Eur Respir J 2000; 16: 914-920
Copyright © ERS Journals Ltd 2000
An auto-continuous positive airway pressure device controlled exclusively by the forced oscillation technique
JH Ficker,
FS Fuchs,
GH Wiest,
G Asshoff,
AH Schmelzer,
and
EG Hahn
The forced oscillation technique (FOT) has been demonstrated to be a very sensitive tool for the assessment of upper airway obstruction during nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA). The present study was designed to evaluate the therapeutic efficacy of a novel auto-CPAP device based exclusively on the FOT. Following manual CPAP titration, 18 patients with OSA (mean apnoea/hypopnoea index (AHI) 48.0+/-28.1) were allocated to conventional CPAP and auto-CPAP treatment under polysomnographic control in randomized order. The patients were asked to assess their subjective daytime sleepiness using the Epworth Sleepiness Scale (ESS). The mean AHI during auto-CPAP treatment was 3.4+/-3.4 and was comparable with that obtained during conventional CPAP treatment (4.2+/-3.6). The analysis of sleep architecture, the arousal index (6.6+/-2.1 versus 7.3+/-4.4) or the ESS (5.6+/-1.8 versus 7.3+/-4.4) did not reveal any significant differences. However, the mean CPAP pressure during auto-CPAP treatment (0.84+/-0.26 kPa) and in particular the pressure applied in the lateral body position (0.74+/-0.35 kPa), was significantly lower than that employed in conventional CPAP treatment (0.93+/-0.16 kPa, both comparisons: p<0.05). The auto-continuous positive airway pressure device proved equally as effective as conventional continuous positive airway pressure. However, the mean treatment pressure was significantly reduced, especially when patients were sleeping in the lateral position.
This article has been cited by other articles:

|
 |

|
 |
 
D. Pevernagie, J. F. Masa, J. C. Meurice, R. Farre, O. Marrone, and D. Rodenstein
Treatment of obstructive sleep-disordered breathing with positive airway pressure systems
Eur. Respir. Rev.,
December 1, 2007;
16(106):
125 - 131.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. T. Mulgrew, N. Fox, N. T. Ayas, and C. F. Ryan
Diagnosis and Initial Management of Obstructive Sleep Apnea without Polysomnography: A Randomized Validation Study
Ann Intern Med,
February 6, 2007;
146(3):
157 - 166.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Nilius, A. Happel, U. Domanski, and K.-H. Ruhle
Pressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure: A Comparison of Efficacy and Compliance.
Chest,
October 1, 2006;
130(4):
1018 - 1024.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Rigau, J. M. Montserrat, H. Wohrle, D. Plattner, M. Schwaibold, D. Navajas, and R. Farre
Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
Chest,
August 1, 2006;
130(2):
350 - 361.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. A. Pevernagie, P. M. Proot, K. B. Hertegonne, M. C. Neyens, K. P. Hoornaert, and R. A. Pauwels
Efficacy of Flow- vs Impedance-Guided Autoadjustable Continuous Positive Airway Pressure: A Randomized Cross-over Trial
Chest,
July 1, 2004;
126(1):
25 - 30.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Farre, J. M. Montserrat, J. Rigau, X. Trepat, P. Pinto, and D. Navajas
Response of Automatic Continuous Positive Airway Pressure Devices to Different Sleep Breathing Patterns: A Bench Study
Am. J. Respir. Crit. Care Med.,
August 15, 2002;
166(4):
469 - 473.
[Abstract]
[Full Text]
[PDF]
|
 |
|
Copyright © 2000 by the European Respiratory Society.
|