ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (58)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Giraud, V.
Right arrow Articles by Roche, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Giraud, V.
Right arrow Articles by Roche, N.
Eur Respir J 2002; 19:246-251
Copyright ©ERS Journals Ltd 2002


Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability

V. Giraud1 and N. Roche2

1 Dept of Respiratory Medicine, University of Paris René Descartes, Ambroise Paré Hospital, Boulogne, 2 Dept of Respiratory and Intensive Care Medicine, University of Paris Pierre et Marie Curie, Hôtel Dieu Hospital, Paris, France

CORRESPONDENCE: V. Giraud, Université de Paris René Descartes, Service de Pneumologie, Hôpital A. Paré, 9 Avenue Charles de Gaulle, F-92104, Boulogne Cédex, France. Fax: 33 149095801

Keywords: asthma control, inhaled corticosteroids, metered-dose inhaler, misuse, poor coordination

Received: February 22, 2001
Accepted August 9, 2001

This work was supported in part by a grant from 3M Pharma, Cergy, France.


    Abstract
 TOP
 Abstract
 Patients and methods
 Results
 Discussion
 Acknowledgements
 References
 
This study assessed whether the improper use of pressurized metered-dose inhalers (pMDIs) is associated with decreased asthma control in asthmatics treated by inhaled corticosteroids (ICS).

General practitioners (GPs) included consecutive asthmatic outpatients treated by pMDI-administered ICS and on-demand, short-acting ß2-agonists. They measured an asthma instability score (AIS) based on daytime and nocturnal symptoms, exercise-induced dyspnoea, ß2-agonist usage, emergency-care visits and global perception of asthma control within the preceding month; the inhalation technique of the patient also was assessed.

GPs (n=915) included 4,078 adult asthmatics; 3,955 questionnaires were evaluable. pMDI was misused by 71% of patients, of which 47% was due to poor coordination. Asthma was less stable in pMDI misusers than in good users (AIS: 3.93 versus 2.86, p<0.001). Among misusers, asthma was less stable in poor coordinators (AIS: 4.38 versus 3.56 in good coordinators, p<0.001).

To conclude, misuse of pressurized metered-dose inhalers, which is mainly due to poor coordination, is frequent and associated with poorer asthma control in inhaled corticosteroid-treated asthmatics. This study highlights the importance of evaluating inhalation technique and providing appropriate education in all patients, especially before increasing inhaled corticosteroid dosage or adding other agents. The use of devices which alleviate coordination problems should be reinforced in pressurized metered-dose inhaler misusers.

Asthma-related morbidity and costs remain high despite significant advances in the understanding, management and treatment of the disease. This may be due to several factors including increased asthma incidence, changes in environmental triggers, nonadherence of physicians to guidelines, noncompliance of patients, or failure of effective medications to reach their target at sufficient concentration because of misuse of inhalation devices. Indeed, inhalation remains the main route of administration for asthma therapy, since it allows drugs to reach high bronchial concentrations with low systemic bioavailability 1. This is especially important for corticosteroids, which are the most effective maintenance therapy in asthma care 2.

Due to their high cost-effectiveness ratio 3, pressurized metered-dose inhalers (pMDIs) are the most commonly used inhalation devices. However, a number of surveys suggest that pMDIs are frequently misused: according to a review of 21 studies, the frequency of misuse ranges from 14–90%, with an estimated average of 50% 4, 5. Misuse decreases lung deposition from 20% to 7% 6; Lindgren et al. 7 showed that the increase in forced expiratory volume in one second (FEV1) after inhalation of a short-acting ß2-agonist decreased by 30% in patients making inhalation errors, as compared to good pMDI users. When the drug used is an inhaled corticosteroid (ICS), the consequences of inhaler misuse have not been assessed and are less easily recognizable, since the expected benefits are not immediate and the disease is highly variable.

The present study was designed to determine if pMDI misuse is associated with increased asthma instability (as a marker of decreased corticosteroids efficacy) in patients treated with ICS.


    Patients and methods
 TOP
 Abstract
 Patients and methods
 Results
 Discussion
 Acknowledgements
 References
 
Subjects
General practitioners (GPs, n=915) were asked to include all consecutive consenting adult asthmatics (aged >15 yrs) who visited them, and had been treated for at least 3 months by regular ICS (500–1500 µg·day–1) and on-demand short-acting ß2-agonists, both administered by pMDI without holding chamber. The diagnosis of asthma had to be based on the operational definition provided by international guidelines 2. Exclusion criteria were concomitant treatments within the previous 3 months with long-acting ß2-agonists, long-term oral corticosteroids, ß-blocking agents (eye-drops or by oral route) and theophylline.

Data collection
Patients answered a short questionnaire assessing their beliefs about their own inhalation technique, previous demonstration and assessment of inhalation technique, and perception of the suitability and efficacy of the inhalation device. Then, the physician completed a questionnaire on asthma instability within the previous month (table 1Go) and recorded the highest value of three peak expiratory flow rate (PEFR) measurements. Finally, patients were requested to take a puff of their usual short-acting ß2-agonist with their usual inhalation technique, which was observed and rated by the GP according to prespecified items (table 2Go). GPs had been previously taught by trained clinical research assistants on how to assess inhalation technique according to these items.


View this table:
[in this window]
[in a new window]
 
Table 1— Asthma instability score

 

View this table:
[in this window]
[in a new window]
 
Table 2— Causes of metered-dose inhaler misuse

 
Asthma instability
An asthma instability score (AIS) was used which was developed by a panel of 11 experts (see Acknowledgement). Six items were selected because they were: 1) widely recommended and used for this purpose and 2) easy to collect in general practice. These items were: 1) daytime respiratory symptoms (chest discomfort, dyspnoea, cough, and wheezing); 2) asthma-related nocturnal awakenings; 3) exercise-induced asthma; 4) ß2-agonist usage; 5) serious exacerbations (i.e. requiring emergency medical intervention) and 6) global assessment by the GP of the evolution during the previous month. Then the panel determined the scoring range for each item, with the aim of detecting a clinically-significant difference for each one-point change. As indicated in table 1Go, this scoring system allowed the calculation of the global AIS, which could range from zero (best) to nine (worst).

Patient's inhalation technique
Inhalation technique was rated according to seven omissions and five errors (table 2Go) 1, 79. Patients were classified as "misusers" if at least one error or omission was made. A subgroup of misusers was defined according to coordination between actuation and inhalation. Coordination was classified as "poor" if at least one of three potential errors was made (inspiration by nose, actuation at the end of inspiration, no inspiration) and/or if the device was not actuated at the beginning of inspiration.

Statistical analysis
Comparisons of quantitative variables (i.e. age, AIS and PEFR) between groups (i.e. between good users and poor users with and without poor coordination, and between educated and noneducated patients) were performed using a bilateral t-test for comparison of means. The sensitivity of the results to separate removal of each item of the AIS was studied and the relationship between each potential error or omission in inhalation technique and AIS was assessed. Categorical variables (i.e. sex, age range, and cause of medical visit) were compared between the groups studied, using table analysis by Pearson's Chi-squared test 10. Correlations between quantitative variables (i.e. between AIS and PEFR, and between AIS and age) were studied by linear regression analysis. Values of p<0.05 were considered statistically significant. Data are reported as mean±sem unless otherwise indicated.


    Results
 TOP
 Abstract
 Patients and methods
 Results
 Discussion
 Acknowledgements
 References
 
Of the 4,198 questionnaires completed, 120 (2.8%) were excluded from analysis because of patient's ineligibility (age <15 yrs in five patients, recent use of long-acting ß2-agonists in 115). In the remaining population (n=4,078), 2,179 were males (54%) and 1,869 were females (46%), with a mean age of 46.3±19.3 yrs. PEFR was available in 3,055 patients (75% of eligible subjects), with a mean value of 382±106.8 L·min–1 (range: 105–800), i.e. 72.8±19.0% of predicted. The cause leading the patient to seek medical advice was first visit in 102 cases (3%), routine scheduled visit in 2,932 cases (70%), asthma worsening in 789 cases (20%) and an acute exacerbation in 149 cases (4%). Short-acting ß2-agonists had been taken within 4 h prior to the visit by 38% of patients.

