ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frey, U
Right arrow Articles by Bates, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frey, U
Right arrow Articles by Bates, J
Eur Respir J 2000; 16: 731-740
Copyright © ERS Journals Ltd 2000


Consensus Development Conference

Specifications for equipment used for infant pulmonary function testing. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing. European Respiratory Society/ American Thoracic Society

U Frey, J Stocks, A Coates, P Sly, and J Bates

The aim of this position paper is to define minimal performance criteria for the separate items comprising equipment used to measure respiratory function in infants together with overall performance criteria for the assembled pieces of such equipment. These guidelines cover numerous aspects including: 1) safety, 2) documentation and maintenance of equipment, 3) physical characteristics of mechanical parts and signal transducers, and 4) data acquisition. Further, validation procedures for individual components as well as for the integrated equipment are recommended. Adherence to these guidelines should ensure that infant lung function measurements can be performed with an acceptable degree of safety, precision and reproducibility. They will also facilitate multicentre collection of data and performance of clinical investigations. Manufacturers of infant respiratory function equipment should make every effort to comply with these guidelines, which represent the current standards of paediatric health professionals in this field.


This article has been cited by other articles:


Home page
ThoraxHome page
P. Latzin, C. Thamrin, and R. Kraemer
Ventilation inhomogeneities assessed by the multibreath washout (MBW) technique
Thorax, February 1, 2008; 63(2): 98 - 99.
[Full Text] [PDF]


Home page
ChestHome page
L. Loland and H. Bisgaard
Feasibility of Repetitive Lung Function Measurements by Raised Volume Rapid Thoracoabdominal Compression During Methacholine Challenge in Young Infants
Chest, January 1, 2008; 133(1): 115 - 122.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
S. Broughton, M. R Thomas, L. Marston, S. A Calvert, N. Marlow, J. L Peacock, G. F Rafferty, and A. Greenough
Very prematurely born infants wheezing at follow-up: lung function and risk factors
Arch. Dis. Child., September 1, 2007; 92(9): 776 - 780.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
M R Thomas, L Marston, G F Rafferty, S Calvert, N Marlow, J L Peacock, and A Greenough
Respiratory function of very prematurely born infants at follow up: influence of sex
Arch. Dis. Child. Fetal Neonatal Ed., May 1, 2006; 91(3): F197 - F201.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement: Raised Volume Forced Expirations in Infants: Guidelines for Current Practice
Am. J. Respir. Crit. Care Med., December 1, 2005; 172(11): 1463 - 1471.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
G. Hulskamp and J. Stocks
Progressive Decline in FRC in Infants: Physiology or Technology?
Am. J. Respir. Crit. Care Med., December 1, 2005; 172(11): 1475a - 1476.
[Full Text] [PDF]


Home page
CMAJHome page
Diagnosis of asthma
Can. Med. Assoc. J., September 13, 2005; 173(6_suppl): S15 - S19.
[Full Text] [PDF]


Home page
ChestHome page
N. Katier, C. S. P. M. Uiterwaal, B. M. de Jong, J. L. L. Kimpen, and C. K. van der Ent
Feasibility and Variability of Neonatal and Infant Lung Function Measurement Using the Single Occlusion Technique
Chest, September 1, 2005; 128(3): 1822 - 1829.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. N. Baldwin, B. Suki, J. J. Pillow, H. L. Roiha, S. Minocchieri, and U. Frey
Effect of sighs on breathing memory and dynamics in healthy infants
J Appl Physiol, November 1, 2004; 97(5): 1830 - 1839.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. Frey, C. Kuehni, H. Roiha, M. Cernelc, B. Reinmann, J. H. Wildhaber, and G. L. Hall
Maternal Atopic Disease Modifies Effects of Prenatal Risk Factors on Exhaled Nitric Oxide in Infants
Am. J. Respir. Crit. Care Med., August 1, 2004; 170(3): 260 - 265.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J.J. Pillow, H. Ljungberg, G. Hulskamp, and J. Stocks
Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer
Eur. Respir. J., May 1, 2004; 23(5): 763 - 768.
[Abstract] [Full Text] [PDF]


Home page
NeoReviewsHome page
H. B. Panitch
The Role of Pulmonary Function Testing in Infants
NeoReviews, May 1, 2004; 5(5): e183 - e185.
[Full Text] [PDF]


Home page
Eur Respir JHome page
S.C. Ranganathan, I. Goetz, A-F. Hoo, S. Lum, R. Castle, J. Stocks, and and the London Collaborative Cystic Fibrosis Group
Assessment of tidal breathing parameters in infants with cystic fibrosis
Eur. Respir. J., November 1, 2003; 22(5): 761 - 766.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
G. Hulskamp, A.-f. Hoo, H. Ljungberg, S. Lum, J. J. Pillow, and J. Stocks
Progressive Decline in Plethysmographic Lung Volumes in Infants: Physiology or Technology?
Am. J. Respir. Crit. Care Med., October 15, 2003; 168(8): 1003 - 1009.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
Statement on the Care of the Child with Chronic Lung Disease of Infancy and Childhood
Am. J. Respir. Crit. Care Med., August 1, 2003; 168(3): 356 - 396.
[Full Text] [PDF]


Home page
Eur Respir JHome page
P.J.F.M. Merkus, H.G.M. Arets, T. Joosten, A. Siero, M. Brouha, J.Y. Mijnsbergen, J.C. de Jongste, and C.K. van der Ent
Measurements of interrupter resistance: reference values for children 3-13 yrs of age
Eur. Respir. J., October 1, 2002; 20(4): 907 - 911.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
A. Schibler, G.L. Hall, F. Businger, B. Reinmann, J.H. Wildhaber, M. Cernelc, and U. Frey
Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants
Eur. Respir. J., October 1, 2002; 20(4): 912 - 918.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A.-F. Hoo, C. Dezateux, J. P. Hanrahan, T. J. Cole, R. S. Tepper, and J. Stocks
Sex-Specific Prediction Equations for VmaxFRC in Infancy . A Multicenter Collaborative Study
Am. J. Respir. Crit. Care Med., April 15, 2002; 165(8): 1084 - 1092.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. L. Hall, B. Reinmann, J. H. Wildhaber, and U. Frey
Tidal exhaled nitric oxide in healthy, unsedated newborn infants with prenatal tobacco exposure
J Appl Physiol, January 1, 2002; 92(1): 59 - 66.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G.L. Hall, J.H. Wildhaber, M. Cernelc, and U. Frey
Evaluation of the interrupter technique in healthy, unsedated infants
Eur. Respir. J., December 1, 2001; 18(6): 982 - 988.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
P. J. F. M. MERKUS, J. Y. MIJNSBERGEN, W. C. J. HOP, and J. C. de JONGSTE
Interrupter Resistance in Preschool Children . Measurement Characteristics and Reference Values
Am. J. Respir. Crit. Care Med., May 1, 2001; 163(6): 1350 - 1355.
[Abstract] [Full Text]


Home page
Eur Respir JHome page
U. Frey, B. Reinmann, and J. Stocks
The infant lung function model: a mechanical analogue to test infant lung function equipment
Eur. Respir. J., April 1, 2001; 17(4): 755 - 764.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
B. Reinmann, J. Stocks, and U. Frey
Assessment of an infant whole-body plethysmograph using an infant lung function model
Eur. Respir. J., April 1, 2001; 17(4): 765 - 772.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
I. Goetz, A.F. Hoo, S. Lum, and J. Stocks
Assessment of passive respiratory mechanics in infants: double versus single occlusion?
Eur. Respir. J., March 1, 2001; 17(3): 449 - 455.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.G. Morris, P. Gustafsson, R. Tepper, M. Gappa, and J. Stocks
The bias flow nitrogen washout technique for measuring the functional residual capacity in infants
Eur. Respir. J., March 1, 2001; 17(3): 529 - 536.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J. Stocks, S. Godfrey, C. Beardsmore, E. Bar-Yishay, and R. Castile
Plethysmographic measurements of lung volume and airway resistance
Eur. Respir. J., February 1, 2001; 17(2): 302 - 312.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. Schmalisch, B. Foitzik, R.R. Wauer, and J. Stocks
In vitro assessment of equipment and software to assess tidal breathing parameters in infants
Eur. Respir. J., January 1, 2001; 17(1): 100 - 107.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. Schmalisch, B. Foitzik, R.R. Wauer, and J. Stocks
Effect of apparatus dead space on breathing parameters in newborns: "flow-through" versus conventional techniques
Eur. Respir. J., January 1, 2001; 17(1): 108 - 114.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M. Gappa, A.A. Colin, I. Goetz, and J. Stocks
Passive respiratory mechanics: the occlusion techniques
Eur. Respir. J., January 1, 2001; 17(1): 141 - 148.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Cernelc, B. Suki, B. Reinmann, G. L. Hall, and U. Frey
Correlation properties of tidal volume and end-tidal O2 and CO2 concentrations in healthy infants
J Appl Physiol, May 1, 2002; 92(5): 1817 - 1827.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the European Respiratory Society.