|
|
||||||||
1 Dept Physiology and Pharmacology, Karolinska Institute and 2 Dept Oto-Rhino-Laryngology, Huddinge University Hospital, Stockholm, Sweden
CORRESPONDENCE: J.O.N. Lundberg, Dept Physiology and Pharmacology, Karolinska Institutet 171 77, Stockholm, Sweden. Fax: 46 8332278. E-mail: jon.lundberg@fyfa.ki.se
Keywords: asthma, breath test, exhaled air, rhinitis, sinuses, sinusitis
Received: November 8, 2001
Accepted February 13, 2002
This study was supported by grants from The Swedish Research Council, The Heart & Lung Foundation, The Karolinska Institutet and Ruth & Richard Juhlins Foundation.
| Abstract |
|---|
|
|
|---|
Nasal NO was detected in all subjects and the concentrations were highly flow-dependent (mean±sem: 236±23 and 527±49 parts per billion (ppb), at 2 and 0.5 L·min1, respectively). In contrast, no evidence of CO release in the nasal airways regardless of sample flow rate was found. In fact, additional experiments indicated a net absorption of CO when low levels of this gas were flushed through the nasal cavity. Nasal CO also remained undetectable after smoking. Both NO (22±2 ppb) and CO (1.1±0.1 parts per million) were consistently found in orally exhaled air. CO, but not NO, levels increased acutely after smoking a cigarette.
The authors conclude that the patterns of nitric oxide and carbon monoxide release in the airways seem to differ profoundly in healthy subjects. Orally exhaled air contains both nitric oxide and carbon dioxide whereas nasal air contains nitric oxide only.
Measurements of airway-derived nitric oxide (NO) have received a lot of attention over the past decade 13. Exhaled NO is increased in asthma 2 and suggestions have been made that this noninvasive test can be used to monitor airways inflammation. In healthy subjects NO release in the lower airways is generally low 4. In contrast, high levels of NO are found in the nasal airways of healthy subjects 4. Parts of the NO found in nasally derived air is produced in the paranasal sinuses, where a high-rate producing inducible NO synthase is constantly expressed 5.
The finding that NO is released at different levels in the respiratory system in health and disease has triggered an interest in also measuring other gaseous compounds in exhaled breath. Recently, there have been several reports on increased levels of exhaled carbon monoxide (CO) in patients with airways inflammation 617. In addition, it has also been suggested that CO is released in the nose and paranasal sinuses of healthy people 18. Thus, it seems as though NO and CO coexist in the airways both in health and disease. Despite the relatively large numbers of studies looking at the airway release of NO or CO there have been few attempts to measure both gases simultaneously in healthy subjects using standardised procedures. The current authors therefore, decided to study the levels of both NO and CO in healthy subjects at different levels of the respiratory tract.
| Materials and methods |
|---|
|
|
|---|
Collection of nasal air
A tightly fitting nasal olive was introduced into one nostril. The olive was connected to a suction pump and flow was adjusted to 0.5, 1 or 2 L·min1. Aspirated air was led into a nonreactive polyurethane bag (0.6 L) impermeable to NO and CO. During sampling the subjects were asked to hold their breath with the mouth closed forcing air to flow from one nostril to the other via the nasopharynx. Sampling was initiated immediately following nasal inspiration to total lung capacity (TLC). To assure zero inlet levels of CO and NO a second olive was introduced into the other nostril and further connected to a clean-air reservoir. NO- and CO-free air was generated by feeding medical breathing air (AGA AB, Stockholm, Sweden) through a Purafill drypowder scrubber and an electronic scrubber (Alphagaz air flow, Air Liquide Gas AB, Kista Sweden).
In five of the subjects CO was also measured in air (1.4 parts per million (ppm) CO) that had passed through the nose from one nostril to the other. The aspirating (0.5 L·min1) sampling tube of the CO analyser (see below) was connected to an olive and introduced into one nostril. A second olive was connected to the bag with CO-containing air and introduced in the other nostril. During sampling the subjects were asked to hold their breath. When measuring nasal NO and CO after smoking a cigarette the flow of 2 L·min1 was used.
Collection of orally exhaled air
The subjects inhaled to TLC from a clean-air reservoir and exhaled after a breath-hold of 5 s. The first portion of exhaled air was discarded, whereas the last portion was collected at a flow rate of 4050 mL·s1 in a polyurethane bag for immediate analysis of NO, CO and CO2.
Analysis of nitric oxide carbon monoxide and carbon dioxide
Analysis of the gases in the polyurethane bags was carried out within 1 min of airway sampling starting with CO2 followed by NO and CO. CO2 was measured with an infrared (IR) technique (Capnomac, Datex, Sweden), as was CO (NDIR analyser, UNOR 610; Maihak AG, Hamburg, Germany) and NO with chemiluminescence (AM 77 Eco Physics, Switzerland). Sample air was dehumidified with Naphion membranes before NO and CO analyses. The detection limits for CO2, CO and NO were 0.2%, 0.1 ppm and 1 parts per billion (ppb)/ respectively. In all cases the amount of air in the bag was sufficient to give a full recovery of the signal by the three different analysers. The stability of the gases in the polyurethane bags was tested in some cases by measuring NO, CO and CO2 once again 3 min later which gave the same result (data not shown). A two-point calibration was performed for all three analysers using medical breathing air (zero point calibration) and synthetic gas mixtures in nitrogen (10 ppm NO, 20 ppm CO and 5% CO2, AGA AB, Lidingö, Sweden).
