Original Articles |
Interpretation of the protected specimen brush (PSB) technique is based on quantitative bacterial cultures (QC), which unfortunately requires at least 24 h. We prospectively compared the diagnostic value of direct examination (DE) and QC of PSB specimens in 75 patients with suspected pneumonia. We also determined the optimal technique for DE. QC was performed using the serial dilution technique. From the original suspension, two cytospin slides were obtained and stained by the May-Grunwald Giemsa (MGG) and the Gram method for DE. If the prescreening on the MGG-stained slide was positive, the morphology and the Gram staining of the organisms were assessed on the Gram-stained slide. Using the 10(3) colony forming units (cfu.ml-1) threshold for defining PSB as positive or negative, DE had a sensitivity of 85% and a specificity of 94%. In a parallel in vitro study, 18 pairs of PSB specimens were collected from respiratory secretions inoculated with S. aureus. From each pair, one brush was processed as described above and the other was smeared on a glass slide prior to performance of QC. Using direct smear instead of cytocentrifuged preparation, slightly but significantly affected QC. Direct examination of cytospin slides is highly predictive of quantitative bacterial culture results, and provides rapid information regarding the Gram-stain morphology of the causative organisms. It may therefore guide initial therapy.
This article has been cited by other articles:
![]() |
J. Chastre and J.-Y. Fagon Ventilator-associated Pneumonia Am. J. Respir. Crit. Care Med., April 1, 2002; 165(7): 867 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ioanas, R. Ferrer, J. Angrill, M. Ferrer, and A. Torres Microbial investigation in ventilator-associated pneumonia Eur. Respir. J., April 1, 2001; 17(4): 791 - 801. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Duflo, B. Allaouchiche, R. Debon, F. Bordet, and D. Chassard An Evaluation of the Gram Stain in Protected Bronchoalveolar Lavage Fluid for the Early Diagnosis of Ventilator-Associated Pneumonia Anesth. Analg., February 1, 2001; 92(2): 442 - 447. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Mimoz, A. Karim, J. X. Mazoit, A. Edouard, S. Leprince, and P. Nordmann Gram staining of protected pulmonary specimens in the early diagnosis of ventilator-associated pneumonia Br. J. Anaesth., November 1, 2000; 85(5): 735 - 739. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. BLOT, B. RAYNARD, E. CHACHATY, C. TANCRÈDE, S. ANTOUN, and G. NITENBERG Value of Gram Stain Examination of Lower Respiratory Tract Secretions for Early Diagnosis of Nosocomial Pneumonia Am. J. Respir. Crit. Care Med., November 1, 2000; 162(5): 1731 - 1737. [Abstract] [Full Text] |
||||
![]() |
M. S. Niederman Bronchoscopy in Nonresolving Nosocomial Pneumonia Chest, April 1, 2000; 117(4_suppl_2): 212S - 218S. [Full Text] [PDF] |
||||
![]() |
D. WERMERT, C.-H. MARQUETTE, M.-C. COPIN, F. WALLET, A. FRATICELLI, P. RAMON, and A.-B. TONNEL Influence of Pulmonary Bacteriology and Histology on the Yield of Diagnostic Procedures in Ventilator-Acquired Pneumonia Am. J. Respir. Crit. Care Med., July 1, 1998; 158(1): 139 - 147. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. H. MERTENS, J. M. NAGLER, D. I. GALDERMANS, H. R. SLABBYNCK, B. WEISE, and D. COOLEN Quality Assessment of Protected Specimen Brush Samples by Microscopic Cell Count Am. J. Respir. Crit. Care Med., April 1, 1998; 157(4): 1240 - 1243. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |