1 Dept of Respiratory Medicine, Occupational Lung Diseases Unit, Heartlands Hospital, Birmingham, UK. 4 Institut National de Recherche et de Securite, Vandoeuvre les Nancy Cedex, France. 3 Institute of Occupational Health, University of Birmingham, Birmingham, UK
CORRESPONDENCE: K.M. Thickett, Occupational Lung Diseases Unit, Dept of Respiratory Medicine, Heartlands Hospital, Bordesley Green East, Birmingham, B5 5SS, UK. Fax: 44 1217720292. E-mail: kt01265702@blueyonder.co.uk
Keywords: bronchial provocation test, nitrogen trichloride, occupational asthma, peak expiratory flow, swimming pool
Received: March 3, 2001
Accepted October 21, 2001
| Abstract |
|---|
|
|
|---|
Two lifeguards and one swimming teacher with symptoms suggestive of occupational asthma kept 2-hourly measurements of peak expiratory flow at home and at work, analysed using the occupational asthma system (OASYS) plotter, and/or had specific bronchial challenge testing to nitrogen trichloride, or a workplace challenge.
Air measurement in one of the pools showed the nitrogen trichloride levels to be 0.10.57 mg·m3, which was similar to other studies. Two workers had peak expiratory flow measurements showing occupational asthma (OASYS-2 scores 2.88 and 3.8), both had a positive specific challenge to nitrogen trichloride at 0.5 mg·m3 with negative challenges to chlorine released from sodium hypochlorite. The third worker had a positive workplace challenge.
Swimming-pool asthma due to airborne nitrogen trichloride can occur in workers who do not enter the water because of this chloramine. The air above indoor swimming pools therefore needs to be assessed and managed as carefully as the water.
Chlorine releasing agents (calcium or sodium hypochlorite and chlorinated isocyanuric acids) are frequently used for the disinfection of water in swimming pools. The free chlorine reacts with pollutants introduced by humans, such as sweat and urine 1, to form aldehydes, halogenated hydrocarbons, and chloramines. Some of these compounds are transferred to the atmosphere above swimming pools, either as gases or droplets. Lahl et al. 2 described chemical reactions leading to the formation of chloramines, but emphasized that chloroform was the most common compound formed. Chloramines include the inorganic compounds chloramide (monochloramine (NH2Cl)), chlorimide (dichloramine (NHCl2)), and nitrogen trichloride (trichloramine (NCl3)). The reaction that leads to the formation of inorganic chlorides 3 is:
|
| (001) |
|
| (002) |
|
| (003) |
The aims of this study were: 1) to investigate whether nitrogen chloride can cause asthma amongst swimming-pool instructors and lifeguards; and 2) to measure typical nitrogen trichloride exposure levels in indoor swimming pools and generate these levels under laboratory conditions for provocation tests.
| Methods |
|---|
|
|
|---|
Nonspecific reactivity to histamine or methacholine was measured using the technique devised by Yan et al. [8] (normal >8 µmol). Specific provocation tests were also performed, which involved the generation and measurement of nitrogen chloride under laboratory conditions 9.
Generation of nitrogen chloride for provocation tests
Gaseous nitrogen trichloride was formed by the combination of ammonium sulphate and sodium hypochlorite. The pH, concentration and ratio are extremely important, as it is a potentially explosive mixture. The experiment was designed to produce nitrogen trichloride at a concentration of 0.5 mg·m3 in a challenge chamber, this concentration being at the upper end of the range measured in swimming pools 1, 6. Ten millilitres of ammonium sulphate solution (0.432 g ammonium sulphate dissolved in 1,000 mL of water) was buffered to pH 3 with citric acid and disodium hydrogen phosphate and added to the first Drecshel bottle. Immediately before the exposure an excess of sodium hypochlorite (10 mL of a solution made from 5 mL of sodium hypochlorite in 100 mL of water) was added to the ammonium sulphate solution. The nitrogen trichloride was aspirated through two further Drecshel bottles. The first intermediate bottle contained 1% sulphamic acid to remove any chlorine vapours and the second bottle contained distilled water to trap any mono- or dichloramines. Fresh solutions were made up before each 10-min exposure. Air measurements of nitrogen trichloride were made during the challenge tests.
Provocation tests
On the first test day, three 10-min exposures to chlorine were performed, generated by painting a 1:20 dilution of sodium hypochlorite in water onto cardboard, sufficient to generate an estimated chlorine concentration of 0.5 mg·m3 (chlorine air measurements were not made during these challenges). On day 2, two 10-min exposures to nitrogen trichloride were performed. Spirometry was recorded at 5-min intervals for the first 30 min after each set of exposures, at 10-min intervals for the next 30 min, and then hourly until 12 h from the start of the test.
The lifeguard in case three had a workplace challenge test in which spirometry was measured at the poolside, using a Vitalograph spirometer (Vitalograph Ltd, Maids Moreton, Buckingham, UK). After establishing a baseline forced expiratory volume in one second (FEV1), the lifeguard was taken to the poolside for three 10-min exposures. FEV1 measurement consistent with standard European guidelines of acceptability and reproducibility 10 was performed after each exposure then every 5 min after the third exposure.
Measurement of airborne levels of nitrogen trichloride
The atmospheric nitrogen trichloride levels were measured at the poolside in case one and during the specific challenge tests. The sampling and analysis of nitrogen chloride was conducted using the method proposed by Hery et al. 1. In brief the sampling device comprised of two parts: a tube containing silica gel coated with sulphamic acid to trap hypochlorite and mono- and dichloramine, and a cassette containing a quartz filter treated with sodium carbonate and diarsenic trioxide to trap nitrogen chloride. Sampling was conducted by drawing air through the sampling device using a calibrated pump operating at 1.1 L·min1. After sampling, the quartz filter was desorbed in distilled water and the resulting solution analysed by ion chromatography using a cation exchange resin and a phthalic acid mobile phase adjusted to pH 4.2. The sampling and recovery efficiency of the filters used has been reported to be >95% 1.
A total of 15 samples for nitrogen chloride were collected in three indoor swimming pools over a 2-day period. Samplers were placed at positions normally occupied by the pool attendants, at
1 m from the floor level. The airborne nitrogen chloride concentrations were also measured during the challenge test with the sampler located close to the breathing zone. All sampling pumps were calibrated before and after collection of each sample.
| Results |
|---|
|
|
|---|
|
Case two
A 33-yr-old female who had worked as a lifeguard in a leisure centre for the previous 15 yrs presented with a 1-yr history of wheeze, chest tightness, dry throat and sore eyes, which would begin within 1 h of starting work and persist for 1 h afterwards. After 6 months the subject started waking at night with wheeze and breathlessness, which only improved during periods away from work. Ventilation at the pool was felt to be poor. Medication included 400 µg budesonide twice daily and 500 µg terbutaline as required. There was no history of eczema or hay fever, although the subject had had asthma in childhood which had not required any treatment after the age of 11 yrs. Skin tests to common environmental allergens showed strong positive reactions to house dust mite and moderate reactions to cat dander and the moulds Cladosporium and Alternaria. White cell and eosinophil counts were normal. The FEV1 was 3.41 (predicted 3.41) and FVC 4.01 (predicted 3.81). There was no significant reversibility in FEV1 (3.51) to nebulized salbutamol. The subject was relocated away from the poolside but within the swimming-pool complex with no change in symptoms. Subsequently, the subject moved to work in a library and had no symptoms apart from occasional morning chest tightness. A terbutaline inhaler was available to use as required and the steroid inhaler was stopped altogether.
Case three
A 49-yr-old male worked as a swimming-pool lifeguard for 12 yrs without any respiratory problems. Following a respiratory tract infection the subject developed cough, wheeze and breathlessness, which were aggravated by exercise, car fumes, passive cigarette smoking and chest infections. Treatment included 600 µg budesonide twice daily and 200 µg salbutamol as required. The subject had previously smoked heavily (60 pack-yrs). Symptoms remained the same for 2 yrs. However, following recovery from a further respiratory tract infection within 10 min of being at the poolside the subject became breathless, extremely wheezy and had sore eyes. The subject had to leave the poolside immediately, and on one occasion the subject had to go straight to a general practitioner for nebulized therapy. The symptoms persisted for 12 h after leaving the pool. There was no history of eczema or hay fever and there was no family history of asthma. Skin tests to common environmental allergens were negative. White cell and eosinophil counts were normal. Spirometry revealed an FEV1 of 2.91 (predicted 3.41) and an FVC of 4.31 (predicted 4.31). Following nebulized salbutamol FEV1 fell to 2.71. The carbon monoxide transfer coefficient (KCO) was 1.63 (predicted 1.89) mmol·min1KPa1. On retirement, the symptoms improved and the subject was only breathless when walking on an incline. The subject was maintained on the same medication but rarely required inhaled salbutamol.
Table 2
shows the results of the PEF plots and challenge tests. No worker had increased nonspecific reactivity before the tests, although one was hyperresponsive before removal from work exposure. Two subjects completed satisfactory PEF measurements, which showed significant work-related changes with OASYS-2 analysis. One worker was unable to complete PEF measurements because of wheeziness within 30 min of arriving at the poolside and required a nebulizer (case three), making further exposures impossible. The swimming teacher's plot is shown in figure la
and the plot of case two in figure lb
. Analysis after linearization and day interpretation using OASYS-2 showed scores of 3.8 and 2.88, respectively, within the definite occupational effect range. The challenges of cases one to three (figs. 2ac
) are shown with an unexposed control (fig. 2d
), where a hyperresponsive patient with occupational asthma, reproduced by painting 0.1% formaldehyde, had a positive challenge to formaldehyde, and some response to nitrogen trichloride. All three swimming-pool workers had immediate asthmatic reactions to nitrogen trichloride (or swimming-pool air) and one had an additional late asthmatic reaction. None reacted to the chlorine exposure. The levels of nitrogen trichloride measured in the indoor swimming pool (case one) ranged from 0.230.57 mg·m3 in the smaller teaching pool where the subject worked, and from 0.10.31 mg·m3 in the main pool. Levels during the challenge tests were 0.5 mg·m3.
|
|
|
| Discussion |
|---|
|
|
|---|
The mechanism of the occupational asthma due to nitrogen trichloride in the present cases was not, as is so often the case, completely clear. Some require measurement of nonspecific responsiveness outside the normal range before diagnosing asthma. In the authors' experience, specific reactivity to occupational sensitizers is commonly seen in workers with normal nonspecific reactivity 11. Reactivity can return to normal after cessation of exposure. Case two was hyperresponsive at presentation, but had returned to normal before the specific challenge was performed 1 yr after the last exposure, in keeping with removal from a sensitizing agent. The normal nonspecific reactivity before the challenge and the latent interval between first exposure and first symptom in the other two cases point to some form of specificity or hypersensitivity. Some would argue that the failure to induce nonspecific reactivity postchallenge is against a conventional immunoglobulin-E mediated reaction. One "nonexposed" worker (case four) was challenged with nitrogen trichloride using the same protocol. The worker had extreme sensitivity to formaldehyde and clinically reacted when working in a building some way from the nearest formaldehyde source. There was hyperresponsiveness to methacholine and a somewhat variable baseline. The worker's FEV1 probably did drop following nitrogen trichloride, which may represent a nonspecific, perhaps irritant, response, but its duration was longer than usually seen with an irritant. A further exposure to painted distilled water was carried out, which showed an insignificant fall in FEV1 (fig. 2d
).
It is possible that nitrogen trichloride is a much more general cause of asthma. In a questionnaire-based survey of 738 competitive swimmers, a high prevalence of respiratory symptoms was noted, including sneezing (45%), breathing difficulty (39.4%), coughing (36.4%), sore eyes (36%), wheezing (26.3%), chest tightness (34.8%) and chest congestion (22.8%) 12. Nearly 21% of swimmers who swam at international level reported asthma. Potts 12 compared bronchial responsiveness to methacholine in 35 competitive swimmers and 16 nonswimming athletes and found that >60% of competitive swimmers demonstrated increased bronchial responsiveness to methacholine (provocative concentration causing a 20% fall in the FEV1 <16 mg·mL1), while only 12.5% of nonswimmers had similar results. Among the competitive swimmers, the prevalence of bronchial responsiveness was similar in those swimmers who had asthma and/or exercise symptoms suggestive of asthma (61.1%) to those who had neither asthma nor symptoms (58.8%). The authors have also seen two other workers who developed occupational asthma following exposure to chloramines. One patient worked as an endoscopy nurse and used sterilox (which contains ionized sodium chloride) to sterilize endoscopes, and the other worked as a forensic scientist. The latter developed symptoms whilst working at a database adjacent to a deoxyribose nucleic acid extraction area where a disinfectant containing chlorine was used. The symptoms abated when the patient worked in a mitochondrial laboratory that did not use the disinfectant. Both of these workers found they developed chest tightness if they visited an indoor swimming pool.
To conclude, nitrogen trichloride is a cause of occupational asthma. This should be considered when choosing chlorine-based disinfectants that are likely to come into contact with a nitrogen source. It should also be considered in anyone developing occupational asthma working at a swimming pool and is also a likely cause of asthma in those who swim in these pools. To prevent further cases, much more attention should be paid to the quality of air in indoor swimming buildings, as well as to the care of the chlorine content of the water.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
R. V. Babu, V. Cardenas Jr, and G. Sharma Acute Respiratory Distress Syndrome From Chlorine Inhalation During a Swimming Pool Accident: A Case Report and Review of the Literature J Intensive Care Med, July 1, 2008; 23(4): 275 - 280. [Abstract] [PDF] |
||||
![]() |
J. H. Jacobs, S. Spaan, G. B. G. J. van Rooy, C. Meliefste, V. A. C. Zaat, J. M. Rooyackers, and D. Heederik Exposure to trichloramine and respiratory symptoms in indoor swimming pool workers Eur. Respir. J., April 1, 2007; 29(4): 690 - 698. [Abstract] [Full Text] [PDF] |
||||
![]() |
N Massin, G Hecht, D Ambroise, M Hery, J P Toamain, G Hubert, M Dorotte, and B Bianchi Respiratory symptoms and bronchial responsiveness among cleaning and disinfecting workers in the food industry Occup. Environ. Med., February 1, 2007; 64(2): 75 - 81. [Abstract] [Full Text] [PDF] |
||||
![]() |
M J Nieuwenhuijsen The chlorine hypothesis: fact or fiction? Occup. Environ. Med., January 1, 2007; 64(1): 6 - 7. [Full Text] [PDF] |
||||
![]() |
M Nickmilder and A Bernard Ecological association between childhood asthma and availability of indoor chlorinated swimming pools in Europe Occup. Environ. Med., January 1, 2007; 64(1): 37 - 46. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Bernard and M Nickmilder Respiratory health and baby swimming Arch. Dis. Child., July 1, 2006; 91(7): 620 - 621. [Full Text] [PDF] |
||||
![]() |
M. Medina-Ramon, J. P. Zock, M. Kogevinas, J. Sunyer, X. Basagana, J. Schwartz, P. S. Burge, V. Moore, and J. M. Anto Short-term respiratory effects of cleaning exposures in female domestic cleaners Eur. Respir. J., June 1, 2006; 27(6): 1196 - 1203. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Stav and M. Stav Asthma and whirlpool baths. N. Engl. J. Med., October 13, 2005; 353(15): 1635 - 1636. [Full Text] [PDF] |
||||
![]() |
M Medina-Ramon, J P Zock, M Kogevinas, J Sunyer, Y Torralba, A Borrell, F Burgos, and J M Anto Asthma, chronic bronchitis, and exposure to irritant agents in occupational domestic cleaning: a nested case-control study Occup. Environ. Med., September 1, 2005; 62(9): 598 - 606. [Abstract] [Full Text] [PDF] |
||||
![]() |
J W Dickinson, G P Whyte, A K McConnell, and M G Harries Impact of changes in the IOC-MC asthma criteria: a British perspective Thorax, August 1, 2005; 60(8): 629 - 632. [Abstract] [Full Text] [PDF] |
||||
![]() |
P S Burge Sick building syndrome Occup. Environ. Med., February 1, 2004; 61(2): 185 - 190. [Full Text] [PDF] |
||||
![]() |
O. Vandenplas and J-L. Malo Definitions and types of work-related asthma: a nosological approach Eur. Respir. J., April 1, 2003; 21(4): 706 - 712. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Varraso, N. Massin, M. Hery, M. Fradier-Dusch, J.-P. Michaely, M. Fournier, G.`v. Hubert, P. Biette, B. Rieger, A. Berthelin, et al. Not only training but also exposure to chlorinated compounds generates a response to oxidative stimuli in swimmers Toxicology and Industrial Health, July 1, 2002; 18(6): 269 - 278. [Abstract] [PDF] |
||||
![]() |
B. Nemery, P.H.M. Hoet, and D. Nowak Indoor swimming pools, water chlorination and respiratory health Eur. Respir. J., May 1, 2002; 19(5): 790 - 793. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |