Eur Respir J 2000; 16: 472-475
Copyright © ERS Journals Ltd 2000
Observer variability of lung function measurements in 2-6-yr-old children
B Klug,
KG Nielsen,
and
H Bisgaard
The aim of this study was to assess the within-observer and between-observer variability of lung function measurements in children aged 2-6 yrs. Two observers examined 22 asthmatic children independently according to a predefined protocol. Each observer obtained duplicate measurements of respiratory resistance by the interrupter technique (Rint), respiratory resistance (Rrs,5) and reactance (Xrs,5) at 5 Hz by the impulse oscillation technique and the specific airway resistance (sRaw) by whole body plethysmography. The within-subject SD (SDw) was not significantly different in the two observers. The ratio SDw between observers/mean SDw within observers was 0.94, 1.25, 1.35 and 2.86 for Xrs,5, Rrs,5, sRaw and Rint, respectively, indicating greater between-observer variability of the latter. The systematic difference between observers assessed by the difference between observer means (expressed as a percentage of their mean value) was 11, 7, 6 and 2% for Xrs,5, sRaw, Rrs,5 and Rint, respectively. These differences were statistically significant, except that for Rint. In conclusion, specific airway resistance, impulse oscillation technique and respiratory resistance assessed by the interrupter technique measurements in young children are subject to influence by the observer, and the random variability between observers appears to be particularly great for respiratory resistance assessed by the interrupter technique. The authors suggest that the between-observer variability should be investigated when evaluating novel methods for testing lung function.
This article has been cited by other articles:

|
 |

|
 |
 
P. Poorisrisak, C. Vrang, J. M. Henriksen, B. Klug, B. Hanel, and H. Bisgaard
Accuracy of Whole-Body Plethysmography Requires Biological Calibration
Chest,
June 1, 2009;
135(6):
1476 - 1480.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Gupta, M. McKean, and A. B Chang
Management of chronic non-specific cough in childhood: an evidence-based review
Arch. Dis. Child. Ed. Pract.,
April 1, 2007;
92(2):
33 - 39.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M R Thomas, G F Rafferty, R Blowes, J L Peacock, N Marlow, S Calvert, A Milner, and A Greenough
Plethysmograph and interrupter resistance measurements in prematurely born young children
Arch. Dis. Child. Fetal Neonatal Ed.,
May 1, 2006;
91(3):
F193 - F196.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. B. Chang and W. B. Glomb
Guidelines for Evaluating Chronic Cough in Pediatrics: ACCP Evidence-Based Clinical Practice Guidelines
Chest,
January 1, 2006;
129(1_suppl):
260S - 283S.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Diagnosis of asthma
Can. Med. Assoc. J.,
September 13, 2005;
173(6_suppl):
S15 - S19.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Bisgaard and K. G. Nielsen
Plethysmographic Measurements of Specific Airway Resistance in Young Children
Chest,
July 1, 2005;
128(1):
355 - 362.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. A. Straub, S. Minocchieri, A. Moeller, J. Hamacher, and J. H. Wildhaber
The Effect of Montelukast on Exhaled Nitric Oxide and Lung Function in Asthmatic Children 2 to 5 Years Old
Chest,
February 1, 2005;
127(2):
509 - 514.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R M J Beelen, H A Smit, R T van Strien, L P Koopman, J E Brussee, B Brunekreef, J Gerritsen, and P J F M Merkus
Short and long term variability of the interrupter technique under field and standardised conditions in 3-6 year old children
Thorax,
September 1, 2003;
58(9):
761 - 764.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C.S. Pao, P.D. Bridge, and S.A. McKenzie
Not all laboratories are alike
Eur. Respir. J.,
May 1, 2001;
17(5):
1054 - 1054.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. Klug, K.G. Nielsen, and H. Bisgaard
From the Authors
Eur. Respir. J.,
May 1, 2001;
17(5):
1054 - 1054.
[Full Text]
[PDF]
|
 |
|
Copyright © 2000 by the European Respiratory Society.
|