ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Knox, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Knox, J.
Eur Respir J 2003; 21:556-560
Copyright ©ERS Journals Ltd 2003


The European Community Respiratory Health Survey II

J. Knox, D. Jarvis and on behalf of the ECRHS II Steering Committee

Dept of Public Health Sciences, King's College London, London, UK

To the Editor:

The European Community Respiratory Health Survey (ECRHS) II is a multicentre study that includes assessment of bronchial responsiveness using the MefarTM dosimeter (MefarTM, Brescia, Italy). Ward et al. 1 report that in some centres taking part in ECRHS II, there is potential for systematic variation in MefarTM dosimeter driving pressure, which constitutes possible significant confounding for between-centre comparisons of bronchial hyperresponsiveness. They reported a wide range of driving pressures between centres "ranging between 70–245 kPa, with most outside the quoted manufacturer's specification of 180±5%".

Ward et al. 2 drew our attention to this problem when we were developing the quality control programme for ECRHS II. All ECRHS II centres were requested to check dosimeter driving pressure at least once a month and to send reports to the Coordinating Centre. Where readings were <160 kPa or >180 kPa, centres were advised to adjust the dosimeter to a level within these limits. R.J. Ward and his group set up a website with instructions on how this could be achieved, together with information on the testing procedure.

Reports were received from all centres except for Umea (Sweden) and showed that no centre recorded a level<160 kPa and the highest value was 200 kPa, found in Hamburg (Germany). In Hamburg, alterations were made to the equipment and it operated at ~180 kPa for the rest of the study. The mean pressure for centres throughout the study ranged 160 kPa–189 kPa (Hamburg had a higher mean due to its driving pressure being 200 kPa for a period).

Although table 1 of the paper concerned 1 implies a substantial problem within the participating European Community Respiratory Health Survey II centres, the quality control programme reveals that although variation exists, the magnitude and its influence on between-centre comparisons is much smaller than suggested by Ward et al. 1 in their recent paper.

References

  1. Ward RJ, Ward C, Johns DP, Skoric B, Abramson M, Walters EH. European Community Respiratory Health Survey calibration project of dosimeter driving pressures. Eur Respir J 2002;19:252–256.[Abstract/Free Full Text]
  2. Ward RJ, Liakakos P, Leonard RF, Reid DW, Johns DP, Walters EH. A critical evaluation of the MefarTM dosimeter. Eur Respir J 1999;14:430–434.[Abstract]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Knox, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Knox, J.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS