ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mancebo, J
Right arrow Articles by Brochard, L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mancebo, J
Right arrow Articles by Brochard, L
Eur Respir J 1995; 8: 1901-1909
Copyright © ERS Journals Ltd 1995


Original Articles

Comparative effects of pressure support ventilation and intermittent positive pressure breathing (IPPB) in non-intubated healthy subjects

J Mancebo, D Isabey, H Lorino, F Lofaso, F Lemaire, and L Brochard

We compared the efficacy of three devices delivering assisted non-invasive ventilation with different working mechanisms, during room air breathing and during CO2-induced hyperventilation. In seven healthy volunteers, breathing pattern, respiratory muscle activity and comfort were assessed: during unassisted spontaneous breathing through a mouth-piece (SB); during assisted breathing with a device delivering inspiratory pressure support (IPS); and with two devices delivering intermittent positive pressure breathing (IPPB), the Monaghan 505 (IPPB1), and the CPU 1 ventilator (IPPB2). All three devices were set at 10 cmH2O of maximal pressure. During room air breathing, the work of breathing expressed as power, was significantly greater with the two IPPB devices than with the two other modes (IPPB1 and IPPB2 7.3 +/- 5.2 and 7.2 +/- 6.2 J.min-1, respectively, versus SB and IPS 2.4 +/- 0.7 and 2.3 +/- 3.3 J.min-1, respectively). The difference did not reach the statistical significance for the pressure-time product (PTP). Discomfort was also greater during the IPPB modes. During CO2-induced hyperventilation, considerable differences in power of breathing were found between the two IPPB devices and the other two modes. The PTP was also much higher with IPPB. Transdiaphragmatic pressure was significantly smaller during IPS than during the three other modes (IPS 18 +/- 2.6 cmH2O versus SB 22 +/- 2.6, IPPB1 32 +/- 5.2, and IPPB2: 28 +/- 5.2). Maximal discomfort was observed during the IPPB modes and was correlated with the magnitude of transdiaphragmatic pressure (r = 0.60). Despite similarities in their operational principles, IPS and IPPB had very different effects on respiratory muscle activity in healthy non-intubated subjects. IPPB machines not only failed to reduce patient's effort but also induced a significant level of extra work by comparison to spontaneous ventilation at ambient pressure. Great caution is, therefore, needed in the use of patient-triggered devices for non-intubated patients with acute respiratory failure.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
ChestHome page
A. Anton, R. Guell, J. Gomez, J. Serrano, A. Castellano, J. L. Carrasco, and J. Sanchis
Predicting the Result of Noninvasive Ventilation in Severe Acute Exacerbations of Patients With Chronic Airflow Limitation
Chest, March 1, 2000; 117(3): 828 - 833.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the European Respiratory Society.