ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ficker, J.
Right arrow Articles by Hahn, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ficker, J.
Right arrow Articles by Hahn, E.
Eur Respir J 2000; 16: 914-920
Copyright © ERS Journals Ltd 2000


Clinical Trial

An auto-continuous positive airway pressure device controlled exclusively by the forced oscillation technique

JH Ficker, FS Fuchs, GH Wiest, G Asshoff, AH Schmelzer, and EG Hahn

The forced oscillation technique (FOT) has been demonstrated to be a very sensitive tool for the assessment of upper airway obstruction during nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA). The present study was designed to evaluate the therapeutic efficacy of a novel auto-CPAP device based exclusively on the FOT. Following manual CPAP titration, 18 patients with OSA (mean apnoea/hypopnoea index (AHI) 48.0+/-28.1) were allocated to conventional CPAP and auto-CPAP treatment under polysomnographic control in randomized order. The patients were asked to assess their subjective daytime sleepiness using the Epworth Sleepiness Scale (ESS). The mean AHI during auto-CPAP treatment was 3.4+/-3.4 and was comparable with that obtained during conventional CPAP treatment (4.2+/-3.6). The analysis of sleep architecture, the arousal index (6.6+/-2.1 versus 7.3+/-4.4) or the ESS (5.6+/-1.8 versus 7.3+/-4.4) did not reveal any significant differences. However, the mean CPAP pressure during auto-CPAP treatment (0.84+/-0.26 kPa) and in particular the pressure applied in the lateral body position (0.74+/-0.35 kPa), was significantly lower than that employed in conventional CPAP treatment (0.93+/-0.16 kPa, both comparisons: p<0.05). The auto-continuous positive airway pressure device proved equally as effective as conventional continuous positive airway pressure. However, the mean treatment pressure was significantly reduced, especially when patients were sleeping in the lateral position.


This article has been cited by other articles:


Home page
ERRHome page
D. Pevernagie, J. F. Masa, J. C. Meurice, R. Farre, O. Marrone, and D. Rodenstein
Treatment of obstructive sleep-disordered breathing with positive airway pressure systems
Eur. Respir. Rev., December 1, 2007; 16(106): 125 - 131.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
A. T. Mulgrew, N. Fox, N. T. Ayas, and C. F. Ryan
Diagnosis and Initial Management of Obstructive Sleep Apnea without Polysomnography: A Randomized Validation Study
Ann Intern Med, February 6, 2007; 146(3): 157 - 166.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
G. Nilius, A. Happel, U. Domanski, and K.-H. Ruhle
Pressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure: A Comparison of Efficacy and Compliance.
Chest, October 1, 2006; 130(4): 1018 - 1024.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. Rigau, J. M. Montserrat, H. Wohrle, D. Plattner, M. Schwaibold, D. Navajas, and R. Farre
Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
Chest, August 1, 2006; 130(2): 350 - 361.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. A. Pevernagie, P. M. Proot, K. B. Hertegonne, M. C. Neyens, K. P. Hoornaert, and R. A. Pauwels
Efficacy of Flow- vs Impedance-Guided Autoadjustable Continuous Positive Airway Pressure: A Randomized Cross-over Trial
Chest, July 1, 2004; 126(1): 25 - 30.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. Farre, J. M. Montserrat, J. Rigau, X. Trepat, P. Pinto, and D. Navajas
Response of Automatic Continuous Positive Airway Pressure Devices to Different Sleep Breathing Patterns: A Bench Study
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 469 - 473.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the European Respiratory Society.