Eur Respir J 1990; 3: 679-685
Copyright © ERS Journals Ltd 1990
Distribution of inhaled 99mtechnetium labelled ultrafine carbon particle aerosol (Technegas) in human lungs
TC Amis,
AB Crawford,
A Davison,
and
LA Engel
Using a gamma camera, we quantified the topographical intrapulmonary distribution of inhaled 100 ml boluses of Technegas (TG), an ultrafine dispersion of carbon aggregates labelled with 99mTc, and 133Xenon (Xe) in six seated, normal subjects, inhaling from residual volume (RV) and from within a 1 l volume range above functional residual capacity (FRC) at a flow less than 0.5 l.s-1. Following inspiration of air to total lung capacity (TLC) counts were recorded during a 20 s breathhold. Twenty min after administration of the final TG bolus (TGF) counts were again recorded (TG20). Upper (U), middle (M) and lower (L) zones, as well as central (C) and peripheral (P) regions were identified in each lung. The relative fractional concentration (Fr) of TG and Xe was calculated for all zones after RV and FRC boluses, using counts obtained during Xe equilibration. The U/M or U/L ratios for XeFr did not differ significantly from those for TGFr (paired t-test; p greater than 0.1). The P/C count ratio constitutes a penetration index, which for TG was 1.07 +/- 0.13 (mean +/- SD) that of Xe. After correction for radioactive decay, TG20 counts were no different from TGF counts. The results suggest that the intrapulmonary distribution and penetration of TG in normal lungs is no different from Xe and that stable deposition in the lung periphery makes TG suitable for multiple-view imaging of ventilation distribution.
This article has been cited by other articles:

|
 |

|
 |
 
B. Harris, D. Bailey, S. Miles, E. Bailey, K. Rogers, P. Roach, P. Thomas, M. Hensley, and G. G. King
Objective Analysis of Tomographic Ventilation-Perfusion Scintigraphy in Pulmonary Embolism
Am. J. Respir. Crit. Care Med.,
June 1, 2007;
175(11):
1173 - 1180.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Petersson, A. Sanchez-Crespo, S. A. Larsson, and M. Mure
Physiological imaging of the lung: single-photon-emission computed tomography (SPECT)
J Appl Physiol,
January 1, 2007;
102(1):
468 - 476.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Petersson, A. Sanchez-Crespo, M. Rohdin, S. Montmerle, S. Nyren, H. Jacobsson, S. A. Larsson, S. G. E. Lindahl, D. Linnarsson, R. W. Glenny, et al.
Physiological evaluation of a new quantitative SPECT method measuring regional ventilation and perfusion
J Appl Physiol,
March 1, 2004;
96(3):
1127 - 1136.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Pellegrino, A. Biggi, A. Papaleo, G. Camuzzini, J. R. Rodarte, and V. Brusasco
Regional expiratory flow limitation studied with Technegas in asthma
J Appl Physiol,
November 1, 2001;
91(5):
2190 - 2198.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H.-W. Chung and Y.-H. Huang
Fractal Analysis of Nuclear Medicine Images for the Diagnosis of Pulmonary Emphysema: Interpretations, Implications, and Limitations
Am. J. Roentgenol.,
April 1, 2000;
174(4):
1055 - 1059.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. G. KING, S. EBERL, C. M. SALOME, I. H. YOUNG, and A. J. WOOLCOCK
Differences in Airway Closure between Normal and Asthmatic Subjects Measured with Single-Photon Emission Computed Tomography and Technegas
Am. J. Respir. Crit. Care Med.,
December 1, 1998;
158(6):
1900 - 1906.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. T. Robertson, R. W. Glenny, D. Stanford, L. M. McInnes, D. L. Luchtel, and D. Covert
High-resolution maps of regional ventilation utilizing inhaled fluorescent microspheres
J Appl Physiol,
March 1, 1997;
82(3):
943 - 953.
[Abstract]
[Full Text]
[PDF]
|
 |
|
Copyright © 1990 by the European Respiratory Society.
|