Pressurized metered-dose inhaler misuse
Of the 3,955 patients in whom all corresponding items were documented (97% of the eligible population), 2,791 (71%) were considered as poor users; among them 1,320 (33%) were poor coordinators (corresponding to 47% of poor users). Among misusers, 78% made >1 error or omission in inhalation technique. Only 15% of poor users and 23% of poor coordinators self-rated their technique of inhalation as "poor" or "very poor". Causes of poor inhalation technique are given in table 2Go. The frequency of pMDI misuse increased with age and was 61.0% between 15–30 yrs, 70.0% between 30–60 yrs, 77.2% between 60–75 yrs, and 85.9% in patients >75 yrs (p<0.00001). There was no difference in the frequency of misuse between males and females (69.4 versus 72.0%, respectively; p=ns), although the frequency of poor coordination was slightly higher in females (35.9 versus 30.4% in males, p=0.0002).

Effect of prior education on inhalation technique and asthma instability
Before the visit, 84% of patients had been shown how to use their inhaler and inhalation technique had been checked in 68%. Misuse was less frequent in subjects in whom these two steps of education had been performed (66.5% versus 86.4% in subjects who received no education; p<0.0001). There was no difference between educated and noneducated patients in terms of AIS (3.73±0.11 versus 3.61±0.05; p=0.41) but PEFR was slightly but significantly lower in noneducated patients (70.4±0.4 versus 72.9±1.0; p=0.02). Worsened asthma condition was a more frequent cause of medical visit (3.3 versus 6.2%; p=0.005) in noneducated patients.

Relationship between pressurized metered-dose inhaler misuse, cause of medical visit and asthma instability
PEFR correlated to AIS (r=0.33, p<0.00001) and was lower in misusers (71.6±0.4% of predicted) and poor coordinators (70.1±0.6%) than in good users (75.5±0.6%, p<0.0001 for each comparison). The cause of medical visit in good users and misusers without and with poor coordination is given in table 3Go. Medical visits for worsened asthma condition or emergency visits were more frequent in misusers with poor coordination, than in misusers without poor coordination or good users (p<0.00001).


View this table:
[in this window]
[in a new window]
 
Table 3— Cause of medical visit, ß2-agonist usage, recent evolution of asthma and emergency care visit during the previous month according to inhalation technique and coordination

 
AIS and evaluation of inhalation technique were both available in 3,709 patients (91% of the eligible population). The distribution of the AIS in good users and misusers with and without poor coordination is given in figure 1Go. The mean AIS was higher in misusers than in good users and, among misusers, the mean AIS was higher in poor coordinators (table 4Go). In misusers as compared to good users, and in misusers with poor coordination as compared to misusers without poor coordination, the greater instability of asthma was reflected, in particular, by more frequent ß2-agonist use, recent worsening of asthma and occurrence of serious exacerbations (table 3Go, p<0.01 for all comparisons).



View larger version (54K):
[in this window]
[in a new window]
 
Fig. 1.— Distribution of asthma instability score (AIS) according to inhalation technique and coordination. {square}: misusers, poor coordinators; : misusers, good coordinators; : good users. n=3709 (91% of the eligible population). Analysis of variance: p<0.0001.

 

View this table:
[in this window]
[in a new window]
 
Table 4— Mean asthma instability score according to inhalation technique and coordination

 
There were significant differences in AIS according to the presence or absence of each single error or omission in inhalation technique (p=0.03 for cap removal and p<0.00001 for all others). Linear regression analysis showed that the number of errors in inhalation technique, as described in figure 2Go, correlated to the AIS (r=0.3, p<0.0001). According to stepwise analysis, errors or omissions that independently correlated to the AIS, were upside-down metered-dose inhaler holding, forced expiration prior to inhalation, inappropriate timing of device actuation including actuation at the end of inspiration, too high inspiratory flow rate, incomplete inspiration, double actuation and lack of apnoea following inspiration.



View larger version (38K):
[in this window]
[in a new window]
 
Fig. 2.— Frequency distribution of the number of errors or omissions in inhalation technique (left axis: ) and relationship between this number and AIS (mean±SEM, right axis: ). Correlation between number of errors and AIS (linear regression analysis): r=0.3, p<0.0001.

 
Sensitivity of the results to changes in asthma instability score items
Separate removal of each individual item of the AIS did not affect the relationship between this score and inhaler misuse with or without poor coordination (t-tests, p<0.0001 for all comparisons). Similarly, it did not alter the correlation of this score with PEFR (p<0.0001 for all regression analyses). Each single item of the AIS was influenced by misuse and especially poor coordination (p<0.0001 for all comparisons).