During the experiments ambient levels of NO and CO never exceeded 10 ppb and 0.1 ppm, respectively.
| Results |
|---|
|
|
|---|
|
|
Orally exhaled air
NO was found at a level of 22±2 ppb in orally exhaled air. CO was detected in all subjects with a mean value of 1.1±0.1 ppm (range 0.32.1 ppm). The CO2 signal was 4.8±0.1%. Smoking a cigarette caused a three-fold rise in CO (from 1.2±0.2 to 3.7±0.5 ppm) whilst NO remained unchanged (20±3 before smoking versus 21±2 ppb after smoking).
| Discussion |
|---|
|
|
|---|
CO was present in orally exhaled air. The levels of CO in orally exhaled air exceeded NO by a factor of 30, and increased as predicted after smoking a cigarette. In contrast, no evidence of CO release in the nasal airways was found. If CO was continuously produced, and released in significant amounts in the nasal airways one would expect a flow-dependency in the obtained values as observed for NO. However, the authors were unable to detect any CO signal in nasal air even at the lowest flow-rates used. The high levels of NO in the very same sample bag confirmed the true nasal origin of this air. Moreover, the absence of CO2 in the nasal samples did exclude the possibility of contamination with lower airway gases.
The IR technique used for CO measurements is considered very accurate for measuring CO even in the sub-ppm range. Indeed, the capability of the analyser to detect low levels of CO in this set-up was verified by the oral measurements, where a clear CO signal was uniformly seen in all subjects (0.32.1 ppm). In fact, even a 10-fold dilution of orally exhaled air (CO=2.0 ppm) with zero air gave a clear signal of 0.2 ppm, which is close to the detection limit of the analyser (data not shown). Obviously, the fact that CO may be released in the nose at levels lower than this cannot be excluded. Andersson et al. 18 reported nasal and sinus levels of CO >1 ppm, which is in sharp contradiction to the present findings. The reason for the discrepancy between the two studies can only be speculated upon. Nevertheless, there are some methodological differences between the two studies. In the study by Andersson et al. 18 ambient CO levels were much higher (0.75 ppm) and these were subtracted from the obtained values. The present study used CO-free air, which was introduced in the contralateral nostril during sampling. Moreover, ambient CO levels were very low throughout the experimental period. It could be speculated that in areas of high ambient CO levels, this gas is absorbed into the blood or mucus and slowly released in the nose during a long period of time after exposure. This has been well characterised for orally exhaled CO where the levels are increased a long period of time after smoking a CO-containing cigarette, and this is due to the rather slow uncoupling of CO from haemoglobin. However, in this study no increase in nasal CO after smoking was found, indicating that any passage of CO from the blood to the nasal cavity is low. Andersson et al. 18 sampled nasal air during tidal breathing through the mouth as one part of the study. This approach would increase the risk for contamination with lower airway CO to nasal air. However, this still does not explain the high CO signal found in nasal air in two subjects breathing through a tracheostoma thereby excluding contamination from the lower airways.
When flushing the nasal cavity with CO-containing synthetic air (1.4 ppm CO) it was observed that CO levels dropped by 0.30.8 ppm during passage from one nostril to the other. This indicated a net absorption of CO by the nasal mucosa. Thus, rather than being continuously released in the nose from cellular sources it seems as if this gas, in part, is taken up by the mucosa. An alternative explanation is that the CO signal is quenched by some factor in the nose, e.g. water vapour. However, this is less likely since mixing of synthetic CO at a known concentration with either nasally derived air or synthetic dry air gave the same CO signal (unpublished observation). Furthermore, according to the manufacturer the maximum quenching by water vapour or CO2 is <2%.
As mentioned above nasal NO is strongly flow-dependent and earlier studies have shown that this is also true for orally exhaled NO 3. The flow-dependency of both NO and CO in orally exhaled air was studied recently by Zetterquist et al. 20. It was shown that orally exhaled CO is not flow-dependent, whereas NO is. This strongly indicates that NO originates predominantly in the airways whereas CO is of alveolar origin.
To conclude, the airway release of nitric oxide and carbon monoxide seem to differ profoundly with regards to the amount and location in healthy subjects. Nasal air contains high levels of nitric oxide but no carbon monoxide, whereas air from the lower airways and lungs contains both nitric oxide and carbon monoxide.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
P. E. Silkoff Monitoring nitric oxide: here to stay for bench and bedside Eur. Respir. J., June 1, 2005; 25(6): 949 - 950. [Full Text] [PDF] |
||||
![]() |
S. W. Terheggen-Lagro, M. W. Bink, H. J. Vreman, and C. K. van der Ent End-Tidal Carbon Monoxide Corrected for Lung Volume Is Elevated in Patients with Cystic Fibrosis Am. J. Respir. Crit. Care Med., November 15, 2003; 168(10): 1227 - 1231. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Zetterquist, J.O.N. Lundberg, and K. Alving From the Authors Eur. Respir. J., January 1, 2003; 21(1): 197 - 198. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |