ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van der Veen, M.
Right arrow Articles by van der Zee, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van der Veen, M.
Right arrow Articles by van der Zee, J.
Eur Respir J 1999; 13: 668-672
Copyright © ERS Journals Ltd 1999


Clinical Trial

Aerosol recovery from large-volume reservoir delivery systems is highly dependent on the static properties of the reservoir

MJ van der Veen and JS van der Zee

In this study, the role of electrostatic fields on aerosol recovery from a system with a large collapsible reservoir (30 L) was investigated. In addition, the efficacy of the reservoir method for bronchial challenge procedures was assessed in vivo. Aerosol recovery was determined by measuring the fraction of aerosol (0.05% 99mTc-tagged human albumin solution) retrieved from the reservoir. Before aerosol recovery experiments, electrostatic fields in the reservoir were measured. Aerosol recovery varied significantly with wall thickness of the reservoir and presence of an antistatic coating (range 6.0-70.3%). A close inverse relationship was found between the mean electrostatic field in the reservoir and aerosol recovery. The nebulized provocative concentration of histamine causing a 20% fall in forced expiratory volume in one second in asthmatics was found to be approximately half that of a standard method when compared with the reservoir system (mean ratio 2.24 (95% confidence interval, 1.60-3.12)). Recovery from an aerosol delivery system with a relatively large collapsible aerosol reservoir was highly dependent on the electrostatic field in the reservoir. In these systems the use of electrostatic field dissipative material for the reservoir is therefore recommended.


This article has been cited by other articles:


Home page
Eur Respir JHome page
N. A. Maris, M. C. Dessing, A. F. de Vos, P. Bresser, J. S. van der Zee, H. M. Jansen, C. A. Spek, and T. van der Poll
Toll-like receptor mRNA levels in alveolar macrophages after inhalation of endotoxin.
Eur. Respir. J., September 1, 2006; 28(3): 622 - 626.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. A. Maris, A. F. de Vos, M. C. Dessing, C. A. Spek, R. Lutter, H. M. Jansen, J. S. van der Zee, P. Bresser, and T. van der Poll
Antiinflammatory Effects of Salmeterol after Inhalation of Lipopolysaccharide by Healthy Volunteers
Am. J. Respir. Crit. Care Med., October 1, 2005; 172(7): 878 - 884.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the European Respiratory Society.