    Discussion
 TOP
 Abstract
 Patients and methods
 Results
 Discussion
 Acknowledgements
 References
 
In adult asthmatic patients treated with ICS and visiting their GP, the proportion of pMDI misusers was high and increased with age. Misuse and more specifically poor coordination were strongly associated with asthma instability. This suggests that the decrease in lung deposition which is associated with pMDI misuse reduces the clinical efficacy of ICS and impairs asthma control.

Several points have to be considered when interpreting the results. Firstly, participating GPs were volunteers, so that their interest in asthma might have induced a better knowledge of inhalation devices and a better education of their patients. Similarly, patients had to give their consent before participation in the study, which may influence the frequency of pMDI misuse. However, these potential bias would have led to underestimation of the frequency of pMDI misuse. This frequency was high (71%) but very similar to what has been found in other studies 4, 1114. Indeed, this study is, to the best of the authors' knowledge, the largest to assess the frequency of pMDI misuse.

Secondly, potential confounding factors were not considered, such as baseline disease severity, poor compliance, insufficient asthma treatment including inadequate ICS dosage, diagnostic errors, comorbid heart or respiratory illnesses, poor control of environmental triggers such as allergen exposure. However, the large size of the studied sample and the magnitude and consistency of the difference in asthma instability between pMDI misusers and good users make it unlikely that these differences were due only to confounding factors; in addition, all AIS items were influenced by misuse and especially poor coordination, and the relationship between misuse, poor coordination and AIS was insensitive to separate removal of each single item of the AIS: this suggests that misuse and especially poor coordination are very important factors for asthma control.

Greater asthma instability in patients treated by ICS and showing poor use of their inhaler might be explained by a direct mechanism (the failure of medication to reach the bronchi at adequate concentration) as well as an indirect one (lower compliance due to decreased efficacy). Such a vicious circle is quite classical with treatments of chronic diseases requiring a strict compliance: breaking it down is of utmost importance in a potentially fatal and resource-consuming disease such as asthma. Compliance could not be reliably assessed in this study since it was cross-sectional; prospective trials will be required to study its relationship with misuse.

The strict criteria used to define good use of pMDIs may partly account for the high frequency of misuse, however, these criteria are based on data from scintigraphic deposition studies 6, 8, 9, and, as outlined earlier, a figure of 71% remains within the range found by other sources 4, 1114. In addition, only a low proportion of misusers (22%) had only one error or omission and each single error was associated with asthma instability, which increased with the number of errors. The high frequency of poor coordination (47%) among possible causes of misuse is also in accordance with the results of previous surveys 4, as is the increase in misuse with age 12, 15. The association between poor coordination and worse asthma control in misusers suggests that one of the first aims of research on inhalation devices should be to alleviate coordination problems.

The impact of improper pMDI usage on the lung deposition of inhaled agents has been clearly demonstrated in numerous well-designed studies. Altogether, these studies found a 50–66% reduction in lung deposition in pMDI misusers 6, 8, 16. The clinical consequences of this decrease in lung deposition have been easy to demonstrate with bronchodilators, since an immediate indicator of drug effect does exist and is easy to measure (i.e., the magnitude of bronchodilation, which decreases by 30% with pMDI misuse) 7.

The picture is more complicated when the treatment targets a long-term effect and when the disease is intrinsically variable. In the present study, asthma instability was proposed as a potential indicator of the hazards of faulty inhaler technique. Because asthma can be severe but controlled, or moderate but unstable (depending on the adequacy of administered treatments) 2, 17, assessing instability appeared more relevant than assessing severity. The authors developed the AIS since there was no generally accepted and validated measure for asthma instability at the time of the current study. Although this score allowed the demonstration, for the first time, of a relationship between corticosteroid pMDI misuse and poor asthma control, the significance of this result could be questioned, since the AIS had not been formally validated before its use in this study. However, this score was developed by an expert panel using items which were widely recommended and used for assessment of asthma control, and which were all influenced by misuse and poor coordination; three out of six of the AIS items were used to define asthma control in the study by Reddel et al. 18, and four are part of the six-item asthma control questionnaire (ACQ) which has recently been transversally and longitudinally validated by Juniper et al. 19 in 50 patients. AIS items that are not included in the ACQ are emergency-care visits and global assessment of evolution by the patient. Conversely, ACQ but not AIS includes wheezing and FEV1. Other main differences between the AIS and the ACQ are the duration of retrospective assessment (1 week for the ACQ and 1 month for the AIS) and the way of scoring each item (six-point scales for the ACQ, two or three-point scales for the AIS). Although not formally tested, the discriminant properties of the AIS are suggested by its correlation with PEFR, which was highly significant although of low magnitude, as could be expected in ICS-treated patients. If this score was to be used in longitudinal studies, its responsiveness to change should be determined.

Finally, a one-point mean difference in AIS was found between good and poor users, corresponding to 11% of the maximal total AIS (i.e. nine points). Interestingly, the difference in variation of the ACQ between stable and unstable patients found by Juniper et al. 19 was 0.72, corresponding to 12% of the maximal total ACQ (i.e. six points). This suggests that a one-point difference in the AIS is indeed of clinical significance.

Fewer misusers than good users had received education on inhalation technique, which suggests that education is effective at improving inhaler technique. However, there was no significant direct relationship between education and AIS, which is most likely due to the fact that education is not always successful (errors are corrected in only 50% of poor users, 50% of whom return to their "bad habits" within a few weeks), and that misuse is obviously not the only factor that influences asthma control.

Another striking finding was the lack of awareness in poor users of their difficulties with pMDI inhalation technique, only 15% rating their pMDI use as "poor" or "very poor". As emphasized by others 20, this highlights the need for progress in asthmatics' education and about the correct use of inhalers.

To conclude, it is clearly important to evaluate patient inhalation technique, and especially coordination errors, before increasing inhaled corticosteroids dosage or adding long-acting ß2-agonists in patients in whom asthma is poorly controlled. Use of devices that make inhalation technique easier, such as holding chambers, breath-actuated devices and dry-powder inhalers should be reinforced in pressurized metered-dose inhaler misusers. This strategy, which is already recommended by international guidelines on asthma, should be more extensively implemented to limit the cost and side-effects of unnecessary additional treatments. The beneficial effect of improvement in inhalation technique or change in inhalation device, on asthma control, now needs to be demonstrated in prospective trials.


    Acknowledgements
 TOP
 Abstract
 Patients and methods
 Results
 Discussion
 Acknowledgements
 References
 
The authors wish to thank P. Chanez, B. Crestani, R. Dubost, A. Magnan, M. Murris-Espin, C. Pannelier, M. Pérol, T. Perez, O. Sitbon, C. Thiriet, M. Tunon de Lara for their help in designing the asthma instability score or organizing data collection.


    References
 TOP
 Abstract
 Patients and methods
 Results
 Discussion
 Acknowledgements
 References
 

