ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zanen, P.
Right arrow Articles by van den Bosch, J.M.M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zanen, P.
Right arrow Articles by van den Bosch, J.M.M.
Eur Respir J 2001; 18:764-769
Copyright ©ERS Journals Ltd 2001


Reference values for alveolar membrane diffusion capacity and pulmonary capillary blood volume

P. Zanen1, I. van der Lee1, T. van der Mark2 and J.M.M. van den Bosch1

1 Dept of Pulmonary Diseases, St Antonius Hospital, Nieuwegein, 2 Dept of Pulmonary Diseases, University Hospital Groningen, Groningen, the Netherlands

CORRESPONDENCE: P. Zanen, Dept of Pulmonary Diseases, St Antonius Hospital, Koekoekslaan 1, Nieuwegein, The Netherlands. Fax: 31 306052001

Keywords: Membrane diffusion, pulmonary capillary volume, reference values

Received: March 28, 2001
Accepted June 30, 2001

The reference values for diffusion capacity of the alveolar capillary membrane (Tm,CO) and pulmonary capillary volume (Qc) are scarce, while the standard deviations of the equations are large. New equations and residual standard deviations (RSDs) were determined in a sample of healthy subjects.

Tm,CO and Qc values were measured in 117 (72 females, 45 males) nonsmoking healthy subjects. The carbon monoxide transfer factor (TL,CO) was determined when the volunteer was breathing room air and subsequently, when the volunteer was breathing 100% oxygen. From these data, Tm,CO and Qc values were calculated.

The females' TL,CO was 3.15 mmol·min–1·kPa–1 lower than the males', apparently caused by lower female lung volume. Tm,CO and Qc were lower in females, but correction for lung volume eliminated this difference. Qc–1 reference equations for females and males, respectively, are 4.375x10–2–1.085x10–2xheight and 4.455x10–2–1.085x10–2xheight (RSD for both sexes: 2.544x10–3). Tm,Co–l reference equations for females and males, respectively, are 0.111+3.304x10–4xage–4.753x10–2xheight and 0.127+3.304x10–4xage–4.753x10–2xheight (RSD for both sexes: 1.085x10–2). The general character of these equations complies with earlier publications, the only difference being that the RSDs are 1.18–2.76 times lower.

New reference equations for diffusion capacity of the alveolar capillary membrane and pulmonary capillary volume are available with considerably smaller residual standard deviations.




This article has been cited by other articles:


Home page
Eur Respir JHome page
B. Aguilaniu, J. Maitre, S. Glenet, A. Gegout-Petit, and H. Guenard
European reference equations for CO and NO lung transfer
Eur. Respir. J., May 1, 2008; 31(5): 1091 - 1097.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
H. Normand, F. Lavigne, and A. Mouadil
Performing the apnea of the single-breath carbon monoxide diffusing capacity: relaxation on the shutter or full inspiration with near atmospheric intrapulmonary pressure?
Chest, July 1, 2006; 130(1): 207 - 213.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. S. Zavorsky and J. M. Murias
A small amount of inhaled nitric oxide does not increase lung diffusing capacity
Eur. Respir. J., June 1, 2006; 27(6): 1251 - 1257.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
I. van der Lee, P. Zanen, J. C. Grutters, R. J. Snijder, and J. M.M. van den Bosch
Diffusing capacity for nitric oxide and carbon monoxide in patients with diffuse parenchymal lung disease and pulmonary arterial hypertension.
Chest, February 1, 2006; 129(2): 378 - 383.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
I. van der Lee, P. Zanen, and G. S. Zavorsky
Diffusion Capacity for Nitric Oxide and Carbon Monoxide
Chest, November 1, 2004; 126(5): 1708 - 1710.
[Full Text] [PDF]


Home page
Eur Respir JHome page
H. Normand, C. Marie, and A. Mouadil
Single-breath transfer factor in young healthy adults: 21% or 17.5% inspired oxygen?
Eur. Respir. J., June 1, 2004; 23(6): 927 - 931.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the European Respiratory Society.