ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Glerant, J. C.
Right arrow Articles by Moxham, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Glerant, J. C.
Right arrow Articles by Moxham, J.
Eur Respir J 2006; 27:334-342
Copyright ©ERS Journals Ltd 2006

Diaphragm electromyograms recorded from multiple surface electrodes following magnetic stimulation

J. C. Glerant, N. Mustfa, W. D. Man, Y. M. Luo, G. Rafferty, M. I. Polkey and J. Moxham

Respiratory Muscle Laboratory, King's College London School of Medicine, King's College Hospital, London, UK.

CORRESPONDENCE: J. Moxham, Dept of Respiratory Medicine, King's College Hospital, Bessemer Road, London, SE5 9PJ, UK. Fax: 44 2073463589. E-mail: john.moxham{at}kingsch.nhs.uk

Keywords: Diaphragm, magnetic stimulation, reproducibility, surface electrodes

Received: March 11, 2005
Accepted November 3, 2005

The diaphragm compound-muscle action potential (CMAPdi), elicited by unilateral magnetic stimulation (UMS) of the phrenic nerve can be recorded using surface electrodes. However, there is no consensus on the best positioning of surface electrodes and there are no data on the reproducibility of the signal.

Using 36 surface electrode pairs, in five healthy subjects, the CMAPdi elicited by UMS and electrical stimulation (ES) were compared and 12 pairs were identified as providing acceptable signals. The latency and amplitude were measured for each CMAPdi, following UMS at 60–100% of maximal stimulator output, in 12 healthy subjects, on two occasions.

Latencies obtained using UMS and ES ranged between 6.1–7.33 and 6.25–7.17 ms, respectively. Optimum CMAPdi were not recorded from the same electrode pair in all subjects, or for both hemidiaphragms in each subject. However, the optimal recording site for a particular individual remained unchanged on subsequent testing. When recorded from the optimal site, latencies and amplitudes of CMAPdi elicited on the two occasions were not significantly different.

The current study suggests that the use of multiple chest wall electrodes can identify an optimal electrode pair, from which it is possible to obtain reproducible compound-muscle action potential signals.




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
E. Z. Ross, A. V. Nowicky, and A. K. McConnell
Influence of acute inspiratory loading upon diaphragm motor-evoked potentials in healthy humans
J Appl Physiol, May 1, 2007; 102(5): 1883 - 1890.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the European Respiratory Society.