  1. Roche N, Chinet T, Huchon G. Ambulatory inhalation therapy in obstructive lung diseases. Respiration 1997;64:121–130.[Web of Science][Medline] [Order article via Infotrieve]
  2. National Institutes of Health, National Heart, Lung and Blood Institute. Global Initiative for Asthma; Global strategy for asthma management and prevention; NHLBI/WHO workshop report. National Institutes of Health, Bethesda, MD, USA, 1995. Publication No. 95–3659: 1–176.
  3. Levy ML. Metered dose inhalers: current and future uses. Br J Clin Pract 1997;89:16–21.
  4. Chinet T, Huchon G. Misuse of pressurized metered-dose aerosols in the treatment of bronchial diseases. Incidence and clinical consequences. Ann Med Interne 1994;145:119–124.[Medline] [Order article via Infotrieve]
  5. Hanania NA, Wittman R, Kesten S, Chapman KR. Medical personnel's knowledge of and ability to use inhaling devices. Metered-dose inhalers, spacing chambers, and breath-actuated dry powder inhalers. Chest 1994;105:111–116.[Abstract/Free Full Text]
  6. Newman SP, Weisz AW, Talaee N, Clarke SW. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique. Thorax 1991;46:712–716.[Abstract/Free Full Text]
  7. Lindgren S, Bake B, Larsson S. Clinical consequences of inadequate inhalation technique in asthma therapy. Eur J Respir Dis 1987;70:93–98.[Web of Science][Medline] [Order article via Infotrieve]
  8. Newman SP, Pavia D, Garland N, Clarke SW. Effects of various inhalation modes on the deposition of radioactive pressurized aerosols. Eur J Respir Dis 1982;119:Suppl. 63, 57–65.
  9. Newman SP, Pavia D, Clarke SW. How should a pressurized beta-adrenergic bronchodilator be inhaled? Eur J Respir Dis 1981;62:3–21.[Web of Science][Medline] [Order article via Infotrieve]
  10. Zar JH. Biostatistical analysis. Engleton Cliffs, Prentice Hall, Inc., 1983.
  11. Liard R, Zureik M, Aubier M, Korobaeff M, Henry C, Neukirch F. Misuse of pressurized metered dose inhalers by asthmatic patients treated in French private practice. Rev Epidemiol Sante Publique 1995;43:242–249.[Web of Science][Medline] [Order article via Infotrieve]
  12. Goodman DE, Israel E, Rosenberg M, Johnston R, Weiss ST, Drazen JM. The influence of age, diagnosis, and gender on proper use of metered-dose inhalers. Am J Respir Crit Care Med 1994;150:1256–1261.[Abstract]
  13. Thompson J, Irvine T, Grathwohl K, Roth B. Misuse of metered-dose inhalers in hospitalized patients. Chest 1994;105:715–717.[Abstract/Free Full Text]
  14. Crompton GK. The patient's difficulties with inhalers. Lung 1990;168:658–662.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  15. Armitage JM, Williams SJ. Inhaler technique in the elderly. Age Aging 1988;17:275–278.[Free Full Text]
  16. Newman SP, Millar AB, Lennard-Jones TR, Moren F, Clarke SW. Improvement of pressurised aerosol deposition with Nebuhaler spacer device. Thorax 1984;39:935–941.[Abstract/Free Full Text]
  17. Cockroft DW, Swystun VA. Asthma control versus asthma severity. J Allergy Clin Immunol 1996;98:1016–1018.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  18. Reddel H, Ware S, Marks G, Salome C, Jenkins C, Woolcock A. Differences between asthma exacerbations and poor asthma control. Lancet 1999;353:364–369.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  19. Juniper EF, O'Byrne PM, Guyatt GH, Ferrie PJ, King DR. Development and validation of a questionnaire to measure asthma control. Eur Respir J 1999;14:902–907.[Abstract/Free Full Text]
  20. McFadden ER. Improper patient technique with metered-dose inhalers: clinical consequences and solutions to misuse. J Allergy Clin Immunol 1995;96:278–283.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]



This article has been cited by other articles:


Home page
Eur Respir JHome page
E. Mehuys, L. Van Bortel, L. De Bolle, I. Van Tongelen, L. Annemans, J. P. Remon, and G. Brusselle
Effectiveness of pharmacist intervention for asthma control improvement
Eur. Respir. J., April 1, 2008; 31(4): 790 - 799.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. K. Crompton
Inhaler technique blind spot.
Eur. Respir. J., May 1, 2006; 27(5): 1070 - 1071.
[Full Text] [PDF]


Home page
ChestHome page
G. K. Crompton, P. J. Barnes, M. B. Dolovich, R. C. Ahrens, D. R. Hess, P. Anderson, R. Dhand, J. L. Rau, G. C. Smaldone, and G. Guyatt
Aerosol Delivery Devices
Chest, May 1, 2006; 129(5): 1388 - 1389.
[Full Text] [PDF]


Home page
ERRHome page
S. P. Newman
Inhaler treatment options in COPD
Eur. Respir. Rev., December 1, 2005; 14(96): 102 - 108.
[Abstract] [Full Text] [PDF]


Home page
ERRHome page
K. R. Chapman, T. H. Voshaar, and J. C. Virchow
Inhaler choice in primary practice
Eur. Respir. Rev., December 1, 2005; 14(96): 117 - 122.
[Abstract] [Full Text] [PDF]


Home page
CMAJHome page
A. Becker, C. Lemiere, D. Berube, L.-P. Boulet, F. M. Ducharme, M. FitzGerald, T. Kovesi, and on behalf of The Asthma Guidelines Working Group o
Summary of recommendations from the Canadian Asthma Consensus Guidelines, 2003
Can. Med. Assoc. J., September 13, 2005; 173(6_suppl): S3 - S11.
[Full Text] [PDF]


Home page
CMAJHome page
Inhalation devices
Can. Med. Assoc. J., September 13, 2005; 173(6_suppl): S39 - S45.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
Statement on Home Care for Patients with Respiratory Disorders
Am. J. Respir. Crit. Care Med., June 15, 2005; 171(12): 1443 - 1464.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (58)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Giraud, V.
Right arrow Articles by Roche, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Giraud, V.
Right arrow Articles by Roche, N.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS