>
  17. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159–174.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  18. Hardie JA, Buist AS, Vollmer WM, Ellingsen I, Bakke PS, Morkve O. Risk of over-diagnosis of COPD in asymptomatic elderly never-smokers. Eur Respir J 2002;20:1117–1122.[Abstract/Free Full Text]
  19. Pennock BE, Rogers RM, McCaffree DR. Changes in measured spirometric indices: what is significant? Chest 1981;80:97–99.[Free Full Text]



This article has been cited by other articles:


Home page
ChestHome page
J.-y. Jing, T.-c. Huang, W. Cui, F. Xu, and H.-h. Shen
Should FEV1/FEV6 Replace FEV1/FVC Ratio To Detect Airway Obstruction?: A Metaanalysis
Chest, April 1, 2009; 135(4): 991 - 998.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Capderou, M. Berkani, M.-H. Becquemin, and M. Zelter
A Method to Derive Lower Limit of Normal for the FEV1/Forced Expiratory Volume at 6 s of Exhalation Ratio From FEV1/FVC Data
Chest, February 1, 2009; 135(2): 408 - 418.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M. Cazzola, W. MacNee, F. J. Martinez, K. F. Rabe, L. G. Franciosi, P. J. Barnes, V. Brusasco, P. S. Burge, P. M. A. Calverley, B. R. Celli, et al.
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Eur. Respir. J., February 1, 2008; 31(2): 416 - 469.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J. Vandevoorde, S. Verbanck, D. Schuermans, L. Broekaert, D. Devroey, J. Kartounian, and W. Vincken
Forced vital capacity and forced expiratory volume in six seconds as predictors of reduced total lung capacity
Eur. Respir. J., February 1, 2008; 31(2): 391 - 395.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
V Bellia, C Sorino, F Catalano, G Augugliaro, N Scichilone, R Pistelli, C Pedone, and R Antonelli-Incalzi
Validation of FEV6 in the elderly: correlates of performance and repeatability
Thorax, January 1, 2008; 63(1): 60 - 66.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
K. Kiviranta and T. Haahtela
Caucasian race and lung function: time to revisit the racial groups used in reference values
Eur. Respir. J., December 1, 2006; 28(6): 1280 - 1280.
[Full Text] [PDF]


Home page
Eur Respir JHome page
J. Vandevoorde and M. Swanney
Is forced expiratory volume in six seconds a valid alternative to forced vital capacity?
Eur. Respir. J., December 1, 2006; 28(6): 1288 - 1289.
[Full Text] [PDF]


Home page
ChestHome page
R. L. Jensen, R. O. Crapo, P. Enright, and Others From the Family Heart Study
A Statistical Rationale for the Use of Forced Expired Volume in 6 s
Chest, December 1, 2006; 130(6): 1650 - 1656.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
G Laszlo
Standardisation of lung function testing: helpful guidance from the ATS/ERS Task Force
Thorax, September 1, 2006; 61(9): 744 - 746.
[Full Text] [PDF]


Home page
Eur Respir JHome page
J. E. Hansen, X-G. Sun, and K. Wasserman
Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction?
Eur. Respir. J., June 1, 2006; 27(6): 1244 - 1250.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
O. F. Pedersen
FEV6: a shortcut in spirometry?
Eur. Respir. J., February 1, 2006; 27(2): 245 - 247.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vandevoorde, J.
Right arrow Articles by Vincken, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vandevoorde, J.
Right arrow Articles by Vincken, W.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS