ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brown, P.
Right arrow Articles by Crompton, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brown, P.
Right arrow Articles by Crompton, G.
Eur Respir J 1995; 8: 1940-1941
Copyright © ERS Journals Ltd 1995


Original Articles

Peak inspiratory flow through Turbuhaler in acute asthma

PH Brown, AC Ning, AP Greening, A McLean, and GK Crompton

Efficient use of dry powder inhalers, such as Turbuhaler, is dependent on the generation of adequate inspiratory flow. It is not clear whether patients with acute asthma are able to generate adequate flow. Peak inspiratory flow (PIF) was measured through an empty Turbuhaler, and without this device, in 99 adults presenting to hospital with acute exacerbations of asthma. Where possible, patients were studied prior to nebulized bronchodilator therapy. Mean (SD) forced expiratory volume in one second (FEV1) was 1.2 (0.7) L, forced vital capacity (FVC) 2.1(1.0) L and peak expiratory flow (PEF) 199 (92) L.min-1. PIF without Turbuhaler was 152 (77) L.min-1 and correlated with PEF (r = 0.69). PIF through Turbuhaler was 60 (20) L.min-1 and weakly correlated with PEF (r = 0.35), and with PIF without Turbuhaler (r = 0.43). Two patients failed to generate the minimum inspiratory flow (30 L.min) required for efficient use of Turbuhaler; both recorded 26 L.min-1. Acute asthma is associated with considerable inspiratory, as well as expiratory airflow limitation. The relationship between inspiratory and expiratory airflow is not strong enough to predict whether patients with severe acute asthma will have difficulty using dry powder inhalers efficiently. Despite this, 98% of patients in this study generated inspiratory flow through Turbuhaler which would allow a therapeutically active amount of bronchodilator drug to be delivered to the airways.


This article has been cited by other articles:


Home page
Arch. Dis. Child.Home page
S Drblik, G Lapierre, R Thivierge, J Turgeon, P Gaudreault, B Cummins-McManus, I Verdy, J Haddon, J Lee, and S Spier
Comparative efficacy of terbutaline sulphate delivered by Turbuhaler dry powder inhaler or pressurised metered dose inhaler with Nebuhaler spacer in children during an acute asthmatic episode
Arch. Dis. Child., April 1, 2003; 88(4): 319 - 323.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
F Child, S Davies, S Clayton, A A Fryer, and W Lenney
Inhaler devices for asthma: do we follow the guidelines?
Arch. Dis. Child., March 1, 2002; 86(3): 176 - 179.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the European Respiratory Society.